FilmGear Daylight Par 4k/2.5k

Last Updated 21 hours ago

Overview

FilmGear Daylight Par 4k/2.5k lamphead
FilmGear V3 4 kW/2.5 kW electronic ballast
4 kW/2.5 kW ballastCompatible ballast family for the PAR, with the head cable and lamp matched to the selected wattage. Photo: Film Gear USA.
OSRAM HMI 2,500 W/SE XS G38 single-ended lamp
2.5 kW G38 lampOne of the two wattage classes for this PAR. Check the exact lamp before use. Photo: Bank of Lamps.

The FilmGear Daylight Par 4k/2.5k (L04025DP) accepts a 4,000 W or 2,500 W single-ended discharge lamp. Its 300 mm interchangeable PAR lenses sit behind a 335 mm protective lens.

This is the interchangeable-lens PAR, not the 4k/2.5k Fresnel or the F4k faceted head. Match the lamps and output tables to each wattage, and use the ballast input rating when planning mains power.

Detail photo

  • Daylight HMI PAR Ø335 mm protective lens; Ø300 mm PAR lens; Ø28 mm / 1-1/8 in spigot.
  • 4,000 W / 2,500 W lamp + external ballast G38. 200 V / 115 V belongs to the lamp circuit, not mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 19.6 kg lamphead; 22.1 kg with barndoor.
  • Beam Angle Interchangeable lenses. 4,000 W · spot 8°; 2,500 W · spot 8°. Compare individual lens settings below..
  • IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Key specifications

SpecificationDetails
Identity numberL04025DP
Capacity4,000 W / 2,500 W
Lamp circuit200 V / 115 V
OpticØ335 mm protective lens; Ø300 mm PAR lens
LampHMI 4000W/SE or HMI 2500W/SE
Colour temperature5600 K
Lamp holderG38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature190 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object10 m
Minimum distance to flammable object1 m
Operating range+45° to -45°
Lamphead weight19.6 kg
Weight with barndoor22.1 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Photometrics are not safety clearances. FilmGear sets 10 m (32.8 ft) to illuminated objects and 1 m (3.3 ft) to flammable objects for the L04025DP. Model-specific datasheet.

Output Calculator

The calculator uses FilmGear readings from 10 to 20 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 10 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

Five interchangeable PAR lenses give a choice of field shape in either lamp class. Do not assume matching beam labels mean matching spread or illuminance across the two wattages.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the lens set to trade centre intensity for wider coverage.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration10 m15 m20 m
4,000 W · spot 8°57,318 lux25,474 lux14,329 lux
4,000 W · medium 10° × 20°22,574 lux10,033 lux5,643 lux
4,000 W · wide 20° × 45°7,838 lux3,479 lux1,957 lux
4,000 W · super wide 40°4,040 lux1,976 lux1,010 lux
4,000 W · frosted 36°2,677 lux1,190 lux669 lux
2,500 W · spot 8°54,288 lux24,128 lux13,572 lux
2,500 W · medium 10° × 20°17,827 lux7,923 lux4,457 lux
2,500 W · wide 20° × 45°3,384 lux1,504 lux846 lux
2,500 W · super wide 30°2,677 lux1,190 lux669 lux
2,500 W · frosted 35°1,326 lux589 lux332 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Use the table and calculator only with the stated lamp, optic and test configuration. The linked 2018 FilmGear sheet labels the 2,500 W wide lens 20° × 45°; an older 2012 FilmGear sheet labels it 20° × 40° with the same centre readings. Check the fitted lens rather than treating the spreads as interchangeable.

Back to contents

Power and Batteries

FilmGear lists 4kW/2.5kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Confirm the lamp wattage and install the lens named in the selected chart row. For an asymmetric lens, check which way the beam spreads on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Do not confuse L04025DP with the dual-wattage L04025DS Fresnel or the faceted L04000FP. Lens behavior, physical limits and photometry are head-specific.

What People Are Saying

Practical takeaways from FilmGear’s L04025DP specifications, not independent owner reviews.

What worked

  • The 4 kW 8° spot reaches a documented 57,318 lux at 10 m for a narrow daylight shaft.
  • The 10° × 20° medium flood gives an asymmetric beam to line up with the opening or bounce surface.
  • The five-lens case includes dedicated super-wide and frosted options, so the crew can choose a broader field without treating diffusion as a wattage setting.

Drawbacks to plan for

  • The 335 mm protective glass and 300 mm shaping lenses serve different functions. Keep the protective assembly intact and verify the actual lens case.
  • Use only the documented 4,000 W or 2,500 W single-ended lamp and matched ballast configuration. The 200 V/115 V figures are lamp-circuit voltages, not mains requirements.
  • The head is listed at 22.1 kg with doors. FilmGear specifies ±45° tilt and clearances of 10 m to the target and 1 m (3.3 ft) to flammables.

Videos

Illustrated fixture reference: FilmGear’s L04025DP drawing and accessory sheet shows the separate protective glass and five-lens case.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.