FilmGear Daylight Par Faceted F9k

Last Updated 21 hours ago

FilmGear F9k Overview

FilmGear Daylight Par Faceted F9k lamphead
FilmGear product photograph reproduced in the Carbone source for model identification.
FilmGear V3 9 kW / 6 kW electronic ballast front panel
9 kW / 6 kW ballast controlsFilmGear V3 300 Hz variant shown; confirm the ballast version in the actual kit. Photo: FilmGear.
OSRAM HMI Digital 9000 W single-ended GX38 lamp and base
9 kW GX38 lamp classOSRAM Digital 9 kW / 160 V GX38 shown as an example of the electrical and base class. It is separately sold, rated 6,000 K by OSRAM, and not claimed as the lamp behind FilmGear’s nominal 5,600 K or photometric figures. Photo: B&H.

The FilmGear Daylight Par Faceted F9k is a 9,000 W open-reflector HMI head with spot-to-flood focus behind a Ø500 mm UV protective lens. It requires a separate electronic ballast and matching head cable.

The separate 9 kW / 6 kW ballast does not make the single-wattage F9k a dual-wattage head. Use the documented 9 kW single-ended lamp class and observe FilmGear’s minimum distances.

Detail photo

  • Faceted HMI PAR Ø500 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
  • 9,000 W lamp + external ballast Lamp circuit: 160 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 35.0 kg lamphead; 40.0 kg with barndoor.
  • Beam Angle Spot 15°; Flood 54°.
  • IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

FilmGear F9k Specifications

SpecificationDetails
Identity numberL09000FP on the current family page; L0900FPS on the 2023 exact-model sheet
Capacity9,000 W
Lamp circuit160 V
OpticØ500 mm UV protective lens; focusable faceted reflector
LampHMI 9000W/SE
Colour temperature5600 K
Lamp holderGX38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature220 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object12 m
Minimum distance to flammable object2 m
Operating range+45° to -45°
Lamphead weight35.0 kg
Weight with barndoor40.0 kg
FilmGear primary documentation.

FilmGear’s current F-Series family page identifies the head as L09000FP, while the linked 2023 exact-model sheet prints L0900FPS. The 9,000 W capacity, 160 V lamp circuit, HMI 9000W/SE lamp, GX38 holder, optic, mount, clearances, weights and measurements agree. The identity suffix remains an explicit manufacturer-source discrepancy.

Output Calculator

The calculator uses FilmGear readings from 20 to 30 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 12 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The F9k can change beam width at the head without swapping a set of PAR spread lenses. Use it where there is room for the 40 kg head with barndoor, the remote ballast, cable, rated support and the prescribed clearance.

Practical Uses

UseWorking approach
Hard daylight punchSet the head toward spot for a distant subject. Check the beam width and meter the light at the subject before setting exposure.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration10 m20 m30 m
Spot 15°51,783 lux12,946 lux5,754 lux
Flood 54°7,775 lux1,944 lux864 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

FilmGear specifies a 12 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 20 to 30 m, with interpolation only inside that range. The 10 m row is retained as a published reference, not a permitted working distance.

Back to contents

Power and Batteries

FilmGear lists 9kW/6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use. The head’s rated maximum surface temperature is 220 °C; do not obstruct ventilation and allow the assembly to cool before moving or handling it.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Compare the F6k and F12k in FilmGear’s Faceted PAR family if lift, power or throw is the deciding factor. The F6k is a separate optical head; the larger F12k is not the same fixture with a 12 kW lamp.

What People Are Saying

The exterior example is explicitly identified by FilmGear; the other strengths and cautions come from the exact F9k factory sheet. None is an independent comparative test.

  • A documented exterior job FilmGear’s account names the F9k among the fixtures gaffer Mazi Mitchell used over months in coastal Georgia. It is the manufacturer’s account, not an independent weather or reliability test.
  • Large coverage change at 20 m FilmGear gives a 5.27 m spot diameter and a 20.38 m flood diameter at that throw. The head’s focus changes coverage without a spread-lens swap.
  • Useful spill and intensity controls The factory lists a rotatable four-leaf barndoor, spill ring, and 568 mm full and half scrims. The half scrims attenuate only part of the beam.
  • The nearest chart row is below working clearance FilmGear requires at least 12 m to the illuminated object. The factory’s 10 m row is retained for reference, not operation or calculator use.
  • A ballast rated for 6 kW is not an F6k conversion The shared electronic ballast accepts the intended separate head, but the F9k calls for the single-ended 9 kW lamp and its own reflector.
  • Check the suffix before choosing spares The US family lists L09000FP while the 2023 factory sheet says L0900FPS. Confirm the label, serial, connector and matching parts on the physical head.

Videos and Operating Reference

Read the FilmGear F9k operating reference. Check the head drawing, spigot, front assembly, clearance and lamp/ballast configuration. FilmGear’s F-Series demonstration covers the product family, not an exact F9k test.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.