FilmGear 24/20 kW Studio Tungsten Fresnel

Last Updated 21 hours ago

Overview

FilmGear 24/20 kW Studio Tungsten Fresnel
Rear housing and focus control on the FilmGear L24020TF
Rear housing and focus controlRear housing, focus knob and coiled head cable on the L24020TF. Photo: Digital Dynamics.
Model plate and connector on the FilmGear L24020TF
Model plate and connectorClose-up of the fixture’s model identification and the external unit’s output connector. Photo: Digital Dynamics.

The L24020TF uses a 625 mm Fresnel and 29-inch scrims. It accepts 20 kW or 24 kW lamps. FilmGear’s 24 kW table gives 20,784 lx in spot and 3,564 lx in flood at 15 m.

This is the 63 kg standard head, not the 56 kg lightweight version. The output table is for the 24 kW lamp; do not use it to estimate 20 kW output.

Detail photo

  • Studio Tungsten Fresnel 625 mm lens; standard-weight L24020TF head.
  • 20 or 24 kW 200–240 V AC with the correct single-ended lamp.
  • Colour Temperature3,200 K nominal.
  • Weight 63 kg lamphead; 69.5 kg with barndoors.
  • Beam Angle 13° spot / 56° flood in the 24 kW chart.
  • IP RatingIP23 FilmGear’s published fixture rating. Read the IP Rating.

Jump to Output Calculator ↓

Specifications

  • Model: L24020TF
  • Rated supply: 200–240 V AC
  • Fresnel lens: 625 mm. Scrim diameter: 736 mm
  • Lamp socket: G38
  • Mount: 28 mm (1⅛-inch) junior spigot
  • Lamphead weight: 63 kg

Photometrics are not safety clearances. FilmGear specifies at least 12 m (39.4 ft) to an illuminated object and 2.5 m (8.2 ft) to flammable objects. The calculator uses only the 24 kW data at 15–20 m. FilmGear L24020TF datasheet.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The 625 mm Fresnel gives a long-throw hard source at spot and much broader coverage at flood. The 63 kg head and manufacturer’s 12 m minimum to illuminated objects make it a studio-scale option, not a close key.

Practical Uses

Plan it as a distant hard key through a large opening, or compare flood against the width of a stage backing before booking. Check coverage at the actual throw; lux at beam centre is not the reading at the edges or after diffusion.

Output and Colour

FilmGear gives centre illuminance in lux and beam diameter in metres. Its chart identifies the head, lamp wattage and focus position. The test voltage and lamp part number are unspecified.

The 10 m readings are factory reference values. FilmGear specifies a minimum distance of 12 m to the illuminated object for this head.

Working-distance limit: The 10 m rows below reproduce historical factory reference values, not a permitted working distance. FilmGear specifies a 12 m minimum distance to the illuminated object. The calculator is restricted to its published 15–20 m measurements and interpolation between them.

24,000 W · Spot (13°)
ThrowIlluminanceBeam diameter
10 m46,763 lx2.28 m
15 m20,784 lx3.42 m
20 m11,691 lx4.56 m
24,000 W · Flood (56°)
ThrowIlluminanceBeam diameter
10 m8,019 lx10.63 m
15 m3,564 lx15.95 m
20 m2,005 lx21.27 m

The table is for the 24,000 W Studio Fresnel only. FilmGear does not give a 20,000 W curve here, so the 20 kW setting cannot be calculated by multiplying the 24 kW values by a wattage ratio.

Power and Batteries

Ushio’s BCM/208V, part 1002288, is a 20,000 W, 208 V G38 lamp rated 3,200 K and 400 hours. It is distinct from the 24 kW configuration plotted by FilmGear.

The L24020TF is a Class I, 200–240 V AC fixture. The supported 20 kW and 24 kW lamp classes do not establish approval for every G38 lamp; match the exact lamp voltage, fixture nameplate and rental-house instructions.

Control, Cooling and Camera Operation

The spec lists the L24020TF at ±30° operating tilt, 45°C maximum ambient and 240°C maximum surface temperature. Apply the most restrictive applicable limit for the fitted lamp and head. The standard inlet has no switch in the datasheet; FilmGear lists a rotary or panel switch on request and a fixture-specific electronic dimmer as an option.

Modifiers, Rigging and the Working Package

FilmGear lists a rotating four-leaf barndoor with a safety wire and 736 mm scrims. The specified weight rises from 63 kg head-only to 69.5 kg with doors; have qualified crew verify the complete support and secondary retention for the actual rig.

Alternatives and Related Fixtures

The L24020TF Studio Fresnel is not FilmGear’s L2420TF-LW lightweight Fresnel, the L24020TPB Power Beam or an older Cinemills head. Do not apply their lens, clearances, weight or beam charts to this model.

What People Are Saying

Practical takeaways from FilmGear’s L24020TF specifications, not independent owner reviews.

What worked

  • At 15 m, the 24 kW spot gives a documented 20,784 lux at beam centre, for a defined long-throw key or accent.
  • At the same distance the 56° flood covers 15.95 m across, useful for broad backings when the lower centre reading is acceptable.
  • Rotating barndoors and full or half scrims provide aim-specific spill and level control without treating electronic dimming as colour-neutral.

Drawbacks to plan for

  • Do not use the 10 m chart reading as an operating distance. FilmGear sets 12 m to illuminated objects and 2.5 m to flammables.
  • FilmGear lists 69.5 kg with doors and only ±30° tilt. Both matter when scoping a steep or suspended shot.
  • The nominal 20 kW rating does not come with a 20 kW photometric table. Verify lamp approval and meter the chosen package rather than using the 24 kW curve.

Videos

Illustrated fixture reference: FilmGear’s L24020TF drawing and accessory sheet shows the dimensions, barndoor package and head-specific operating limits. Match the identity number before using the drawing to plan clearance or transport.

Rental and Used-Fixture Checks

Before You Book

Confirm the installed wattage, voltage and rigging load with the rental house. Respect the 12 m minimum to the illuminated object; the 10 m factory row is not a permissible working distance.

Documentation and Specifications

Tungsten Fresnel directory · Tungsten and PAR lamp code lookup