Last Updated 4 days ago
ARRILITE 600 Overview



The ARRI ARRILITE 600 is a focusing, open-face tungsten light, catalogue number 571600. Its 5-inch scrim holder takes ARRI’s 531350 full single and 531352 full double. At 10 ft, opening the beam from spot to flood drops the centre reading from 240 to 63 fc.
It fits a 5/8-inch stand stud and weighs 1.6 kg with its switched cable.
- Focusing open-face tungsten; 5 in scrims
- 600 W DYS reference
- Colour TemperatureLamp-dependent tungsten; DYS test 600 W/120 V
- Weight1.6 kg with switched cable
- Beam Angle34° spot / 90° flood with DYS
- IP RatingNot documented for 571600 Read the IP Rating.
ARRILITE 600 Specifications
This head uses a GY9.5 socket and 5 in scrims. The ARRI 600 manual also names DYR. Check its voltage and the head rating before fitting it.
| Lamp | Power | Rated voltage |
|---|---|---|
| DYS | 600 W | 120 V |
| EKB | 420 W | 120 V |
| DYG | 250 W | 30 V |
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
- Focusing the reflector gives a useful spread range without swapping optics: 34° spot to 90° flood in the DYS test.
- The 5-inch holder takes full and half scrims for level control without the warmer colour of electrical dimming.
- The open face is good for bounce and broad coverage, but it is not a Fresnel and can spill more; quartz lamps and nearby accessories run hot.
- Check the circuit, voltage and spare lamp for the exact head. The useful 30 V catalogue option is not a mains lamp.
Practical Uses
Use flood into a close bounce; use spot to reach a smaller patch.
For a warm interior bounce, start at flood for coverage, then move the head closer only as needed. For a harder edge, use spot and trim the spill with the doors or separate flags. At the same throw, changing to spot raises the centre reading but lights a smaller patch.
Output and Colour
ARRI measured the DYS at 600 W and 120 V. The values below are in foot-candles.
| Throw | Spot at 34° | Flood at 90° |
|---|---|---|
| 5 ft | 960 | 250 |
| 10 ft | 240 | 63 |
| 15 ft | 106 | 28 |
| 20 ft | 60 | 16 |
Power and Batteries
The 571600 is shown with an 11.5 ft switched cable. A 600 W, 120 V DYS draws 5 A at rated voltage. Use the exact lamp and voltage on the nameplate; the shared ARRI manual also mentions other voltage variants, not interchangeable mains lamps.
Control, Cooling and Camera Operation
Use the manual focus to change beam width and the in-line switch for power. The lamp, not a menu, sets the rated colour temperature. An external tungsten dimmer warms the lamp as it dims; use a compatible wire scrim to reduce level without warming it, or CTB if you need to raise the colour temperature.
Modifiers, Rigging and the Working Package
ARRI’s 571610 four-leaf barndoors and 571620 safety glass are listed separately in the 571600 catalogue. Confirm the holder and required lamp protection before use. Do not close the barndoors while the head is on; ARRI warns against this in its operating manual.
Alternatives and Related Fixtures
Compare a 650 W tungsten Fresnel when you need a more controlled beam edge. Do not read ARRILITE 800/800 Plus output or accessory fit across to this 5-inch 571600 head; the model and lamp need to match the paperwork.
What People Are Saying
Filmmaker Bill Holshevnikoff demonstrates the exact ARRILITE 600 for ARRI; that is a named manufacturer-hosted walkthrough, not an independent review. A discussion comparing used 600 and 800 kits raises two practical buying questions: whether the open face is strong enough at the intended throw, and whether scrims and spill control are in the package. The responses do not identify a controlled 571600 test.
Videos
Bill Holshevnikoff’s ARRILITE 600 walkthrough, published by ARRI.
Rental and Used-Fixture Checks
Before You Book
Confirm DYS markings, 5 in scrims and switched lead; DYG 30 V is not a mains substitute.
Ask for a cold inspection of the 5-inch accessory ring, safety mesh, lamp socket and switched lead. Confirm voltage and spare lamp; test full spot and flood before the unit leaves prep.
Documentation and Specifications
ARRI Lighting catalogue, printed page 31 · Model 571600 product photograph · ARRILITE 600 instruction manual · Ushio EKB specifications