Last Updated 21 hours ago
Daylight Fresnel 18kW/12kW DE Overview



The FilmGear Daylight Fresnel 18k/12k DE (L18012DD) is a dual-wattage HMI head with a 625 mm Fresnel lens. It takes double-ended lamps and weighs 92 kg before doors, cabling or ballast.
The two lamp configurations require the matched 18/12 kW ballast and head cable. The 225 V and 160 V figures apply to the 18 kW and 12 kW lamp circuits, not directly to the mains feed. Use each output table only for its stated wattage.
- Double-ended HMI Fresnel Ø625 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
- 18,000 W / 12,000 W lamp + external ballast Lamp circuit: 225 V / 160 V. This is not the ballast mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 92.0 kg lamphead; 98.8 kg with barndoor.
- Beam Angle Spot 8°; Flood 50°.
- IP RatingIP20 Lamphead; ballast and cable ratings are separate. Read the IP Rating.
Daylight Fresnel 18kW/12kW DE Specifications
| Specification | Details |
|---|---|
| Identity number | L18012DD |
| Capacity | 18,000 W / 12,000 W |
| Lamp circuit | 225 V / 160 V |
| Optic | Ø625 mm Fresnel |
| Lamp | HMI 18000W/DE or HMI 12000W/DE |
| Colour temperature | 5600 K |
| Lamp holder | Double-ended, spring-loaded holder |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP20 |
| Maximum surface temperature | 230 °C |
| Maximum ambient temperature | Not stated on the exact-model sheet |
| Minimum distance to illuminated object | 15 m |
| Minimum distance to flammable object | 2 m |
| Operating range | +30° to -30° |
| Lamphead weight | 92.0 kg |
| Weight with barndoor | 98.8 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 15 to 35 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The 625 mm Fresnel gives a continuous change in coverage while the head supports either of its specified double-ended lamp configurations. Plan the lamp, ballast and distribution as a package and observe the 15 m illuminated-object clearance.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 15 m | 25 m | 35 m |
|---|---|---|---|
| 18,000 W · spot 8° | 43,273 lux | 15,578 lux | 7,948 lux |
| 18,000 W · flood 50° | 5,746 lux | 2,068 lux | 1,055 lux |
| 12,000 W · spot 8° | 36,629 lux | 13,187 lux | 6,728 lux |
| 12,000 W · flood 50° | 3,412 lux | 1,228 lux | 627 lux |
Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.
Power and Batteries
FilmGear lists 18kW/12kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the dedicated single-ended 12 kW FilmGear Fresnel if your package uses an SE lamp. The 18/12 kW DE head is not that fixture, and the Faceted PAR series uses different optics and data.
What People Are Saying
These observations come from FilmGear’s exact model documentation, not independent operator reviews.
Strengths
- At 25 m the 18 kW lamp in 8° Spot gives 15,578 lux; the 12 kW Spot result at that throw is 13,187 lux. FilmGear publishes both modes separately.
- The 50° Flood setting changes beam coverage with the Fresnel focus, without buying a separate spread-lens kit.
- FilmGear lists rotatable doors and full and half 737 mm scrims to control spill and level without changing the focus.
Limitations
- Changing wattage does not scale all beams equally: at 25 m FilmGear lists 2,068 lux in 18 kW Flood versus 1,228 lux in 12 kW Flood. Re-meter the fitted lamp.
- The linked sheet lists IP20, a 15 m illuminated-object minimum and 2 m from flammable objects. Plan a dry site and enough clearance.
- The 92 kg head rises to 98.8 kg with doors, before cable support; use the specified 28 mm mount and verify total supported load.
Videos
No exact operating footage was verified. FilmGear’s Daylight Fresnel 18kW/12kW DE technical sheet is a written source for the model, lamp, optics and matching equipment.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.