Last Updated 21 hours ago
Daylight PAR 6000W Overview



The FilmGear Daylight Par 6000W (L06000DP) is a 6 kW single-ended HMI PAR with 420 mm optics. The same head takes interchangeable spread lenses from an 8° spot to a 42° super-wide flood.
The 125 V rating is for the GX38 lamp circuit, not the mains input. FilmGear specifies 12 m to illuminated objects. Compare the lenses at the same distance and verify the ballast and head cable in the rental package.
- HMI PAR Ø420 mm protective lens and PAR lens set; Ø28 mm / 1-1/8 in spigot.
- 6,000 W lamp + external ballast Lamp circuit: 125 V. This is not the ballast mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 30.3 kg lamphead; 35.3 kg with barndoor.
- Beam Angle Spot 8°; Medium 10° × 20°; Wide 20° × 40°; Super wide 42°; Frosted 36°.
- IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.
Daylight PAR 6000W Specifications
| Specification | Details |
|---|---|
| Identity number | L06000DP |
| Capacity | 6,000 W |
| Lamp circuit | 125 V |
| Optic | Ø420 mm protective lens and PAR lens set |
| Lamp | HMI 6000W/SE |
| Colour temperature | 5600 K |
| Lamp holder | GX38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 190 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 12 m |
| Minimum distance to flammable object | 1.5 m |
| Operating range | +38° to -38° |
| Lamphead weight | 30.3 kg |
| Weight with barndoor | 35.3 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 15 to 25 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 12 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
Five separate 420 mm PAR optics provide predictable changes in shape. The original L06000DP is a fixed-wattage lamphead with matching external control gear, and changes require the correct lens kit.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the lens set to trade centre intensity for wider coverage. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 15 m | 20 m | 25 m |
|---|---|---|---|
| Spot 8° | 49,491 lux | 27,839 lux | 17,817 lux |
| Medium 10° × 20° | 18,966 lux | 10,669 lux | 6,828 lux |
| Wide 20° × 40° | 7,238 lux | 4,071 lux | 2,606 lux |
| Super wide 42° | 3,860 lux | 2,172 lux | 1,390 lux |
| Frosted 36° | 2,313 lux | 1,301 lux | 833 lux |
Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.
Power and Batteries
FilmGear lists 12kW/6kW, 9kW/6kW or 6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Use the fitted lens for the beam in the table. Compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Choose the F6k Faceted PAR if variable focus is more useful than swappable beam patterns. Choose the L06000DS Fresnel if you need that model’s optical character. None of their optic charts substitutes for this L06000DP’s five-lens set.
What People Are Saying
These observations come from FilmGear’s exact model documentation, not independent operator reviews.
Strengths
- At 20 m the 8° Spot optic provides 27,839 lux in a roughly 2.8 m beam, useful for a tight daylight accent.
- At 20 m the 20° × 40° Wide Flood covers roughly 7.05 × 14.46 m, useful for a long window bank or a wide bounce.
- The 495 mm full and half scrims can trim level or cut part of the beam without changing to another lens.
Limitations
- Wide coverage costs centre output: 4,071 lux in Wide Flood versus 27,839 lux in Spot at 20 m. Take a new reading after a lens swap.
- FilmGear lists a 12 m subject clearance and 1.5 m from flammable objects; the calculator itself is limited to 15–25 m.
- A ballast that supports 12/6 or 9/6 kW does not make this a dual-wattage head. Confirm L06000DP, its 6 kW SE GX38 lamp and matched feeder.
Videos
No exact operating footage was verified. FilmGear’s Daylight PAR 6000W technical sheet is a written source for the model, lamp, optics and matching equipment.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.