Last Updated 21 hours ago
FilmGear Daylight PAR 1.8k/1.2k Overview



The FilmGear Daylight Par 1.8k/1.2k (L01812DP) takes either a 1,800 W or 1,200 W single-ended discharge lamp. It uses interchangeable 250 mm PAR lenses behind a 265 mm protective lens.
The two lamp ratings belong to the lamp circuit, not the mains supply. Match the lamp, wattage setting, ballast and head cable as a package. Keep the two sets of photometric readings separate when planning a shot.
- Daylight HMI PAR Ø265 mm protective lens; Ø250 mm PAR lens; Ø28 mm / 1-1/8 in spigot.
- 1,800 W / 1,200 W lamp + external ballast G38. 140 V / 100 V belongs to the lamp circuit, not mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 12.7 kg lamphead; 14.4 kg with barndoor.
- Beam Angle Interchangeable lenses. 1,800 W · spot 8.5°; 1,200 W · spot 8°. Compare individual lens settings below.
- IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.
FilmGear Daylight PAR 1.8k/1.2k Specifications
| Specification | Details |
|---|---|
| Identity number | L01812DP |
| Capacity | 1,800 W / 1,200 W |
| Lamp circuit | 140 V / 100 V |
| Optic | Ø265 mm protective lens; Ø250 mm PAR lens |
| Lamp | HMI 1800W/SE or HMI 1200W/SE |
| Colour temperature | 5600 K |
| Lamp holder | G38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 160 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 6 m |
| Minimum distance to flammable object | 1 m |
| Operating range | +45° to -45° |
| Lamphead weight | 12.7 kg |
| Weight with barndoor | 14.4 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 6 to 12 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 6 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
L01812DP packs two specified lamp ratings and five optical choices into one head. It is useful for hard daylight through windows or when beam shape matters more than fast beam changes. Unlike the F1.8k, changing the optical spread can mean changing a lens. Allow for a 14.4 kg head with barndoor, plus the ballast, cable and lens case.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the lens set to trade centre intensity for wider coverage. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 6 m | 9 m | 12 m |
|---|---|---|---|
| 1,800 W · spot 8.5° | 53,400 lux | 23,730 lux | 13,350 lux |
| 1,800 W · medium 9° × 18° | 36,000 lux | 16,000 lux | 9,000 lux |
| 1,800 W · wide 18° × 42° | 10,000 lux | 4,440 lux | 2,500 lux |
| 1,800 W · super wide 38° | 4,200 lux | 1,870 lux | 1,050 lux |
| 1,800 W · frosted 37° | 2,500 lux | 1,110 lux | 630 lux |
| 1,200 W · spot 8° | 46,151 lux | 20,512 lux | 11,538 lux |
| 1,200 W · medium 10° × 20° | 17,885 lux | 7,949 lux | 4,471 lux |
| 1,200 W · wide 20° × 45° | 5,513 lux | 2,450 lux | 1,378 lux |
| 1,200 W · super wide 40° | 3,066 lux | 1,363 lux | 767 lux |
| 1,200 W · frosted 38° | 2,281 lux | 1,018 lux | 570 lux |
Use the table and calculator only with the stated lamp, optic and test configuration.
Power and Batteries
FilmGear lists 1.8kW/1.2kW/575W V3 electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Confirm the lamp wattage and install the lens named in the selected chart row. For an asymmetric lens, check which way the beam spreads on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use. Do not handle or swap hot glass; allow the head to cool and keep cooling paths clear. FilmGear lists a maximum surface temperature of 160 °C and maximum ambient temperature of 45 °C.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare FilmGear’s F1.8k Faceted PAR for lensless spot-to-flood adjustment, or the L01812DS Fresnel for its smooth manual focus. Neither uses this L01812DP’s photometric chart.
What People Are Saying
FilmGear’s exact factory sheet support the working notes below. They are documented trade-offs, not independent crew reviews.
- Five real lens choices The included 250 mm lenses cover spot, medium, wide, super wide and frosted super flood. Their spread is not the same as the single focusable optic in the F1.8k.
- A choice of two specified lamp builds The same head is specified for G38 single-ended HMI at 1,800 W/140 V or 1,200 W/100 V. FilmGear publishes both sets of readings at 6, 9 and 12 m.
- Oval coverage can serve a long opening At 9 m the 1,800 W medium flood measures 1.42 × 2.85 m, compared with a 1.38 m round spot. Check its orientation on the subject.
- Wide coverage costs centre intensity At 9 m with the 1,800 W lamp, the spot is 23,730 lux; the frosted super flood is 1,110 lux. Match the row to the actual lens rather than assuming one output figure.
- Allow room and setup time FilmGear specifies a 6 m illuminated-object minimum and 1 m to flammables. Lens swaps add handling compared with a faceted PAR.
- The 575 W ballast selector is not a third lamp option The V3 ballast also supports a separate 575 W head. FilmGear lists only 1,800 W and 1,200 W G38 lamps for the L01812DP.
Videos and Operating Reference
Read the FilmGear L01812DP operating reference. It shows the two lamp/voltage classes, front assembly, five-lens set, dimensions and working limits.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.