Daylight Fresnel 1200W SE Overview



The FilmGear Daylight Fresnel 1200W SE is a 1.2 kW single-ended HMI with a 175 mm Fresnel and a published 5°–52° spot-to-flood range. The bare head weighs 9.7 kg.
It uses a G38 lamp and separate compatible ballast. The listed 100 V lamp-circuit figure is not the mains requirement. Select a lens or modifier for this Fresnel, not the 1.8/1.2 kW PAR.
- Daylight HMI Fresnel Manual-focus daylight Fresnel; Ø175 mm / 6-7/8 in Fresnel; Ø28 mm / 1-1/8 in spigot.
- 1,200 W lamp + external ballast G38. Use the matched ballast. 100 V belongs to lamp circuit, not mains.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 9.7 kg lamphead; 10.7 kg with barndoor.
- Beam Angle Spot 5°; Flood 52°.
- IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.
Daylight Fresnel 1200W SE Specifications
| Specification | Details |
|---|---|
| Identity number | L01200DS |
| Capacity | 1,200 W |
| Lamp circuit | 100 V |
| Optic | Ø175 mm / 6-7/8 in Fresnel |
| Lamp | MSR 1200HR or HMI 1200W/SE |
| Colour temperature | 5600 K |
| Lamp holder | G38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 180 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 6 m |
| Minimum distance to flammable object | 0.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 9.7 kg |
| Weight with barndoor | 10.7 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
Calculator range: 6–9 m (19.7–29.5 ft). The tool estimates only between published measurements. Stay at least 6 m from the illuminated object, or farther if the unit’s instructions require it.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
A 5° spot gives a hard daylight pool from across a set, while 52° flood covers a wider target. This is the dedicated 1,200 W SE Fresnel, not the PAR or dual-wattage head. It needs a ballast, head cable and at least 6 m to the illuminated object.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
The 5° spot and 52° flood readings belong to this Fresnel, not the 1200W PAR. Leave space for the 6 m object clearance when planning a wider wash.
Output and Colour
FilmGear measured the centre of the beam for each configuration below.
| Configuration | 3 m | 6 m | 9 m |
|---|---|---|---|
| Spot 5° | 102,403 lux | 25,601 lux | 11,378 lux |
| Flood 52° | 7,799 lux | 1,950 lux | 867 lux |
The closest reading in the table is below FilmGear’s 6 m illuminated-object clearance. It is shown for reference only and is not available in the calculator.
Power and Batteries
FilmGear lists 1.8kW/1.2kW/575W or 1.2kW/575W electronic ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set the beam mechanically and meter centre and edge separately. Choose the ballast mode recommended for the shot and test warm-up, flicker, shutter and frame rate with the actual package. Keep vents clear and let the head cool before handling.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
The exact FilmGear sheet lists 229 mm full and half scrims, a rotating four-leaf door, a filter frame and 7 m or 15 m head leads. Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the separate L01812DS for 1,800 W/1,200 W operation, or the 1,200 W PAR if you need its different beam shaping. Similar lamp wattage or connector appearance does not establish interchangeability.
What People Are Saying
Field Feedback at a Glance
The FilmGear L01200DS model sheet documents these specific capabilities and working limits. They are not independent owner reviews.
What worked
- Narrow daylight spot: at 6 m the 5° setting gives 25,601 lux at centre.
- Broad coverage option: at 6 m the 52° flood spans 5.85 m in FilmGear’s table.
- Two listed electronic ballast families: FilmGear documents the V3 1.8kW/1.2kW/575W and 1.2kW/575W options for the dedicated 1,200 W head.
Drawbacks to plan for
- Do not apply the 3 m figures to a setup: the manufacturer sets a 6 m minimum to illuminated objects.
- The 100 V lamp-circuit rating is not the AC input. Use the selected ballast’s nameplate to plan distribution.
- The 10.7 kg head-and-door package needs rated support before adding cable pull, accessories or retention.
Videos
Use the illustrated FilmGear L01200DS fixture sheet for the exact Fresnel, yoke, door, head cable and lamp options. It identifies this head without relying on footage of the PAR or another fixture from the family.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Confirm head model L01200DS. Match it with MSR 1200HR or HMI 1200W/SE, G38, actual ballast model/input and keyed head cable. Check 28 mm / 1-1/8 in spigot, 175 mm / 6-7/8 in Fresnel, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 6 m illuminated-object clearance and unit-specific manufacturer instructions.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.