FilmGear Daylight Par 12000W

Last Updated 21 hours ago

Overview

FilmGear Daylight Par 12000W lamphead
FilmGear V3 12 kW/6 kW electronic ballast
12 kW/6 kW ballastOne of the external ballast families FilmGear specifies for the 12 kW PAR. Photo: Film Gear USA.
OSRAM HMI 12,000 W/SE XS, GX38 single-ended discharge lamp
Single-ended 12 kW lampExample GX38 single-ended 12 kW lamp. It is not interchangeable with the double-ended version. Photo: ProLampSales.

The FilmGear Daylight Par 12000W (L12000DP) is a 12 kW single-ended HMI PAR with a 500 mm protective lens and interchangeable 500 mm PAR lenses. The bare head weighs 50.7 kg.

The GX38 lamp circuit is rated 160 V. Match the separate ballast and head cable to the fixture and use the ballast nameplate to plan mains power. Do not substitute the double-ended 12 kW lamp used by a different head.

Detail photo

  • HMI PAR Ø500 mm protective lens and PAR lens set; Ø28 mm / 1-1/8 in spigot.
  • 12,000 W lamp + external ballast Lamp circuit: 160 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 50.7 kg lamphead; 56.3 kg with barndoor.
  • Beam Angle Spot 9°; Medium 10° × 20°; Wide 20° × 40°; Super wide 42°; Frosted 36°.
  • IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Key specifications

SpecificationDetails
Identity numberL12000DP
Capacity12,000 W
Lamp circuit160 V
OpticØ500 mm protective lens and PAR lens set
LampHMI 12000W/SE
Colour temperature5600 K
Lamp holderGX38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature220 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object15 m
Minimum distance to flammable object2 m
Operating range+30° to -30°
Lamphead weight50.7 kg
Weight with barndoor56.3 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Photometrics are not safety clearances. For this L12000DP, FilmGear specifies 15 m (49.2 ft) to illuminated objects and 2 m (6.6 ft) to flammable objects. Model-specific specification sheet.

Output Calculator

The calculator uses FilmGear readings from 20 to 40 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The 500 mm lens set offers five fields for a distant hard key or broad backing. Unlike the faceted F12k, this head changes its beam with separate PAR lenses.

Practical Uses

UseWorking approach
Hard daylight punchStart with the narrowest documented beam setup for a distant subject. Check beam width and meter the light at the subject before setting exposure.
Beam shapingUse the lens set to trade centre intensity for wider coverage.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

The following values and the calculator use the 2018 L12000DP chart, restricted to 20–40 m. The manufacturer’s 15 m minimum is an operating limit, not a published 15 m reading for the current chart.

Configuration20 m30 m40 m
Spot 9°41,410 lux18,404 lux10,353 lux
Medium 10° × 20°14,266 lux6,341 lux3,567 lux
Wide 20° × 40°4,621 lux2,054 lux1,155 lux
Super wide 42°2,525 lux1,122 lux631 lux
Frosted 36°2,200 lux978 lux550 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.

Back to contents

Power and Batteries

FilmGear lists 18kW/12kW or 12kW/6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Use the fitted lens for the beam in the table. Compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

The L12000FP F12k faceted PAR and L12000DS 12 kW Fresnel are separate heads. The data here are for the L12000DP interchangeable-lens PAR with the 2018 chart, not a mixed-family average.

What People Are Saying

Practical takeaways from FilmGear’s L12000DP specifications, not independent owner reviews.

What worked

  • The 9° spot produces 41,410 lux at 20 m, a useful reference for a defined long-throw source.
  • The 10° × 20° medium and 20° × 40° wide lenses offer separate asymmetric fields for a window or large bounce.
  • The factory lens case includes five optics, including distinct super-wide and frosted options.

Drawbacks to plan for

  • At 56.3 kg with doors and ±30° operating tilt, verify the actual support geometry and full package weight before booking.
  • The 500 mm protective glass and 500 mm optical lenses perform separate jobs; confirm both are the exact intact parts.
  • The current GX38 sheet is for a 12 kW single-ended, 160 V lamp circuit. Do not apply an older catalogue’s G38 designation or treat the lamp voltage as mains input.

Videos

Illustrated fixture reference: FilmGear’s L12000DP drawing and accessory sheet shows the head, protective optics and model-specific package.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.