Daylight Fresnel 1.8kW/1.2kW SE Overview



The FilmGear Daylight Fresnel 1.8k/1.2k (L01812DS) is a dual-wattage HMI Fresnel with a 175 mm lens. FilmGear publishes a 5° spot and 52° flood; the head weighs 9.7 kg bare.
Select either the 1,800 W or 1,200 W G38 lamp and match the ballast setting and head cable. The 140 V and 100 V figures apply to the lamp circuit. This is the Fresnel, not the interchangeable-lens 1.8k/1.2k PAR.
- Daylight HMI Fresnel Ø175 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
- 1,800 W / 1,200 W lamp + external ballast G38. 140 V / 100 V belongs to the lamp circuit, not mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 9.7 kg lamphead; 10.7 kg with barndoor.
- Beam Angle Spot 5°; Flood 52°.
- IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.
Daylight Fresnel 1.8kW/1.2kW SE Specifications
| Specification | Details |
|---|---|
| Identity number | L01812DS |
| Capacity | 1,800 W / 1,200 W |
| Lamp circuit | 140 V / 100 V |
| Optic | Ø175 mm Fresnel |
| Lamp | CSR 1800W/SE/HR or HMI 1800W/SE; MSR 1200HR or HMI 1200W/SE |
| Colour temperature | 5600 K |
| Lamp holder | G38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 180 °C / 170 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 6 m |
| Minimum distance to flammable object | 0.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 9.7 kg |
| Weight with barndoor | 10.7 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 6 to 9 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 6 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The same Fresnel package is factory-specified for 1,800 W and 1,200 W single-ended lamps. Choose the mode for the actual beam, not wattage alone: FilmGear’s 1,800 W table is brighter in flood but lower at spot centre. The head requires the matched ballast and a long working distance.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 3 m | 6 m | 9 m |
|---|---|---|---|
| 1,800 W · spot 5° | 90,000 lux | 20,000 lux | 9,000 lux |
| 1,800 W · flood 52° | 12,000 lux | 3,200 lux | 1,500 lux |
| 1,200 W · spot 5° | 102,403 lux | 25,601 lux | 11,378 lux |
| 1,200 W · flood 52° | 7,799 lux | 1,950 lux | 867 lux |
The table keeps FilmGear’s published test readings. At 6 m the 1,200 W spot is brighter at centre (25,601 vs 20,000 lx), but the 1,800 W flood is brighter (3,200 vs 1,950 lx). FilmGear does not give a measured reason for that reversal. Distances below the stated minimum are reference measurements only and are not available in the calculator.
Power and Batteries
The 2025 L01812DS sheet specifies the V3 1.8kW/1.2kW/575W electronic ballast. A 1.2kW/575W ballast cannot operate a 1,800 W lamp; that smaller ballast is listed on the separate dedicated 1,200 W Fresnel sheet. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
The exact FilmGear sheet lists 229 mm full and half scrims, a rotating four-leaf door, a filter frame and 7 m or 15 m head leads. Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the dedicated L01200DS if you only need 1,200 W operation. For a PAR beam, choose a dedicated daylight PAR with its own optical and accessory specifications.
What People Are Saying
Field Feedback at a Glance
The FilmGear L01812DS model sheet documents these specific capabilities and working limits. They are not independent owner reviews.
What worked
- Two supported lamp powers: the L01812DS sheet separately lists 1,800 W and 1,200 W SE lamp choices on the G38 interface.
- Wider-area output with the 1,800 W lamp: at 6 m the 52° flood measures 3,200 lux.
- Common fixture package across modes: the 175 mm Fresnel, 28 mm spigot and 229 mm front accessories stay with this exact head.
Drawbacks to plan for
- Check the actual lamp and ballast pairing; the 140 V and 100 V figures are lamp-circuit values, not mains input.
- Do not assume a 1,800 W lamp is brighter everywhere. Its centre spot result is lower than the published 1,200 W spot result.
- Keep the 6 m minimum to illuminated objects. The factory’s 3 m reading is reference only and is excluded from the calculator.
Videos
Use the illustrated FilmGear L01812DS fixture sheet for the exact Fresnel, yoke, door, head cable and lamp options. It identifies this head without relying on footage of the PAR or another fixture from the family.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.