Last Updated 22 hours ago
Altman 1200SE Overview



The Altman Proline 1200SE is a 1,200 W single-ended daylight Fresnel for film and video work. Its front and rear focus controls adjust the lamp-and-reflector carriage from spot to flood. Altman supplied the 1200SE-M with a magnetic ballast and the 1200SE-E with an electronic ballast; 1200SE-H identifies the head alone.
The G38 lamp and the ballast shown here are separate references: the lamp photo illustrates the specified single-ended format, while the kit photo shows the 1200SE-E package, not the magnetic-ballast version.
- TypeDaylight Fresnel; 175 mm lens, pulse-rated G38 and 9 in accessories
- Power1,200 W SE lamp; 1200SE-M magnetic / -E electronic / -H head only
- Colour Temperature5,600 K nominal per factory 1,200 W lamp table
- Weight21 lb head; add 14 lb electronic or 47 lb magnetic ballast
- Beam AngleSpot/flood; labels 18°/68° and diameter chart don’t agree as same boundary
- IP RatingNo model-specific numeric IP rating verified in the applicable source; do not infer weather protection. IP rating guide.
1200SE Specifications
| Specification | Factory Record |
|---|---|
| Models | 1200SE-H head; 1200SE-M magnetic package; 1200SE-E electronic package |
| Lamp | 1,200 W single-ended metal-halide; factory lamp table: 5,600 K, nominal 100 V, 110,000 lm, 750-hour rated life, any burning position. The Carbone source separately pictures an OSRAM HMI 1200 W/SEL lamp. |
| Socket | Pulse-rated G38 mogul bipost |
| Lens | 6.8 in (175 mm) borosilicate Fresnel; marketed as 7 in |
| Housing and Focusing | Die-cast/extruded aluminum; spherical aluminum reflector; worm-gear carriage on Teflon guides with front and rear controls |
| Head Circuit Rating | 100 V AC, single phase, 13.8 A, 1,200 W maximum. These are lamphead values, not mains-input ratings. |
| Head Weight | Approximately 21 lb (9.5 kg), head only |
| Package Weight Additions | Approximately 14 lb (6.5 kg) for electronic ballast or 47 lb (21.3 kg) for magnetic ballast |
| Accessory Size | 9 in (22.9 cm) |
| Head Lead and Interconnect | 24 in head lead; detachable 25 ft interconnect included with both packages; VEAM ballast-to-head connection |
| Factory Drawing | 11⅝ in side-view length; 14⅞ in body height and 22¼ in height with yoke in the illustrated position. Consult the drawing for clearance and orientation. |
| Safety | Access-door switch interrupts power; front wire screen, safety cable and hinged filter frame supplied |
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
Choose it when you need a daylight Fresnel that can narrow onto a subject or open up for a broader wash, with the focus knob accessible from either end. It is a less convenient choice when ballast weight, long cable runs or actual power draw are the deciding factors. The magnetic and electronic packages are not the same load.
Practical Uses
| Use | Working Approach |
|---|---|
| Daylight Booster | Add a controllable daylight source where available light needs reinforcement. |
| Key or Fill Light | Focus the Fresnel and shape the field with the matching barndoor and scrims. |
| Used-Package Matching | Confirm head, lamp, ballast suffix and connector before substituting components. |
Output and Colour
The calculator uses the factory spot and flood centre readings from 10–40 ft. The drawing does not establish that its printed angles and diameters use the same beam boundary. It does not identify a ballast for this test. Use the separate diameter table as printed; the calculator does not predict coverage.
Altman labels this chart “calibrated CCD camera measurements” with a 1,200 W single-ended lamp. It gives 700,000 cd at spot and 52,000 cd at flood. The chart does not identify the test ballast, lamp manufacturer or operating hours.
| Distance (ft) | Spot (fc) | Flood (fc) |
|---|---|---|
| 10 | 7,000 | 520 |
| 15 | 3,111 | 231 |
| 20 | 1,750 | 130 |
| 25 | 1,120 | 83 |
| 30 | 778 | 58 |
| 40 | 438 | 33 |
| Factory Chart Label | Spot | Flood |
|---|---|---|
| Field Angle | 18° | 68° |
| Printed Diameter at 10 ft | 1.2 ft | 10.4 ft |
The published field angles and diameter figures do not describe matching geometric cones if read at the same boundary. Use the illuminance table for output comparison, not these conflicting geometry labels to predict coverage. No beam-diameter estimate is derived here.
Power and Batteries
A separate ballast is required; Altman’s sheet does not list direct battery power for the head. Match its individual voltage/frequency version and head connector; the head’s 100 V lamp-circuit rating is not the wall-supply voltage.
| Ballast | Factory Input and Controls |
|---|---|
| 1200MB Magnetic | 120 V / 60 Hz: 14 A maximum; 220 V / 50 Hz or 240 V / 50 Hz: 7 A maximum. Recessed bipolar main breaker; ON, OFF and REMOTE controls. |
| 575/1200EB Electronic | 120 V: 17.6 A maximum; 220 V: 9 A maximum. Input breaker, separate ignite/stop controls, square-wave/silent selector and dimming to 50%. |
| Both Documented Packages | VEAM head connection; 6 ft 14/3 SJT input cord, with three-prong Edison on the standard 120 V / 60 Hz version. Stainless-steel ballast housing. |
These are specifications for the versions in Altman’s 2003 sheet, not a continuous universal-input range. The magnetic specification differs from the historical Lexicon’s 13.5 A/fuse entry: this factory sheet states 14 A and a breaker. It does not establish a 208 V / 60 Hz variant.
Control, Cooling and Camera Operation
Set beam size with the front or rear mechanical focus control. The head has on/off control and an access-door interlock; the electronic ballast provides the documented Square Wave/Silent selection and dimming. The 1200MB magnetic ballast has a separate Remote position; it is not the electronic ballast’s camera-mode selector.
Check flicker at the exact camera frame rate and shutter after the lamp stabilises, and listen for lamp and ballast noise from the mic position. Do not assume Silent is the right setting for high-speed filming. Keep ventilation unobstructed and leave the head and the front accessories to cool before handling.
Modifiers, Rigging and the Working Package
The tubular steel yoke has a ½ in opening and locking handle. The supplied F-SAL combination spigot is ⅝ in × 1⅛ in. Allow for accessories and cable load beyond the 21 lb head weight; check the door interlock, front mesh, lens, yoke and connectors before use.
| Part | Factory Description | Package Status |
|---|---|---|
| SC-36-BK | Safety cable with spring clip | Supplied |
| 72-0046 | F7 front mesh | Supplied |
| F7-BD4 | Four-leaf barndoor | Supplied |
| 54-5007 | 25 ft interconnect cable | Supplied |
| F7-FF | Hinged filter frame | Supplied |
| F-SAL | Combination ⅝ in × 1⅛ in spigot | Supplied |
| F-CRL | Long cord wrap | Supplied |
| F7-BD8 | Eight-leaf barndoor | Additional |
| F7-SN | Three-in-one snoot set | Additional |
| F7-FS / F7-HS | Full single / half single scrims | Additional |
| F7-FD / F7-HD | Full double / half double scrims | Additional |
| 510 | Malleable-iron pipe clamp | Additional |
| 54-5008 | 50 ft HMI interconnect cable | Additional |
Alternatives and Related Fixtures
- ARRI True Blue D12: another focusable 1.2 kW daylight Fresnel; rent its matched head, ballast and cable rather than assuming interchangeability.
- ARRI M18: lensless MAX reflector when you need more throw or a 1.8 kW option instead of the Fresnel lens.
What People Are Saying
Field Feedback at a Glance
These points come from Altman’s 1200SE factory sheet, not independent tests or owner reviews.
What works
- The worm-gear carriage can be adjusted from the front or back. You can set the beam from whichever side stays accessible after rigging.
- The published spot reading is 7,000 fc at 10 ft versus 520 fc at full flood; that is a substantial centre-light change without swapping lenses.
- Altman’s kit included the four-leaf barndoor, hinged filter frame and safety cable; the separate F7 scrims give more control without changing ballast mode.
Drawbacks to plan for
- The magnetic ballast adds about 47 lb to a 21 lb head before cable and accessories. The electronic ballast is roughly 14 lb, so confirm which package you are moving.
- Altman lists a maximum of 17.6 A at 120 V for the electronic ballast; the head’s 13.8 A lamp-circuit rating is not a supply-current estimate.
- The factory chart does not identify its test ballast or lamp age and its angles do not line up with the printed beam diameters. Use the calculator for centre exposure, and check actual coverage on set.
Videos and Operating Reference
Use the factory rear/side drawing and controls table to identify head and ballast connections, and confirm the applicable input, selector and accessories against the package in front of you.
Rental and Used-Fixture Checks
Before You Book
Photograph both nameplates and every connector. Record the lamp code, ballast model, head cable and accessory size. Test cold start, stable running, hot restrike, focus travel and camera behaviour before accepting the package.
Documentation and Specifications
Altman 1200SE Original Factory Sheet (2003) · Altman Product Support · OSRAM HMI family guide.
Browse Altman Lighting · HMI lights · all equipment.