Lowel Rifa eX 66 softlight
Lowel LC-96Z Rifa eX 66 kit with hard case
Rifa eX 66 kitThe 66 shown in Lowel’s LC-96Z hard-case kit. Used packages may not include every accessory. Photo: B&H.
Ushio EHF 750 W 120 V tungsten-halogen lamp
EHF tungsten lampThe 750 W, 120 V tungsten lamp in Lowel’s published 66 output table. Photo: B&H.

The Lowel Rifa eX 66 (LC-66EX) opens to a 25 × 25 in / 63.5 × 63.5 cm diffusion front. It ships with a TH-X1000 lamphead, but the 66 itself is limited to 750 W.

That 750 W limit still applies even though the larger 88 uses the same lamphead. Lock the frame open and fit the correct diffuser before use. Select a lamp for the actual supply voltage.

Detail photo

  • Fixture Type Collapsible tungsten softlight · LC-66EX
  • Power 750 W maximum; supplied TH-X1000.
  • Colour Temperature3,200 K EHF/FKR or 3,000 K EHG in the factory lamp table.
  • Weight 3.5 lb / 1.6 kg with captive cable.
  • Beam Angle 75° nominal with the bare diffuser in Lowel’s beam diagram. 25 × 25 in front; optional 30°, 40° and 50° grids shape spill.
  • IP Rating No numerical IP rating stated in the checked material. Read the IP Rating.

Jump to Output Calculator ↓

Specifications

  • Manufacturer code: LC-66EX
  • Collapsed length: 30 in / 76 cm
  • Supplied lamphead: TH-X1000
  • Front diffuser: 25 × 25 in / 63.5 × 63.5 cm
  • Maximum lamp power: 750 W
  • Maximum current: 6.25 A at 120 V
  • Weight with captive cable: 3.5 lb / 1.6 kg
  • Standard tungsten lamphead with eXchange accessory-lamphead system
Source check: Lamp codes, voltage, colour temperature, life and the paired 5 ft / 10 ft readings below come from Lowel’s Rifa eXchange instruction sheet. The calculator uses the Lamp/Beam Data table for this model’s standard lamphead, without substituting another Rifa size’s readings.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The lamp and folding softbox are one package, so there is no separate speed ring to build. The trade-offs are tungsten heat, mains power and a fixed front size. Allow for cooling between moves and meter the actual diffuser or grid.

Practical Uses

The 25-inch Rifa eX 66 makes a useful interview key or close fill where tungsten balance is wanted. Move the box close for a soft key and use the optional soft egg crate when the background needs to stay darker. Lowel’s measured grid curves show an output loss, so compare the bare factory reading with a meter reading through what you actually mount. See Lowel’s grid diagrams.

Lamps and voltage

LampVoltagePowerCCTAverage life5 ft / 1.524 m10 ft / 3.048 m
EHF120 V750 W3200 K300 h109 fc / 1180 lux30 fc / 326 lux
EHG120 V750 W3000 K2,000 h89 fc / 962 lux24 fc / 262 lux
FKR/240240 V650 W3200 K300 h92 fc / 990 lux25 fc / 270 lux

Output and photometrics

The manufacturer sheet’s Lamp/Beam Data table and beam-angle diagrams contain slightly different centre readings for some matching lamps. The saved measurements consistently use the Lamp/Beam Data table; the two presentations are not combined. This extended soft source is limited to the published 5–10 ft (1.524–3.048 m) measurement range. Values between those distances are estimates, not additional manufacturer tests; no values are extrapolated outside that range.

These are centre readings through the normal Rifa diffuser with the specified standard lamphead and globe. Lamp choice changes output and operating colour; the larger Rifa sizes may accept some lower-wattage lamps, but those combinations are not assigned another model’s readings.

Lampheads and Light Control

The supplied TH-X1000 is shared by the Rifa eX 55, 66 and 88. The TH-X300 can be fitted as an accessory for lower-power or low-voltage lamps; the measurements above apply only to the supplied head and listed lamp.

Optional fabric egg crates are offered in 30°, 40° and 50° versions. They reduce spill and output; the ungridded measurements above do not describe output with an egg crate installed.

Use and safety

Mount the light on a stand with one leg under the forward load, lock the frame open, fit the diffuser, and then connect the switched extension. Do not pull the power cable to unfold the fixture. Unplug and cool it before changing lamps or lampheads, and never exceed the model’s maximum wattage.

Match the lamp voltage and approved power cable to the supply. A low-voltage lamp must not be connected to a higher-voltage source. Use only one supplied Lowel diffuser, and let the light cool for at least five minutes before packing it. Roll the diffuser around its storage tube rather than folding it.

Control and Camera Operation

Choose the colour temperature by lamp, not by an electronic CCT control. If external tungsten dimming is used on a compatible supply, check the warmer colour at lower dim levels against the camera white balance. Change distance, or use the fixture’s compatible soft egg crate where spill needs to be reduced. Meter the altered setup to check both exposure and coverage. The optional fluorescent lamphead is a separate setup and should not be treated as a dimmable tungsten head.

Compare softbox sizes and lamp options: Rifa eX 88.

The Rifa eX 55 is smaller and rated to 500 W; the Rifa eX 88 uses a 32-inch front and accepts 1,000 W.

What People Are Saying

Reports on the older Rifa 66 are identified as such. They describe real working choices, but do not verify interchangeable-lamphead support or output for every eX66.

What people liked

  • Compact for one-person interview travel. In Jaron Berman’s DV Info report, a Rifa 66 travelled in a stand bag as part of a solo interview kit. Berman removed the lamp for transport. He did not specify the eX revision.
  • Worked as a regular tungsten video light. Photographer Ron Martinsen identifies the eX66 Pro kit in his disclosed studio-lighting article, says he used the Rifa for video and preferred tungsten for that work. It is a firsthand use note rather than a measured comparison.
  • A crate is useful when you need directional soft fill. In the Creative COW Rifa 66 discussion, owner Mark Price reports using his 44, 55 and 66 with 40° grids for easier spill control. He does not isolate which eX revision he owned.

What to watch for

  • A grid will not turn it into a hard cut. In the same discussion, Charles Mercer still had background spill in tight offices with a gridded Rifa 66. Allow room for an external flag or choose a focused source when the background needs to stay dark.
  • An accessory head changes balance. Price reported that a three-lamp fluorescent head sometimes made the yoke sag with his Rifa kit. That is not a claim that a standard tungsten eX66 droops. Check the tilt lock and support with the complete working package.
  • Match the voltage and leave strike time. Lowel’s eXchange instructions tables a 120 V/750 W EHF and a different 240 V/650 W FKR/240 for the eX66; do not interchange them across supplies. Keep the approved diffuser installed in use and allow at least five minutes after unplugging before disassembly.

Videos

Brooklyn Free Speech’s equipment team demonstrates the folding, setup and handling of a Rifa eX 55. It shows the family’s umbrella-style design, not the eX 66 lamp options or output. Use the eX 66 lamp table above and Lowel’s instructions for this fixture.

Rental and Used-Fixture Checks

Before You Book

  • Match head, lamp and supply. Check the exact eX 66 fixture and tungsten lamphead. Verify lamp voltage and code against the factory table; a physical fit does not make a different voltage acceptable.
  • Inspect what holds the box open. Check the lock, frame ends, tilt lock, diffuser, fabric and cable before powering the fixture. If using a soft egg crate, meter through it.
  • Pack for the lamp you’re using. Let the head cool before handling it. If you have the optional fluorescent head, Lowel requires that head and lamps to be removed before collapsing the box. Check the instructions and leave time before wrap.

Documentation

Browse Lowel lights · browse tungsten lights · all equipment