IP Ratings for Film Lights: Dust, Water and Real-World Limits

An IP code describes tested enclosure protection, not a blanket promise that a light is waterproof or safe in every location. Read both digits, identify which component is rated, and follow the manufacturer’s setup instructions.

Decode an IP Rating

First digit: solids and access. Second digit: water. Read the two results separately.

Use the digit lookup or all-combinations reference below. Both work without JavaScript.

A code describes tested protection, not permission to use a whole lighting system in water. Check test limits.

Before You Use It in the Rain

  • Check the rated component: a lamphead’s rating does not automatically cover its ballast, power supply or cables.
  • Check the complete enclosure: fit required covers and caps, and fully mate the specified connectors.
  • Check the manufacturer’s permitted use: follow the stated configuration, orientation and operating limits. An IP code is not permission to energize wet equipment.

Read the Two Digits

First digit: protection against access to hazardous parts and entry of solid foreign objects. It covers more than dust. Second digit: protection against harmful water ingress under the specified test.

X is not 0. X means that characteristic is not specified in the code; it is not a pass or a failure. A 0 means no protection is specified for that characteristic. For example, IPX4 gives a water classification but no solids classification. If a fixture’s documentation gives no IP code, say “not documented” rather than inventing IP20 or IP00. See Auer Signal’s manufacturer explanation.

What IP23 Means

2: protection against finger access to hazardous parts and solid objects 12.5 mm in diameter and larger. 3: water sprayed at angles up to 60° from vertical must not cause harmful effects under the test conditions. This is not dust-tightness, all-direction splash protection, jet resistance or immersion approval. UL’s code-authority reference identifies the finger/12.5 mm classification and separates spraying from splashing; Auer Signal explains the spray angle.

For a lamphead marked IP23, “limited spray protection under prescribed conditions” is more useful than “waterproof.” It does not establish a rating for its ballast, loose connectors or an assembled cable system.

Common Codes at a Glance

CodeSolids / Access SummaryWater Summary
IP20Finger access / objects ≥12.5 mmNo water protection specified.
IP23Finger access / objects ≥12.5 mmSpray within 60° of vertical under test conditions.
IP54Dust-protected, not dust-tightAll-direction splashes under test conditions.
IP65Dust-tightWater jets under the specified test.
IP66Dust-tightMore powerful water jets under the specified test.
IP67Dust-tightTemporary immersion under specified depth and duration.
IP68Dust-tightContinuous immersion under agreed conditions; check the product’s depth, duration and operating limits.
IP69Dust-tightHigh-pressure, high-temperature water-jet test; not automatic immersion approval.
Plain-English comparisons, not test specifications or permission to expose equipment. “Dust-protected” allows limited ingress that does not interfere with safe, satisfactory operation.

Mapping references: UL’s published IP guide and EAO’s manufacturer explanation. The current IEC 60529 framework includes water digit 9; do not substitute an older chart that ends at 8. IP69 and vehicle-standard IP69K terminology are not interchangeable test claims.

Immersion and Jets Are Different Tests

IP67 or IP68 does not automatically establish IP65 or IP66 jet protection. Look for an explicit combined rating when both are required. Likewise, a high-pressure water-jet rating does not establish immersion performance. EAO explains the separate tests and combined markings.

Check the Complete Lighting System

Treat the head, ballast or power supply, controller and connectors as separate components. Check the exact manual for mated connector requirements, approved cables, closed covers and port caps, orientation, ventilation and environmental limits. A rating on one enclosure is not inherited by every attached component.

Inspect seals and closures before use. Do not assume an old or damaged unit retains its specified protection. IP alone does not settle condensation, corrosion, saltwater, chemicals, impact resistance, electrical installation or hot-lamp handling. Follow the actual manufacturer instructions and production electrical-safety arrangements rather than choosing equipment by the largest IP number.

Complete Digit Lookup

Read each position independently. The first position accepts 0–6 or X; the second accepts 0–9 or X. These summaries describe tests and access protection, not exposure instructions. Water protection means avoiding harmful effects under the specified test, not necessarily preventing every drop.

First Digit: Solids and Access

DigitMeaning
0No solids or access protection assigned.
1Stops solid objects 50 mm or larger; back-of-hand access protection.
2Stops solid objects 12.5 mm or larger; finger-access protection.
3Stops solid objects 2.5 mm or larger; tool-access protection.
4Stops solid objects 1 mm or larger; wire-access protection.
5Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.
6Dust-tight under the test; wire-access protection.
XSolids/access digit omitted. No digit-based claim supplied.

Second Digit: Water

DigitMeaning
0No water protection assigned.
1Vertical dripping-water test.
2Dripping-water test with enclosure tilted up to 15°.
3Spray test up to 60° from vertical.
4Splash test from all directions.
5Water-jet test.
6Powerful-water-jet test.
7Temporary immersion test with specified depth and time.
8Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.
9High-pressure, high-temperature water-jet test.
XWater digit omitted. No water classification supplied.

Sources: UL’s IP classification guide, Auer Signal’s digit explanation, and IEC 60529 clauses 5–6. IPX7’s commonly quoted “1 m / 30 minutes” is shorthand: the actual test placement depends on enclosure dimensions. IPX8 is not an unlimited-depth promise.

All Two-Position Combinations

Show All 88 Combinations · Optional Reference

This matrix contains all 88 combinations of the two positions, including X. It is a notation decoder, not a list of certified products or a claim that every combination has been tested. Match the row’s solids digit with the column’s water digit. Each cell expands to its independent meanings without JavaScript. Row and column headings link to the lookup. On a phone, swipe the matrix sideways; each code can also be reached by keyboard. IPXX gives no information in either digit.

First digit down the left; second digit across the top. Expand a code for its meanings.
Solids ↓ / Water →0123456789X
0
IP00

Solids/access: No solids or access protection assigned.

Water: No water protection assigned.

IP01

Solids/access: No solids or access protection assigned.

Water: Vertical dripping-water test.

IP02

Solids/access: No solids or access protection assigned.

Water: Dripping-water test with enclosure tilted up to 15°.

IP03

Solids/access: No solids or access protection assigned.

Water: Spray test up to 60° from vertical.

IP04

Solids/access: No solids or access protection assigned.

Water: Splash test from all directions.

IP05

Solids/access: No solids or access protection assigned.

Water: Water-jet test.

IP06

Solids/access: No solids or access protection assigned.

Water: Powerful-water-jet test.

IP07

Solids/access: No solids or access protection assigned.

Water: Temporary immersion test with specified depth and time.

IP08

Solids/access: No solids or access protection assigned.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP09

Solids/access: No solids or access protection assigned.

Water: High-pressure, high-temperature water-jet test.

IP0X

Solids/access: No solids or access protection assigned.

Water: Water digit omitted. No water classification supplied.

1
IP10

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: No water protection assigned.

IP11

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Vertical dripping-water test.

IP12

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP13

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Spray test up to 60° from vertical.

IP14

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Splash test from all directions.

IP15

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Water-jet test.

IP16

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Powerful-water-jet test.

IP17

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Temporary immersion test with specified depth and time.

IP18

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP19

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: High-pressure, high-temperature water-jet test.

IP1X

Solids/access: Stops solid objects 50 mm or larger; back-of-hand access protection.

Water: Water digit omitted. No water classification supplied.

2
IP20

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: No water protection assigned.

IP21

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Vertical dripping-water test.

IP22

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP23

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Spray test up to 60° from vertical.

IP24

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Splash test from all directions.

IP25

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Water-jet test.

IP26

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Powerful-water-jet test.

IP27

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Temporary immersion test with specified depth and time.

IP28

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP29

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: High-pressure, high-temperature water-jet test.

IP2X

Solids/access: Stops solid objects 12.5 mm or larger; finger-access protection.

Water: Water digit omitted. No water classification supplied.

3
IP30

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: No water protection assigned.

IP31

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Vertical dripping-water test.

IP32

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP33

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Spray test up to 60° from vertical.

IP34

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Splash test from all directions.

IP35

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Water-jet test.

IP36

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Powerful-water-jet test.

IP37

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Temporary immersion test with specified depth and time.

IP38

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP39

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: High-pressure, high-temperature water-jet test.

IP3X

Solids/access: Stops solid objects 2.5 mm or larger; tool-access protection.

Water: Water digit omitted. No water classification supplied.

4
IP40

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: No water protection assigned.

IP41

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Vertical dripping-water test.

IP42

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP43

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Spray test up to 60° from vertical.

IP44

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Splash test from all directions.

IP45

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Water-jet test.

IP46

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Powerful-water-jet test.

IP47

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Temporary immersion test with specified depth and time.

IP48

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP49

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: High-pressure, high-temperature water-jet test.

IP4X

Solids/access: Stops solid objects 1 mm or larger; wire-access protection.

Water: Water digit omitted. No water classification supplied.

5
IP50

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: No water protection assigned.

IP51

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Vertical dripping-water test.

IP52

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP53

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Spray test up to 60° from vertical.

IP54

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Splash test from all directions.

IP55

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Water-jet test.

IP56

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Powerful-water-jet test.

IP57

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Temporary immersion test with specified depth and time.

IP58

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP59

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: High-pressure, high-temperature water-jet test.

IP5X

Solids/access: Dust-protected: limited dust may enter without impairing safe operation; wire-access protection.

Water: Water digit omitted. No water classification supplied.

6
IP60

Solids/access: Dust-tight under the test; wire-access protection.

Water: No water protection assigned.

IP61

Solids/access: Dust-tight under the test; wire-access protection.

Water: Vertical dripping-water test.

IP62

Solids/access: Dust-tight under the test; wire-access protection.

Water: Dripping-water test with enclosure tilted up to 15°.

IP63

Solids/access: Dust-tight under the test; wire-access protection.

Water: Spray test up to 60° from vertical.

IP64

Solids/access: Dust-tight under the test; wire-access protection.

Water: Splash test from all directions.

IP65

Solids/access: Dust-tight under the test; wire-access protection.

Water: Water-jet test.

IP66

Solids/access: Dust-tight under the test; wire-access protection.

Water: Powerful-water-jet test.

IP67

Solids/access: Dust-tight under the test; wire-access protection.

Water: Temporary immersion test with specified depth and time.

IP68

Solids/access: Dust-tight under the test; wire-access protection.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IP69

Solids/access: Dust-tight under the test; wire-access protection.

Water: High-pressure, high-temperature water-jet test.

IP6X

Solids/access: Dust-tight under the test; wire-access protection.

Water: Water digit omitted. No water classification supplied.

X
IPX0

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: No water protection assigned.

IPX1

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Vertical dripping-water test.

IPX2

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Dripping-water test with enclosure tilted up to 15°.

IPX3

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Spray test up to 60° from vertical.

IPX4

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Splash test from all directions.

IPX5

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Water-jet test.

IPX6

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Powerful-water-jet test.

IPX7

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Temporary immersion test with specified depth and time.

IPX8

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Continuous immersion under agreed conditions, more severe than digit 7; obtain the product’s limits.

IPX9

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: High-pressure, high-temperature water-jet test.

IPXX

Solids/access: Solids/access digit omitted. No digit-based claim supplied.

Water: Water digit omitted. No water classification supplied.

No digit-based protection information.

Optional Letters and What They Add

Additional letters concern access to hazardous parts, not extra dust or water resistance. They are used when access protection exceeds the first digit’s indication, or when that digit is X and only access protection is declared.

Additional LetterAccess Meaning
ABack-of-hand access protection.
BFinger-access protection.
CTool-access protection.
DWire-access protection.

For example, IP20C keeps the solids/water meaning of IP20 but adds tool-access protection. IPXXB supplies finger-access information through B while leaving both digits unspecified. These are decoding examples, not ratings assigned to the fixtures on this site.

Supplementary LetterMeaning
HHigh-voltage apparatus.
MWater testing performed with movable equipment parts in motion.
SWater testing performed with movable equipment parts stationary.
WSpecified weather conditions addressed with additional protective features or processes; consult the applicable requirements.

M and S describe test state, not a promise that the whole fixture may be moved through water. W does not mean universally weatherproof. These letters follow the digits and any additional access letter. Source: IEC 60529 clauses 7–9, checked in the publicly available 2013 standard text; the IEC Webstore remains the official edition reference.

Jets, Immersion and Hot Jets Are Separate

Do not read the second digit as one universal “better than” ladder. The water tests through 6 form one sequence. Immersion classes 7 and 8 are separate from jet classes 5 and 6. Digit 9 alone does not establish compliance with 5, 6, 7 or 8. Confirm each required category in the actual marking and documentation, such as IP66/IP68 or IP66/IP68/IP69, rather than inferring it.

An IP68 claim needs its agreed immersion conditions: depth/pressure, time and the stated operating configuration. A static immersion test does not reproduce moving water or cleaning jets. IEC tests use fresh water; solvents, saltwater, detergents and other conditions need their own support. IEC 60529 clause 6 and amendment 2 define these limits.

IP69 belongs to IEC 60529. Codes with K, including IP69K and IP6K9K, belong to different vehicle-related test conventions such as ISO 20653. Do not silently replace one marking with the other. Check the named standard and exact test declaration. EAO explains the distinction and multiple markings.

Practical Checks for Gaffers

SituationWhat to Check Before the Setup
Indoor dusty setDust protection and ventilation are different requirements. Verify the exact head rating, dust conditions and cleaning instructions; do not cover cooling openings to improvise protection.
Exterior rain or effects sprayCheck spray direction, exposure, mounting position and the manufacturer’s permitted operation. An IP23 head does not approve unrestricted wind-driven rain, jets or its ballast.
Wet floor and distributionCheck the power supply, connectors, joints and distribution independently. A head’s higher IP number does not upgrade a lower-rated or open connection.
Underwater shotUse equipment and a complete system specifically approved for the planned immersion and operation. IP67 alone is not an underwater-lighting or electrical-safety plan.
Washdown after a shootDo not hose a fixture merely because it carries an immersion code. Verify cleaning method, temperature, pressure, chemicals and any required isolation.
Rental prepRead the exact model’s manual and nameplate. Inspect seals, latches, port caps and properly mated approved connectors; confirm component ratings and replacement parts.

These are planning prompts, not a substitute for the manufacturer’s operating instructions or qualified electrical assessment. Preserve hot-lamp clearances, protective earth, circuit protection and any required isolation procedures independently of IP.

The defining authority is IEC 60529, Degrees of Protection Provided by Enclosures (IP Code). The official consolidated edition combines the 1989 standard and its 1999 and 2013 amendments, with listed corrigenda. This practical summary does not replace the standard’s test procedures or a fixture manual.

Authority and Supporting Sources

IEC 60529 official Webstore record is the authoritative standard reference. IEC’s public IP-ratings explainer is an introductory resource, not the full standard. The mappings above are paraphrased with supporting references from UL and the cited manufacturers; no standard table is reproduced.