FilmGear Daylight Par 6000W

Last Updated 21 hours ago

Daylight PAR 6000W Overview

FilmGear Daylight Par 6000W lamphead
FilmGear V3 6 kW external electronic ballast
6 kW V3 ballastFilmGear’s 6 kW V3 ballast shown separately. Photo: Film Gear USA.
OSRAM HMI DIGITAL 6,000 W single-ended GX38 discharge lamp
6 kW GX38 lampExample single-ended GX38 lamp of the relevant wattage. Use the exact lamp and connector specification on the rental head. Photo: B&H.

The FilmGear Daylight Par 6000W (L06000DP) is a 6 kW single-ended HMI PAR with 420 mm optics. The same head takes interchangeable spread lenses from an 8° spot to a 42° super-wide flood.

The 125 V rating is for the GX38 lamp circuit, not the mains input. FilmGear specifies 12 m to illuminated objects. Compare the lenses at the same distance and verify the ballast and head cable in the rental package.

Detail photo

  • HMI PAR Ø420 mm protective lens and PAR lens set; Ø28 mm / 1-1/8 in spigot.
  • 6,000 W lamp + external ballast Lamp circuit: 125 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 30.3 kg lamphead; 35.3 kg with barndoor.
  • Beam Angle Spot 8°; Medium 10° × 20°; Wide 20° × 40°; Super wide 42°; Frosted 36°.
  • IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Daylight PAR 6000W Specifications

SpecificationDetails
Identity numberL06000DP
Capacity6,000 W
Lamp circuit125 V
OpticØ420 mm protective lens and PAR lens set
LampHMI 6000W/SE
Colour temperature5600 K
Lamp holderGX38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature190 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object12 m
Minimum distance to flammable object1.5 m
Operating range+38° to -38°
Lamphead weight30.3 kg
Weight with barndoor35.3 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

The calculator uses FilmGear readings from 15 to 25 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 12 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

Five separate 420 mm PAR optics provide predictable changes in shape. The original L06000DP is a fixed-wattage lamphead with matching external control gear, and changes require the correct lens kit.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the lens set to trade centre intensity for wider coverage.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration15 m20 m25 m
Spot 8°49,491 lux27,839 lux17,817 lux
Medium 10° × 20°18,966 lux10,669 lux6,828 lux
Wide 20° × 40°7,238 lux4,071 lux2,606 lux
Super wide 42°3,860 lux2,172 lux1,390 lux
Frosted 36°2,313 lux1,301 lux833 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.

Back to contents

Power and Batteries

FilmGear lists 12kW/6kW, 9kW/6kW or 6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Use the fitted lens for the beam in the table. Compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Choose the F6k Faceted PAR if variable focus is more useful than swappable beam patterns. Choose the L06000DS Fresnel if you need that model’s optical character. None of their optic charts substitutes for this L06000DP’s five-lens set.

What People Are Saying

Videos

No exact operating footage was verified. FilmGear’s Daylight PAR 6000W technical sheet is a written source for the model, lamp, optics and matching equipment.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.