FilmGear Daylight Par Faceted F18k

Last Updated 21 hours ago

Overview

FilmGear Daylight Par Faceted F18k lamphead
FilmGear product photograph reproduced in the Carbone source for model identification.
FilmGear V3 18 kW / 12 kW electronic ballast front panel and transport wheels
18 kW / 12 kW ballast controlsFilmGear V3 ballast shown in the manufacturer’s photograph; confirm the version and connectors supplied with the head.
Crew member adjusts a FilmGear F18k positioned beside a ladder outdoors
F18k on locationThe F18k on location, showing the working size of the head and support. Photo: Adorama product gallery.

The FilmGear Daylight Par Faceted F18k is an 18,000 W open-reflector HMI head with spot-to-flood focus behind a Ø645 mm UV protective lens. It requires a separate electronic ballast and matching head cable.

FilmGear lists a separate 18 kW / 12 kW electronic ballast and a matched head cable. The dual-rated ballast does not make this F18k head a dual-wattage model. Observe the documented working clearances.

Detail photo

  • Faceted HMI PAR Ø645 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
  • 18,000 W lamp + external ballast Lamp circuit: 225 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 66.0 kg lamphead; 72.0 kg with barndoor.
  • Beam Angle Spot 15°; Flood 50°.
  • IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Key Specifications

SpecificationDetails
Identity numberL18000FP on the current family page; L1800FPS on the 2025 exact-model sheet
Capacity18,000 W
Lamp circuit225 V
OpticØ645 mm UV protective lens; focusable faceted reflector
LampHMI 18000W/SE
Colour temperature5600 K
Lamp holderGX51
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature260 °C
Maximum ambient temperature45 °C in the FilmGear USA F18k technical listing; not stated in the 2025 L1800FPS sheet
Minimum distance to illuminated object15 m
Minimum distance to flammable object2 m
Operating range+45° to -45°
Lamphead weight66.0 kg
Weight with barndoor72.0 kg
FilmGear primary documentation.

FilmGear’s current F-Series family page identifies the head as L18000FP, while the linked January 2025 exact-model sheet prints L1800FPS. Both current sources specify a 225 V lamp circuit; an older sheet printed 200 V. Capacity, HMI 18000W/SE lamp, GX51 holder, optic, mount, clearances, weights and current measurements otherwise agree. The identity suffix remains open, while 225 V is the supported current value.

Photometrics are not safety clearances. For this F18k, FilmGear specifies 15 m (49.2 ft) to illuminated objects and 2 m (6.6 ft) to flammable objects. Model-specific specification sheet.

Output Calculator

The calculator uses FilmGear readings from 15 to 30 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The faceted reflector shifts from a 15° spot to a 50° flood without a converter-lens swap. The 645 mm UV protective assembly remains required.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

The numbers below reproduce the 2025 L1800FPS sheet. Its 15 m values do not scale consistently from the 20 m and 30 m rows, notably in flood. Do not replace them with inferred numbers or use the calculator estimate instead of metering the shot. The dedicated US F18k page and 2025 sheet both list a 225 V lamp circuit, despite the 200 V value on the general F Series overview. Verify the lamp and nameplate on the actual head.

Configuration15 m20 m30 m
Spot 15°50,618 lux32,490 lux14,440 lux
Flood 50°9,476 lux3,365 lux1,495 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

FilmGear specifies a 15 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 15 to 30 m, with interpolation only inside that range. Any closer rows in the archival table are reference readings, not permitted working distances. The published readings do not follow a single inverse-square curve; values between them are interpolated estimates, not additional manufacturer measurements. No source reading has been corrected.

Back to contents

Power and Batteries

FilmGear lists 18kW/12kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Match the F18k plate to the documentation: FilmGear USA lists L18000FP and the 2025 factory sheet identifies L1800FPS. Do not compare against the 18/12 kW Power Beam or double-ended Fresnel as if they used the same head or lamp.

What People Are Saying

Practical takeaways from FilmGear’s F18k specifications, not independent owner reviews.

What worked

  • The 15° spot is documented at 32,490 lux at 20 m across a 5.3 m field for a long-throw daylight key.
  • At 20 m the 50° flood covers 18.7 m before modifiers, without changing converter lenses.
  • The maker lists 737 mm full and half scrims and rotating doors with a safety wire to shape or trim the beam.

Drawbacks to plan for

  • At 72 kg with doors and up to 260°C listed surface temperature, this fixture requires qualified rigging and clearance planning.
  • The documented light uses the 18 kW single-ended GX51 lamp. The 18/12 kW ballast label does not make this a dual-wattage head.
  • FilmGear sets 15 m to illuminated objects and 2 m to flammables; do not substitute distances from an F12k, Fresnel or Power Beam.

Videos

Illustrated fixture reference: FilmGear’s F18k drawing and accessory sheet shows the head, protective optics and model-specific package.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.