FilmGear Daylight PAR 1.8k/1.2k Overview

FilmGear Daylight Par 1.8k/1.2k lamphead
FilmGear V3 1.8 kW/1.2 kW/575 W electronic ballast
Multi-wattage ballastThe FilmGear V3 ballast family supports 1.8 kW and 1.2 kW with the appropriate configuration. Photo: Film Gear USA.
OSRAM HMI 1200 W/SE G38 single-ended lamp
1.2 kW G38 lampOne of the two wattage classes shown. A 1.2 kW lamp is not a substitute for the 1.8 kW results. Photo: Simply Sound and Lighting.

The FilmGear Daylight Par 1.8k/1.2k (L01812DP) takes either a 1,800 W or 1,200 W single-ended discharge lamp. It uses interchangeable 250 mm PAR lenses behind a 265 mm protective lens.

The two lamp ratings belong to the lamp circuit, not the mains supply. Match the lamp, wattage setting, ballast and head cable as a package. Keep the two sets of photometric readings separate when planning a shot.

Detail photo

  • Daylight HMI PAR Ø265 mm protective lens; Ø250 mm PAR lens; Ø28 mm / 1-1/8 in spigot.
  • 1,800 W / 1,200 W lamp + external ballast G38. 140 V / 100 V belongs to the lamp circuit, not mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 12.7 kg lamphead; 14.4 kg with barndoor.
  • Beam Angle Interchangeable lenses. 1,800 W · spot 8.5°; 1,200 W · spot 8°. Compare individual lens settings below.
  • IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

FilmGear Daylight PAR 1.8k/1.2k Specifications

SpecificationDetails
Identity numberL01812DP
Capacity1,800 W / 1,200 W
Lamp circuit140 V / 100 V
OpticØ265 mm protective lens; Ø250 mm PAR lens
LampHMI 1800W/SE or HMI 1200W/SE
Colour temperature5600 K
Lamp holderG38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature160 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object6 m
Minimum distance to flammable object1 m
Operating range+45° to -45°
Lamphead weight12.7 kg
Weight with barndoor14.4 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

The calculator uses FilmGear readings from 6 to 12 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 6 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

L01812DP packs two specified lamp ratings and five optical choices into one head. It is useful for hard daylight through windows or when beam shape matters more than fast beam changes. Unlike the F1.8k, changing the optical spread can mean changing a lens. Allow for a 14.4 kg head with barndoor, plus the ballast, cable and lens case.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the lens set to trade centre intensity for wider coverage.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration6 m9 m12 m
1,800 W · spot 8.5°53,400 lux23,730 lux13,350 lux
1,800 W · medium 9° × 18°36,000 lux16,000 lux9,000 lux
1,800 W · wide 18° × 42°10,000 lux4,440 lux2,500 lux
1,800 W · super wide 38°4,200 lux1,870 lux1,050 lux
1,800 W · frosted 37°2,500 lux1,110 lux630 lux
1,200 W · spot 8°46,151 lux20,512 lux11,538 lux
1,200 W · medium 10° × 20°17,885 lux7,949 lux4,471 lux
1,200 W · wide 20° × 45°5,513 lux2,450 lux1,378 lux
1,200 W · super wide 40°3,066 lux1,363 lux767 lux
1,200 W · frosted 38°2,281 lux1,018 lux570 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Use the table and calculator only with the stated lamp, optic and test configuration.

Back to contents

Power and Batteries

FilmGear lists 1.8kW/1.2kW/575W V3 electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Confirm the lamp wattage and install the lens named in the selected chart row. For an asymmetric lens, check which way the beam spreads on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use. Do not handle or swap hot glass; allow the head to cool and keep cooling paths clear. FilmGear lists a maximum surface temperature of 160 °C and maximum ambient temperature of 45 °C.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Compare FilmGear’s F1.8k Faceted PAR for lensless spot-to-flood adjustment, or the L01812DS Fresnel for its smooth manual focus. Neither uses this L01812DP’s photometric chart.

What People Are Saying

FilmGear’s exact factory sheet support the working notes below. They are documented trade-offs, not independent crew reviews.

  • Five real lens choices The included 250 mm lenses cover spot, medium, wide, super wide and frosted super flood. Their spread is not the same as the single focusable optic in the F1.8k.
  • A choice of two specified lamp builds The same head is specified for G38 single-ended HMI at 1,800 W/140 V or 1,200 W/100 V. FilmGear publishes both sets of readings at 6, 9 and 12 m.
  • Oval coverage can serve a long opening At 9 m the 1,800 W medium flood measures 1.42 × 2.85 m, compared with a 1.38 m round spot. Check its orientation on the subject.
  • Wide coverage costs centre intensity At 9 m with the 1,800 W lamp, the spot is 23,730 lux; the frosted super flood is 1,110 lux. Match the row to the actual lens rather than assuming one output figure.
  • Allow room and setup time FilmGear specifies a 6 m illuminated-object minimum and 1 m to flammables. Lens swaps add handling compared with a faceted PAR.
  • The 575 W ballast selector is not a third lamp option The V3 ballast also supports a separate 575 W head. FilmGear lists only 1,800 W and 1,200 W G38 lamps for the L01812DP.

Videos and Operating Reference

Read the FilmGear L01812DP operating reference. It shows the two lamp/voltage classes, front assembly, five-lens set, dimensions and working limits.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.