ETC Source Four Mini LV (Tungsten)

Last Updated 4 days ago

Source Four Mini LV Overview

ETC Source Four Mini tungsten profile fixture
ETC 26-degree lens tube for the Source Four Mini
26° lens tubeOne of four Source Four Mini lens-tube options. This is separate from the MR16 lamp. Photo: B&H.
ETC 7063A2010 E-size pattern holder for the Source Four Mini
E-size gobo holderThe Source Four Mini takes the 7063A2010 E-size pattern holder. It differs from the Irideon FPZ holder. Photo: Leisuretec.

The ETC Source Four Mini LV is a 12 V, 50 W tungsten profile with framing shutters, an E-size pattern slot and interchangeable lens tubes. It uses a remotely supplied Class 2 feed rather than an onboard transformer.

The 19°, 26°, 36° and 50° lens tubes shape the projected field. The separate 35° MR16 lamp specification does not describe the beam angle on the set. The portable, canopy and track models have different power arrangements.

Detail photo

  • Fixture Type Low-voltage tungsten profile · Source Four Mini LV
  • Power 50 W shielded MR16 / 12 V via external Class 2 feed.
  • Colour Temperature 3,000 K with ETC’s specified Ushio Eurostar IR.
  • Weight 1.1 kg / 2.4 lb, published fixture weight.
  • Beam Angle 19°, 26°, 36° or 50° lens tubes; 35° is the lamp spread.
  • IP Rating Dry locations only; no numerical IP rating verified for the LV head. Read the IP Rating.

Jump to Output Calculator ↓

Source Four Mini LV Specifications

  • 50 W, 12 V shielded MR16 source, GU5.3 base
  • ETC factory lamp specification: Ushio Eurostar IR, 35° lamp spread, 3000 K, 5,000-hour average life
  • Interchangeable 19°, 26°, 36° and 50° lens tubes
  • 2.75 in / 70 mm media frame
  • External 12 V Class 2 power feed for the LV model
  • Four shutters and E-size pattern holder
Lamp and Lens Distinction: ETC specifies a 35° MR16 lamp behind separate 19°, 26°, 36° and 50° lens tubes. The lamp spread is not the fixture’s projected field angle.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

This small profile has four shutters and interchangeable lens tubes for defined cuts and small patterns. It gives less centre light with the wider tube, and the LV head needs a separate 12 V Class 2 supply.

Practical Uses

Use it to pick out a small set detail, cut a slot across a wall or project an E-size pattern. Choose the tube for the size of the target at the actual throw, then set the projection edge with the focus control.

Output and Colour

ETC’s Mini LV datasheet gives four tested distances for every lens tube. The calculator retains the published rounded metric distances and lux readings over 3.0–9.1 m. The table’s 10/15/20/30 ft distances are paired in the datasheet with 3.0/4.6/6.1/9.1 m. Intermediate results are estimates, not additional factory measurements.

Lens tubePeak candelaDistancesFoot-candlesLux
19°8,830 cd10 / 15 / 20 / 30 ft88.3 / 39.2 / 22.1 / 9.8 fc950 / 422 / 238 / 106 lux
26°5,500 cd10 / 15 / 20 / 30 ft55.0 / 24.4 / 13.8 / 6.1 fc592 / 263 / 148 / 66 lux
36°3,030 cd10 / 15 / 20 / 30 ft30.3 / 13.5 / 7.6 / 3.4 fc326 / 145 / 82 / 36 lux
50°1,940 cd10 / 15 / 20 / 30 ft19.4 / 8.6 / 4.9 / 2.2 fc209 / 93 / 52 / 23 lux

Power and Batteries

The LV model accepts a 12 V Class 2 feed and is dimmable with a suitable external 12 V dimmer. Portable, canopy and track versions use ETC’s integrated or yoke-mounted transformer arrangement. A plug adapter does not replace the required transformer or Class 2 supply.

Control, Cooling and Camera Operation

The four shutters and mechanical focus set the shape and edge. Dimming the tungsten lamp shifts it warmer; check white balance and exposure at the dim level used on camera. ETC specifies dry locations only and warns that the lens, housing and lamp get hot.

Modifiers, Rigging and the Working Package

Lens TubeMeasured Beam AngleMeasured Field AngleField Diameters at 3.0 / 4.6 / 6.1 / 9.1 m
19° · 4M19LT14.10°19.54°1.0 / 1.6 / 2.1 / 3.1 m
26° · 4M26LT18.20°25.80°1.4 / 2.1 / 2.8 / 4.2 m
36° · 4M36LT25.2°35.3°1.9 / 2.9 / 3.9 / 5.8 m
50° · 4M50LT32.2°48.0°2.7 / 4.1 / 5.4 / 8.1 m

The E-size holder accepts 37.5 mm patterns with a 25.4 mm image area, up to 1.27 mm thick. The shutter assembly rotates ±175°. ETC lists a 1.1 kg fixture weight and 0–50°C ambient operating range. The LV package includes lamp, holder, barrel and yoke; lens tubes and mounting accessories are separate. Source: ETC Mini LV datasheet, Rev. E (September 2016), pages 1–6.

Alternatives and Related Fixtures

Choose the full-size tungsten Source Four for larger or longer-throw projection. The line-voltage tungsten Mini and Mini LED are distinct fixtures; neither uses this exact 12 V installation specification.

What People Are Saying

These practical notes come from ETC’s legacy tungsten documentation and its Mini Low Voltage setup instructions. The Source Four Mini LED and line-voltage Mini have different power requirements.

What Works

  • Compact 12 V profile: The 1.1 kg LV head can fit small displays or set details while retaining real shutters and a focusable pattern gate.
  • Tiny projections with E-size patterns: The E-size holder and rotating shutter barrel let you shape or align a small patch of light without bringing in a full-size Source Four.
  • Choose coverage by lens: At 10 ft, ETC’s table lists 950 lux at centre with the 19° tube and 209 lux with the 50° tube. Choose the wide tube for coverage, not for the same centre level.

What to Watch For

  • Low voltage only: The bare-ended LV feed is intended for a 12 V Class 2 system. It is not the portable line-voltage version with a transformer mounted on its yoke.
  • Lens tube is separate: ETC says the LV fixture needs a separately supplied Mini lens tube. Confirm that the head, tube, lamp and supply are all in the package before load-in.
  • Tungsten colour only: The MR16 lamp is not tunable. Use CTB gel to move it toward daylight and allow for the resulting light loss, or start with a different fixture.

Videos

The ETC Source Four Mini Low Voltage user manual shows the LV head, its lens tube, yoke and mounting choices, and identifies the separate low-voltage feed. Other tungsten Mini variants use different power arrangements.

Rental and Used-Fixture Checks

Confirm the LV marking, the matching 12 V Class 2 supply and the separately supplied lens tube. Check the shielded MR16 lamp, shutter travel, pattern holder, colour-frame retainer and mounting hardware before installation.

Documentation and Specifications

Full-size ETC Source Four · browse ETC fixtures · tungsten lights