Kino Flo 4ft Double (Fluorescent)

Last Updated 1 week ago

Overview

Kino Flo 4ft Double lighting fixture

The Kino Flo 4ft Double, CFX-4802, is a narrow two-lamp fluorescent softlight with a remote ballast. Its long, slim surface is useful for a soft edge, a low-profile key, fill in a confined space or a controlled reflection on a product. It occupies less width than a four-lamp 4Bank while preserving the four-foot source length.

This is the fluorescent Double system, not an LED tube pair mounted in an old Kino shell. The detachable harness, correct lamps, mounting plate, extension cable and ballast make up the working light. A head-only sale omits much of the equipment needed to reproduce its documented behaviour.

Key specifications

SpecificationDetails
Fixture code / lamp countCFX-4802; two lamps
Lamp typeF75/T12, four-foot True Match fluorescent tubes
Colour examples488-K32-S / KF32 and 488-K55-S / KF55
Dimensions52 × 7½ × 3½ inches; 6-inch barn doors, original catalogue
Fixture mass with lamps7.7 lb / 3.5 kg; ballast and kit weight are separate
MountTwist-lock plate; 3/8-inch grip-head pin or appropriate 16 mm receiver version
CableX09 Double extension family; 25 ft system extension
Older ballast exampleBAL-210 Select/Ve, 120 V; F75 rating 2.4 A in archival catalogue
Later universal exampleBAL-227, 100–240 V; F75 figures 1.3 A at 120 V / 0.7 A at 230 V in the 2017 manual
Output frequency25 kHz for the documented electronic ballast versions
Level selectionOne or two lamps; 4ft/2ft output setting as documented
Diffusion accessoriesDFS-4802 full or half Flozier; matching louver
Harness designRemovable harness, reflector and louver; use only the documented compatible system
Kino Flo’s original catalogue and model-family operating manual. Historical fixture and ballast revisions are identified separately.

Strengths and limitations

Strengths

  • A bank of fluorescent tubes provides a broad close source.
  • The established modifier and mounting system supports fast setup.

Limitations

  • Lamp type, age and ballast configuration affect colour and output.
  • Inspect older connectors, lamp holders and ballast cabling before use.

Practical uses

The Double can run along a wall, sit above a narrow opening or create an elongated reflection without the width of a 4Bank. For a face close to the lamp, its four-foot dimension can create a soft transition in one direction while the narrower dimension retains more shape. Rotation and distance are useful creative controls, not merely mounting conveniences.

It can also serve as a modest edge or fill when a larger source produces too much spill. The tube pattern may show in reflective objects or close-up eyes. Use the correct diffusion sleeve when a smoother visible surface is needed, and check the reflection itself rather than relying only on the source’s overall brightness.

SetupWorking approach
Close interview keySet lamp arrangement and diffusion, then check white balance through the camera.
Reflection or fillOrient the bank for the required highlight and control spill with the correct louver.
Lighting setups

Back to contents

Output and colour

The original Kino Flo catalogue publishes the following four-foot Double readings. They describe that catalogue’s fluorescent configuration, not an LED-retrofitted shell or a guarantee for every later ballast generation. Lamp condition, operating temperature, louver, diffusion and ballast selection can change the delivered level.

DistanceCentre illuminance
4 ft / 1.22 m94 fc
6 ft / 1.83 m45 fc
8 ft / 2.44 m26 fc
10 ft / 3.05 m17 fc
Manufacturer foot-candles at the stated imperial distances; 1 fc ≈ 10.764 lux. Measure the actual working system after warm-up.

Switching from two lamps to one reduces the emitting area as well as level. That can change a product reflection or the direction of the source’s centre. Position the light and choose the active lamp deliberately when the shot is sensitive to reflections or a precise edge.

The normal selector position for four-foot tubes is 4ft. Kino describes using 2ft mode on four-foot lamps in certain hot or restricted-airflow conditions to reduce a colour-temperature and green-spike problem, at roughly half a stop less exposure. Keep cooling paths open regardless. The switch is not a calibrated CCT dial, and dimming the mains is not an approved way to obtain a smooth fade.

Back to contents

Power and batteries

The original Select/Ve catalogue lists 2.4 A at 120 V for F75 operation. The later universal BAL-227 manual lists 1.3 A at 120 V for its F75 configuration. Those are not two interchangeable estimates for the same unidentified box. Inspect the supplied ballast and use its rating when planning the package.

A universal BAL-227 accepts 100–240 V, while older Select versions can be dedicated to a regional supply. The tube wattage does not by itself establish mains watts or current, and a physically similar fluorescent tube is not proof of compatible colour or drive. Use the correct matched Kino lamp type and harness system.

Control, cooling and camera operation

Inspect the shell, reflector, louver, tube clips, harness end connectors, cable locking rings and centre plate. Test both lamp channels, cold starting and operation over the complete intended cable length. Look for worn contacts or insulation and have electrical defects serviced before use.

Match lamps for colour, condition and age where possible. Allow the system to stabilise before judging its output, and test high-speed or unusual-shutter work with the actual ballast and camera. ‘Flicker-free’ in an old catalogue is not a universal guarantee across every recording condition. Confirm replacement-tube availability and use proper transport cases and lamp recycling procedures.

Back to contents

Modifiers, rigging and the working package

The removable harness is one reason classic Kino fixtures remain adaptable. It allows the lamps to be used in documented configurations outside the shell, but it does not remove the need for protected lamps, suitable support and the manufacturer’s electrical precautions. Do not connect or disconnect lamp ends, harnesses or extensions with the ballast energised.

Use the Double’s X09 cable family and appropriate locking connectors, not an audio cable or a guessed pin-compatible substitute. The system manual documents remote operation up to 75 ft using its prescribed extensions. Check the mounting plate’s locking pin and the correct secondary suspension when hanging the head, and keep the ballast and cable weight from pulling on the fixture.

Back to contents

Alternatives and related fixtures

A four-foot 4Bank supplies more output and a wider source. A two-foot Double fits tighter spaces but gives less long-axis coverage. Modern LED tubes can provide colour and wireless control, but a conversion must use the replacement system’s approved wiring and power method. An LED-retrofitted Double should have its own specifications and photometrics, rather than inheriting the original fluorescent chart.

The original Double is a sensible working tool when the complete system is healthy and the narrow fluorescent source fits the image. It is less compelling as a purchase if several missing components or unreliable lamps have to be replaced before the first usable lighting test.

FixtureChoose it for
Kino Flo FreeStyle LEDA separate LED engine and controller system.
Kino Flo Diva-Lite LEDAn LED alternative with different colour modes and power hardware.
Related fixtures

Back to contents

What people are saying

The Substream: fluorescent-light overview

The Substream introduces Kino Flo fluorescent lighting. The overview gives family context; use the exact lamp, ballast and mounting specifications for this model. View the guide.

Videos

Kino Flo: fluorescent-light overview

A family guide to the fluorescent format.

Back to contents

Rental and used-fixture checks

Check the exact model and revision, complete power package, mounting hardware and control leads. Inspect lamp holders, protective glass and ballast connections. Test the intended operating level, fade and camera settings before rigging.

Documentation and specifications

Manufacturer operating manual, original manufacturer catalogue with photometrics, Kino Flo manual archive and photograph and rental-inventory source. Current lamp and service-part availability should be confirmed for the exact unit. Later-generation electrical figures are from the 2017 universal 4Bank/Double/Single manual.

Product photograph: Product image via Sanwa Group.

Back to contents