FilmGear Daylight Fresnel 4000W SE

Last Updated 21 hours ago

Overview

FilmGear Daylight Fresnel 4000W SE lamphead
FilmGear V3 4 kW/2.5 kW electronic ballast
4 kW ballast optionExample ballast from the 4 kW-capable FilmGear V3 family. The lamphead itself remains a 4 kW model. Photo: Film Gear USA.
OSRAM HMI DIGITAL 4,000 W single-ended G38 lamp
4 kW G38 lampA 4,000 W single-ended G38 lamp example. Verify your exact rental variant and lamp specification. Photo: LED Centrum.

The FilmGear Daylight Fresnel 4000W SE (L04000DS) is a single-wattage 4 kW HMI Fresnel with a 300 mm lens. FilmGear publishes 6° spot and 64° flood.

This is not the 4k/2.5k dual-wattage head. Match the G38 lamp, the ballast output and head cable, and plan mains using the ballast input rating. FilmGear states a 10 m minimum to illuminated objects.

Detail photo

  • Daylight HMI Fresnel Ø300 mm Fresnel; Ø28 mm / 1-1/8 in spigot.
  • 4,000 W lamp + external ballast G38. 200 V belongs to the lamp circuit, not mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 21.8 kg lamphead; 24.3 kg with barndoor.
  • Beam Angle Spot 6°; Flood 64°.
  • IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

Key specifications

SpecificationDetails
Identity numberL04000DS
Capacity4,000 W
Lamp circuit200 V
OpticØ300 mm Fresnel
LampMSR 4000HR or HMI 4000W/SE
Colour temperature5600 K
Lamp holderG38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature170 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object10 m
Minimum distance to flammable object1.2 m
Operating range+45° to -45°
Lamphead weight21.8 kg
Weight with barndoor24.3 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Photometrics are not safety clearances. FilmGear sets 10 m (32.8 ft) to illuminated objects and 1.2 m (3.9 ft) to flammable objects for the L04000DS. Model-specific datasheet.

Output Calculator

The calculator uses FilmGear readings from 10 to 15 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 10 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The fixed 300 mm Fresnel changes continuously between spot and flood without an external lens set. This is the 4 kW-only Fresnel, not the dual-wattage PAR.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration5 m10 m15 m
Spot 6°75,144 lux18,786 lux8,349 lux
Flood 64°6,961 lux1,740 lux773 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

The table keeps FilmGear’s published test readings. Distances below the stated minimum are reference measurements only and are not available in the calculator.

Back to contents

Power and Batteries

FilmGear lists 4kW/2.5kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

L04025DS is the separate dual-wattage Fresnel, and L04025DP the interchangeable-lens PAR. Neither supplies a substitute chart for the 4 kW-only L04000DS.

What People Are Saying

Practical takeaways from FilmGear’s L04000DS specifications, not independent owner reviews.

What worked

  • The Fresnel’s 6° spot gives 18,786 lux at centre and approximately 1.05 m beam diameter at 10 m.
  • At 64° flood the field is about 12.50 m at 10 m, covering a broad backing from the same head without a lens change.
  • FilmGear lists rotating four-leaf doors and a 394 mm full/half scrim set for spill and output control.

Drawbacks to plan for

  • The 5 m factory rows are reference readings, not operating distances. FilmGear requires 10 m to illuminated surfaces and 1.2 m (3.9 ft) to flammables.
  • The 24.3 kg with-door figure exceeds the 21.8 kg bare head; include fitted hardware and cable loads in support planning.
  • A ballast marked 4 kW/2.5 kW does not make the L04000DS a 2.5 kW head. Verify the 4 kW G38 lamp and matched cable.

Videos

Illustrated fixture reference: FilmGear’s L04000DS drawing and accessory sheet shows the 300 mm Fresnel head, beam spread and accessory package.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.