FilmGear Daylight Fresnel 12000W SE

Last Updated 21 hours ago

Daylight Fresnel 12000W SE Overview

FilmGear Daylight Fresnel 12000W SE lamphead
FilmGear V3 12 kW/6 kW electronic ballast
12 kW V3 ballastCompatible-wattage FilmGear V3 ballast option, shown on its own. Photo: Film Gear USA.
OSRAM HMI 12,000 W/SE XS GX38 discharge lamp
Single-ended 12 kW lampExample of the 12 kW GX38 single-ended lamp. This is not the 12 kW double-ended lamp. Photo: ProLampSales.

The FilmGear Daylight Fresnel 12000W SE (L12000DS) is a 12 kW single-ended HMI Fresnel with a 500 mm lens and a 6°–54° published focus range. The head weighs 51 kg without doors, cable or ballast.

It uses a single-ended GX38 lamp and a compatible external ballast. The 160 V figure is the lamp-circuit rating, not the mains requirement. FilmGear specifies 15 m minimum to illuminated objects.

Detail photo

  • HMI Fresnel Ø500 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
  • 12,000 W lamp + external ballast Lamp circuit: 160 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 51.0 kg lamphead; 55.5 kg with barndoor.
  • Beam Angle Spot 6°; Flood 54°.
  • IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Daylight Fresnel 12000W SE Specifications

SpecificationDetails
Identity numberL12000DS
Capacity12,000 W
Lamp circuit160 V
OpticØ500 mm Fresnel
LampMSR 12000HR or HMI 12000W/SE
Colour temperature5600 K
Lamp holderGX38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature200 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object15 m
Minimum distance to flammable object2 m
Operating range+38° to -38°
Lamphead weight51.0 kg
Weight with barndoor55.5 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

The calculator uses FilmGear readings from 15 to 35 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The 500 mm Fresnel gives a defined 6° spot and a broad 54° flood. Plan for a separate 12 kW-capable ballast, rated crew handling and at least 15 m to illuminated objects.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration15 m25 m35 m
Spot 6°39,727 lux14,302 lux7,297 lux
Flood 54°2,397 lux863 lux440 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.

Back to contents

Power and Batteries

FilmGear lists 18kW/12kW or 12kW/6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

FilmGear’s exact model sheet lists 622 mm (24½ in) scrims and a 15 m or 20 m head lead. Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Compare the 9/6 kW Fresnel if a smaller SE head meets the required output. Use the exact 12 kW PAR or 18/12 kW DE Fresnel chart only when that fixture, lamp and configuration are actually specified.

What People Are Saying

Videos

Use the illustrated FilmGear L12000DS fixture sheet for the actual Fresnel head and accessory package. It distinguishes this head from the similarly rated PAR, Power Beam and double-ended equipment.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.