FilmGear Daylight PAR 200W Overview



The FilmGear Daylight Par 200W (L00200DP) is a nominal 5,600 K discharge PAR with 130 mm optics. It is the full-size 200 W PAR head, not the L00200DM Mini with its smaller optics and lighter housing.
It uses a GZY9.5 HMI 200 W SE lamp, a matched head cable and a compatible electronic ballast. The 70 V figure applies to the lamp circuit; use the ballast nameplate to plan mains power. FilmGear lists a 2 m minimum to illuminated objects.
- Daylight HMI PAR Interchangeable-lens daylight PAR; Ø130 mm protective and PAR lens; Ø16 mm / 5/8 in socket.
- 200 W lamp + external ballast GZY9.5. Use the matched ballast. 70 V belongs to lamp circuit, not mains.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 3.2 kg lamphead; 3.7 kg with barndoor.
- Beam Angle Spot 9°; Medium flood 10° × 20°; Wide flood 20° × 40°; Super wide flood 40°; Frosted super flood 32°.
- IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.
FilmGear Daylight PAR 200W Specifications
| Specification | Details |
|---|---|
| Identity number | L00200DP |
| Capacity | 200 W |
| Lamp circuit | 70 V |
| Optic | Ø130 mm protective and PAR lens |
| Lamp | HMI 200W SE |
| Colour temperature | 5600 K |
| Lamp holder | GZY9.5 |
| Stirrup | Ø16 mm / 5/8 in socket |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 190 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 2 m |
| Minimum distance to flammable object | 0.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 3.2 kg |
| Weight with barndoor | 3.7 kg |
The voltage listed for the lamp is its lamp-circuit rating, not the ballast’s mains input. Check the supplied ballast and its nameplate for power planning.
Output Calculator
The calculator uses FilmGear’s 2–6 m readings and estimates between those distances only. It cannot predict a reading closer than the 2 m minimum illuminated-object distance.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
Strengths
- The 9° spot reads 68,175 lux at FilmGear’s 2 m test distance.
- The 10° × 20° medium and 20° × 40° wide inserts allow different footprint shapes from the same head.
- At 3.2 kg bare, the standard head remains relatively compact despite taking the larger 130 mm optics.
Limitations
- The 2 m illuminated-object clearance is still required even though this is a 200 W head.
- The 40° super-wide optic reads 6,363 lux at 2 m against 68,175 lux for the 9° spot.
- The 112 mm lenses for the 200W Mini do not fit the full-size head’s 130 mm optic slot.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Start with the narrowest documented beam setup for a distant subject. Check beam width and meter the light at the subject before setting exposure. |
| Beam shaping | Use the lens set to trade centre intensity for wider coverage. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
The standard 200W takes 130 mm PAR lenses. Before final aim, rotate the asymmetric flood lens so the wider axis falls where it is useful.
Output and Colour
FilmGear measured the centre of the beam for each configuration below.
| Configuration | 2 m | 4 m | 6 m |
|---|---|---|---|
| Spot 9° | 68,175 lux | 17,044 lux | 7,575 lux |
| Medium flood 10° × 20° | 29,315 lux | 7,329 lux | 3,257 lux |
| Wide flood 20° × 40° | 11,953 lux | 2,988 lux | 1,328 lux |
| Super wide flood 40° | 6,363 lux | 1,591 lux | 707 lux |
| Frosted super flood 32° | 5,090 lux | 1,273 lux | 566 lux |
Use these centre-beam readings only with the stated lamp, optic and test configuration. They do not describe an average across the beam.
Power and Batteries
FilmGear lists 400W/200W, 400W/200W AC/DC, 200W or 200W AC/DC electronic ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Verify which 130 mm insert is fitted before setting the shot. The oval medium and wide floods can be oriented to the shape of the subject. The 130 mm protective front and the interchangeable lens have separate roles; do not run with the protective glass missing. Check ballast mode and warm-up with the intended shutter and frame rate. FilmGear specifies a maximum surface temperature of 190 °C and 45 °C maximum ambient; leave cooling paths open and allow the head to cool before handling.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the smaller 200 W Mini PAR for a lighter head or the 200 W SE Fresnel for continuous focus with no spread-lens swaps. Neither chart applies to L00200DP.
What People Are Saying
These checks come from FilmGear’s exact standard PAR sheet. They describe documented trade-offs, not independent operator reviews.
- Five coverage choices FilmGear supplies spot, medium, wide, super-wide and frosted lenses for the 130 mm set. At 4 m, the published medium footprint is 0.70 × 1.41 m.
- Fits a baby pin The head uses a 16 mm socket, not the 28 mm spigot of the larger PAR fixtures. It is 3.7 kg with barndoor.
- Choice of AC or supported AC/DC packages The same head can be paired with approved 200 W and 400/200 W ballasts. Check the ballast and connectors supplied, rather than assuming every head kit has DC capability.
- Do not use Mini lens data or accessories FilmGear’s L00200DM Mini takes 112 mm optics. L00200DP is the full-size 130 mm head despite the same nominal lamp rating.
- The battery hookup is not on the head 70 V is the lamp rating. An AC/DC ballast requires its own compatible power arrangement; a dual 400/200 W control does not authorize a 400 W lamp in this head.
- Clearance still applies to a small HMI FilmGear specifies 2 m to the illuminated object and 0.5 m to flammables. Do not treat a calculated reading as approval to work closer.
Videos and Operating Reference
Read the full-size FilmGear 200 W PAR operating reference. Check the 130 mm optics, the head and ballast options, front view and published clearances. It is not the 200 W Mini sheet.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Confirm head model L00200DP. Match it with HMI 200W SE, GZY9.5, actual ballast model/input and keyed head cable. Check 16 mm / 5/8 in socket, 130 mm protective and PAR lens, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 2 m illuminated-object clearance and unit-specific manufacturer instructions.
Documentation and Specifications
The lamphead photo is FilmGear’s product image reproduced in the Carbone lighting reference. The separate ballast is pictured by Film Gear USA.
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.