Kino Flo Flathead 80 (Fluorescent)

Last Updated 5 hours ago

Overview

Kino Flo Flathead 80 lighting fixture
Rear of the Flathead 80 with its centre mounting plate and attached cables.
Rear and mountRear of the Flathead 80 with its centre mounting plate and attached cables. Photo: 711rent.
Flathead 80 shown horizontally, with all eight fluorescent tube positions visible.
Front in landscapeFlathead 80 shown horizontally, with all eight fluorescent tube positions visible. Photo: Hand Held Films.

The Kino Flo Flathead 80 is an eight-lamp, four-foot fluorescent softlight designed to create a much larger emitting surface than a standard 4Bank. It uses two remote four-lamp ballast circuits, giving a broad source for keys, beauty work, overhead illumination and large-area fill without mounting the ballast weight directly behind the lamps.

The ’80’ is a model name, not an 80 W rating. This is the CFX-4808 fluorescent Flathead, not a shell converted to LED tubes. A complete system includes the fixture, eight matched lamps, appropriate mount, two compatible ballasts and two head cables.

Detail photo

  • Eight Four-Foot LampsCFX-4808; F75/T12 fluorescent system
  • Check Ballast RevisionDocumented pair: 10 A at 120 V / 5 A at 230 V
  • Two Remote BallastsSelect or Select/DMX 4Bank versions
  • Weight 27 lb / 12 kg Fixture. With lamps; mounts and ballasts additional
  • Individual Lamp SwitchingDMX ballast: five addresses each Catalogue configuration: 4,748 lux at 1 m.
  • IP Rating The cited manufacturer documentation does not establish a numeric rating; keep the fixture and power equipment dry. Read the IP rating guide.

Jump to Output Calculator ↓

Key Specifications

SpecificationDetails
Fixture / lampsCFX-4808; eight F75/T12 four-foot fluorescent lamps
Colour examplesKF29, KF32 or KF55 safety-coated lamps listed by Kino
Dimensions51 × 24 × 4 inches / 129 × 61 × 10 cm
Fixture weight with lamps27 lb / 12 kg in the Rev A manual dated 09-18-2013; older catalogue lists 26 lb
MountMTP-K81 twist-on centre mount with 28 mm / junior pin
Ballast arrangementTwo Select 4Bank or compatible Select/DMX 4Bank ballasts, four lamps each
Rev A BAL-415 / BAL-455 input figuresTwo × 5 A = 10 A at 120 V; two × 2.5 A = 5 A at 230 V
Older catalogue configurationTwo older ballasts: 9.2 A at 120 V; do not substitute ratings across revisions
ExtensionsTwo X16 4Bank runs; manufacturer documents up to 75 ft with specified extensions
Manual switchingFour individual lamp switches per ballast
Circuit arrangementConnector 1 operates four inner lamps; connector 2 operates four outer lamps
DMX ballast footprintFive addresses per documented 4Bank DMX ballast; verify the exact ballast chart
Normal output selector4ft for four-foot lamps; documented 2ft mode reduces output and affects operating colour
Included / matching controlsGel frame and louver; fit and generation must be checked
Kino Flo’s original catalogue and model-family operating manual. Historical fixture and ballast revisions are identified separately.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

Strengths

  • A bank of fluorescent tubes provides a broad close source.
  • The established modifier and mounting system supports fast setup.

Limitations

  • Lamp type, age and ballast configuration affect colour and output.
  • Inspect older connectors, lamp holders and ballast cabling before use.

Practical Uses

The broad lamp surface can create a wraparound key or a large overhead source while keeping electronic ballasts off the head. That makes the fixture different from a self-ballasted Image 85, even though both use eight four-foot tubes. Their mass, mounts, controls and package handling should not be merged.

The Flathead is useful when the source size matters more than compact transport. It can cover a face or group from nearby, illuminate a larger area or provide broad fill. Moving it further back reduces apparent size and level. If additional diffusion is used, check that the whole material is illuminated and allow for its output loss.

SetupWorking approach
Close interview keySet lamp arrangement and diffusion, then check white balance through the camera.
Reflection or fillOrient the bank for the required highlight and control spill with the correct louver.
Lighting setups

Back to contents

Output and Colour

The original catalogue provides the following Flathead readings. They apply to its documented fluorescent system. A later ballast or an LED conversion may produce different results, and a single centre reading does not describe uniformity across an entire diffusion frame or set.

DistanceCentre illuminance
1 m4,748 lux
2 m1,443 lux
3 m678 lux
4 m394 lux
Manufacturer catalogue values. Assess actual output after lamp warm-up and with the working louver or diffusion.

Back to contents

Power and Batteries

The Rev A manual dated 09-18-2013 specifies two BAL-415 or BAL-455 units and gives a combined 10 A at 120 V or 5 A at 230 V. The older catalogue gives different figures for its earlier ballast generation. A later rental package may carry other compatible ballasts; read those labels and manuals instead of assuming that every Flathead draws one fixed current.

The manual’s voltage-specific Select ballasts require their proper regional supply. Do not dim the mains with an SCR dimmer; the instructions call for a non-dim source. Keep the two ballast/cable circuits identified so an on-set fault can be traced without confusing which group of lamps is being driven.

Control, Cooling and Camera Operation

Connector 1 drives the four inner lamps and connector 2 the four outer lamps in the documented system. Switching individual lamps changes the luminous surface as well as level. That matters for reflections and shadow shape, particularly when the fixture is close to a glossy subject.

With the specified Select/DMX ballasts, each ballast uses five DMX addresses, including its lamp-length/output selection function. The two ballasts therefore need a deliberate patch; there is not one built-in RGB fixture personality in the head. The manual also explains that applied DMX disables manual controls unless the documented local-control arrangement is selected. Use the chart for the actual ballast revision.

Back to contents

Modifiers, Rigging and the Working Package

Match all eight tubes and keep airflow around them unobstructed. Kino describes using 2ft mode on four-foot lamps in some hot operating conditions to reduce a colour-temperature and green-spike problem, with approximately half a stop less level. It is an operating adjustment, not a calibrated tunable-white control.

Switch off the ballast before changing lamp, harness or extension connections. Use the correct X16 cable system and respect the manual’s maximum 75 ft arrangement. Inspect the junior mount’s lock and the fixture’s documented rigging points. The 27 lb figure is a lamped fixture value; add the mount, louver, frame, cables and any other working accessories to the load.

Back to contents

Alternatives and Related Fixtures

Check lamp holders, pins, all eight channels, both input circuits, cable locks, frame retainers, reflector and louver. Look for a warped body, damaged rigging hardware, brittle insulation or a mount that will not lock positively. Confirm that a sale includes two working ballasts and cables rather than pricing only the fluorescent shell.

High-frequency operation does not remove the need to test high-speed filming and unusual shutter settings. Protect tubes in transit and confirm replacement availability. An LED softlight may be easier for colour, fades and a smaller operating package, while the Flathead remains useful when a broad fluorescent source and an existing complete kit meet the scene’s requirements.

FixtureChoose it for
Kino Flo FreeStyle LEDA separate LED engine and controller system.
Kino Flo Diva-Lite LEDAn LED alternative with different colour modes and power hardware.
Related fixtures

Back to contents

What People Are Saying

Field Feedback Summary

These are practical takeaways from Kino Flo’s operating instructions and the model-specific documentation cited below, not independent owner reviews.

What worked

  • Kino assigns the inner four lamps to ballast 1 and the outer four to ballast 2: the two groups can be selected separately instead of treating it as one eight-lamp bank.
  • The corner cardholders accept foam-core panels, and the manual identifies screw points for flat set-wall mounting.
  • The designated extension runs permit remote ballast placement up to 75 ft (22.9 m), freeing space near the head for rigging.

Drawbacks to plan for

  • Plan for two 4Bank ballasts and two cable runs, not one eight-lamp connection; at the documented Rev A 120 V rating, the two ballasts total 10 A.
  • The 51 × 24 in head is 27 lb with lamps in the Rev A manual, excluding ballasts; use rated junior or approved set-wall support and account for both runs.
  • With the specified DMX ballasts, each ballast uses five addresses and a connected DMX line disables normal local control unless switched to the manual mode documented by Kino.

The Substream: Fluorescent-light Overview

The Substream introduces Kino Flo fluorescent lighting. The overview gives family context; use the exact lamp, ballast and mounting specifications for this model. View the guide.

Videos

Kino Flo: Fluorescent-light Overview

A family guide to the fluorescent format.

Back to contents

Rental and Used-fixture Checks

Count eight 4 ft tubes and two compatible 4Bank ballasts of the correct mains voltage. Verify that both head feeds and extensions are present, and test all eight lamps across the two banks before pickup. If the job needs wired dimmer-board control, confirm the Select/DMX ballasts rather than assuming ordinary Select units offer DMX. Check the harness locks and mark the installed lamp colour. Kino Flo Flathead 80 manual.

Documentation and Specifications

Manufacturer operating manual, original manufacturer catalogue with photometrics, Kino Flo manual archive and photograph and rental-inventory source. Current lamp and service-part availability should be confirmed for the exact unit.

Product photograph: Product image via Sanwa Group.

Back to contents