FilmGear Daylight Fresnel 1.8k/1.2k

Last Updated 21 hours ago

Daylight Fresnel 1.8kW/1.2kW SE Overview

FilmGear Daylight Fresnel 1.8k/1.2k lamphead
FilmGear V3 ballast 1.8 kW, 1.2 kW and 575 W
V3 electronic ballastFilmGear’s ballast family with settings for the two lamp wattages. Check connector and cable. Photo: Film Gear USA.
OSRAM 1,200 W single-ended G38 HMI lamp
1.2 kW G38 lampExample of the 1,200 W single-ended lamp type. Use only its corresponding photometric series. Photo: Simply Sound and Lighting.

The FilmGear Daylight Fresnel 1.8k/1.2k (L01812DS) is a dual-wattage HMI Fresnel with a 175 mm lens. FilmGear publishes a 5° spot and 52° flood; the head weighs 9.7 kg bare.

Select either the 1,800 W or 1,200 W G38 lamp and match the ballast setting and head cable. The 140 V and 100 V figures apply to the lamp circuit. This is the Fresnel, not the interchangeable-lens 1.8k/1.2k PAR.

Detail photo

  • Daylight HMI Fresnel Ø175 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
  • 1,800 W / 1,200 W lamp + external ballast G38. 140 V / 100 V belongs to the lamp circuit, not mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 9.7 kg lamphead; 10.7 kg with barndoor.
  • Beam Angle Spot 5°; Flood 52°.
  • IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Daylight Fresnel 1.8kW/1.2kW SE Specifications

SpecificationDetails
Identity numberL01812DS
Capacity1,800 W / 1,200 W
Lamp circuit140 V / 100 V
OpticØ175 mm Fresnel
LampCSR 1800W/SE/HR or HMI 1800W/SE; MSR 1200HR or HMI 1200W/SE
Colour temperature5600 K
Lamp holderG38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature180 °C / 170 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object6 m
Minimum distance to flammable object0.5 m
Operating range+45° to -45°
Lamphead weight9.7 kg
Weight with barndoor10.7 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

The calculator uses FilmGear readings from 6 to 9 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 6 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The same Fresnel package is factory-specified for 1,800 W and 1,200 W single-ended lamps. Choose the mode for the actual beam, not wattage alone: FilmGear’s 1,800 W table is brighter in flood but lower at spot centre. The head requires the matched ballast and a long working distance.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration3 m6 m9 m
1,800 W · spot 5°90,000 lux20,000 lux9,000 lux
1,800 W · flood 52°12,000 lux3,200 lux1,500 lux
1,200 W · spot 5°102,403 lux25,601 lux11,378 lux
1,200 W · flood 52°7,799 lux1,950 lux867 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

The table keeps FilmGear’s published test readings. At 6 m the 1,200 W spot is brighter at centre (25,601 vs 20,000 lx), but the 1,800 W flood is brighter (3,200 vs 1,950 lx). FilmGear does not give a measured reason for that reversal. Distances below the stated minimum are reference measurements only and are not available in the calculator.

Back to contents

Power and Batteries

The 2025 L01812DS sheet specifies the V3 1.8kW/1.2kW/575W electronic ballast. A 1.2kW/575W ballast cannot operate a 1,800 W lamp; that smaller ballast is listed on the separate dedicated 1,200 W Fresnel sheet. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

The exact FilmGear sheet lists 229 mm full and half scrims, a rotating four-leaf door, a filter frame and 7 m or 15 m head leads. Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Compare the dedicated L01200DS if you only need 1,200 W operation. For a PAR beam, choose a dedicated daylight PAR with its own optical and accessory specifications.

What People Are Saying

Videos

Use the illustrated FilmGear L01812DS fixture sheet for the exact Fresnel, yoke, door, head cable and lamp options. It identifies this head without relying on footage of the PAR or another fixture from the family.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.