Daylight Fresnel 18kW/12kW DE Overview

FilmGear Daylight Fresnel 18k/12k DE lamphead
FilmGear 18 kW/12 kW V3 electronic ballast
18 kW/12 kW ballastExternal dual-wattage ballast specified for this DE Fresnel. Photo: Film Gear USA.
OSRAM 12,000 W HMI DE double-ended 160 V lamp
Double-ended 12 kW lampExample double-ended 12 kW, 160 V HMI lamp. Do not substitute a GX38 single-ended lamp. Photo: Feldmann.

The FilmGear Daylight Fresnel 18k/12k DE (L18012DD) is a dual-wattage HMI head with a 625 mm Fresnel lens. It takes double-ended lamps and weighs 92 kg before doors, cabling or ballast.

The two lamp configurations require the matched 18/12 kW ballast and head cable. The 225 V and 160 V figures apply to the 18 kW and 12 kW lamp circuits, not directly to the mains feed. Use each output table only for its stated wattage.

Detail photo

  • Double-ended HMI Fresnel Ø625 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
  • 18,000 W / 12,000 W lamp + external ballast Lamp circuit: 225 V / 160 V. This is not the ballast mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 92.0 kg lamphead; 98.8 kg with barndoor.
  • Beam Angle Spot 8°; Flood 50°.
  • IP RatingIP20 Lamphead; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Daylight Fresnel 18kW/12kW DE Specifications

SpecificationDetails
Identity numberL18012DD
Capacity18,000 W / 12,000 W
Lamp circuit225 V / 160 V
OpticØ625 mm Fresnel
LampHMI 18000W/DE or HMI 12000W/DE
Colour temperature5600 K
Lamp holderDouble-ended, spring-loaded holder
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP20
Maximum surface temperature230 °C
Maximum ambient temperatureNot stated on the exact-model sheet
Minimum distance to illuminated object15 m
Minimum distance to flammable object2 m
Operating range+30° to -30°
Lamphead weight92.0 kg
Weight with barndoor98.8 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

The calculator uses FilmGear readings from 15 to 35 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The 625 mm Fresnel gives a continuous change in coverage while the head supports either of its specified double-ended lamp configurations. Plan the lamp, ballast and distribution as a package and observe the 15 m illuminated-object clearance.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration15 m25 m35 m
18,000 W · spot 8°43,273 lux15,578 lux7,948 lux
18,000 W · flood 50°5,746 lux2,068 lux1,055 lux
12,000 W · spot 8°36,629 lux13,187 lux6,728 lux
12,000 W · flood 50°3,412 lux1,228 lux627 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Every published centre reading is loaded into the control. Use the table and control only with the stated lamp, optic and test configuration.

Back to contents

Power and Batteries

FilmGear lists 18kW/12kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Compare the dedicated single-ended 12 kW FilmGear Fresnel if your package uses an SE lamp. The 18/12 kW DE head is not that fixture, and the Faceted PAR series uses different optics and data.

What People Are Saying

Videos

No exact operating footage was verified. FilmGear’s Daylight Fresnel 18kW/12kW DE technical sheet is a written source for the model, lamp, optics and matching equipment.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.