Last Updated 2 days ago
FilmGear Daylight Fresnel 200W SE Overview



The FilmGear Daylight Fresnel 200W SE (L00200DS) is a 200 W HMI head with a 112 mm Fresnel. The focus range is 7° to 52° in FilmGear’s catalogue; the head weighs 3.6 kg.
Although the PAR Mini has a similar lens diameter, it uses interchangeable PAR optics rather than this focusable Fresnel. Match the GZY9.5 lamp, ballast and head cable to the Fresnel package.
- Daylight HMI Fresnel Manual-focus daylight Fresnel; Ø112 mm / 4-3/8 in Fresnel; Ø16 mm / 5/8 in socket.
- 200 W lamp + external ballast GZY9.5. Use the matched ballast. 70 V belongs to lamp circuit, not mains.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 3.6 kg lamphead; 4.1 kg with barndoor.
- Beam Angle Spot 7° (2010 catalog); Flood 52° (2010 catalog).
- IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.
FilmGear Daylight Fresnel 200W SE Specifications
| Specification | Details |
|---|---|
| Identity number | L00200DS |
| Capacity | 200 W |
| Lamp circuit | 70 V |
| Optic | Ø112 mm / 4-3/8 in Fresnel |
| Lamp | HMI 200W/SE |
| Colour temperature | 5600 K |
| Lamp holder | GZY9.5 |
| Stirrup | Ø16 mm / 5/8 in socket |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 190 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 2 m |
| Minimum distance to flammable object | 0.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 3.6 kg |
| Weight with barndoor | 4.1 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
Calculator range: 2–8 m (6.6–26.2 ft). The tool estimates only between published measurements. Stay at least 2 m from the illuminated object, or farther if the unit’s instructions require it.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The L00200DS provides adjustable hard daylight from one focusing Fresnel optic. It is small for an HMI, but the 4.1 kg working head, ballast, head cable and 2 m minimum subject clearance still need space.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
The 112 mm focusing Fresnel is not a drop-in PAR lens. Use spot for a daylight hit or flood to cover a larger surface from the same stand position.
Output and Colour
These readings come from the 2010 catalogue for this exact Fresnel, not from a PAR using the same lamp or from a later catalogue edition. Use the beam angle as well as centre lux to plan coverage.
| Optic | 2 m | 5 m | 8 m |
|---|---|---|---|
| Spot 7° | 24,770 lux | 3,963 lux | 1,548 lux |
| Flood 52° | 2,929 lux | 469 lux | 183 lux |
Power and Batteries
FilmGear lists 400W/200W, 400W/200W AC/DC, 200W or 200W AC/DC electronic ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Focus the Fresnel at the head, then check the barn-door cut and beam edge at the subject. The 112 mm Fresnel is a fixed part of the focusing optical system, unlike a removable Mini PAR insert. Check ballast mode and warm-up with the intended shutter and frame rate. FilmGear specifies a maximum surface temperature of 190 °C and 45 °C maximum ambient; leave cooling paths open and allow the head to cool before handling.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the 130 mm Daylight PAR (L00200DP) for interchangeable lens shapes, or the 112 mm Mini PAR (L00200DM) for a smaller lens-based package. This page’s centre-lux figures belong only to L00200DS.
What People Are Saying
These checks come from FilmGear’s current L00200DS specification and the 2010 factory photometric table. They describe documented trade-offs, not independent operator reviews.
- The beam changes without extra lenses At 5 m, the legacy OEM chart gives a 0.61 m spot diameter and 4.88 m flood diameter. The head’s focus handles the change without a lens case.
- The common baby receiver simplifies packing FilmGear specifies a 16 mm receiver and 4.1 kg working head weight with barndoor; pick the stand and safety for the actual build.
- The factory kit covers basic spill control FilmGear lists the four-leaf barndoor plus a 168 mm scrim set in its 200 W Fresnel kit. Verify exactly what the rental supplies.
- Flood is not a substitute for spot intensity At 5 m, FilmGear’s 2010 table gives 3,963 lux spot and 469 lux flood. Meter the working beam instead of relying on the wattage.
- Distance limits can differ across eras Follow the current FilmGear minimum of 2 m to the illuminated object and 0.5 m to flammables, plus any more restrictive marking on the unit.
- Do not confuse it with the 112 mm Mini PAR Although the optics share a nominal diameter and the same lamp class, the Fresnel does not use interchangeable L00200DM lenses or that head’s photometric table.
Videos and Operating Reference
Read the FilmGear 200 W SE Fresnel operating reference. See the exact L00200DS optics, handling limits and compatible factory kit. FilmGear’s 2010 catalogue supplies spot/flood beam diameters and head dimensions; use current clearance guidance rather than its older setback.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Confirm head model L00200DS. Match it with HMI 200W/SE, GZY9.5, actual ballast model/input and keyed head cable. Check 16 mm / 5/8 in socket, 112 mm / 4-3/8 in Fresnel, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 2 m illuminated-object clearance and unit-specific manufacturer instructions.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.