FilmGear Daylight Fresnel 575W SE

Last Updated 21 hours ago

FilmGear Daylight Fresnel 575W SE Overview

FilmGear Daylight Fresnel 575W SE lamphead
FilmGear V3 1.2 kW/575 W electronic ballast
1.2 kW/575 W ballastExample of the dual-wattage FilmGear ballast family. Confirm the head cable and connector. Photo: Film Gear USA.
OSRAM HMI 575 W/SEL XS G22 lamp
575 W G22 lampExample 575 W single-ended G22 lamp, shown on its own. Photo: B&H.

The FilmGear Daylight Fresnel 575W SE is a 575 W HMI with a 130 mm Fresnel lens. The 2010 catalogue publishes 6° spot and 55° flood for this head, and the current specifications list a bare weight of 6.4 kg.

It takes a 575 W G22 single-ended lamp and a matched external ballast and cable. The 95 V figure applies to the lamp circuit, not the mains. Do not substitute the 575 W PAR’s accessory sizes or output figures.

Detail photo

  • Daylight HMI Fresnel Manual-focus daylight Fresnel; Ø130 mm / 5-1/8 in Fresnel; Ø28 mm / 1-1/8 in spigot.
  • 575 W lamp + external ballast G22. Use the matched ballast. 95 V belongs to lamp circuit, not mains.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 6.4 kg lamphead; 7.0 kg with barndoor.
  • Beam Angle Spot 6° (2010 catalog); Flood 55° (2010 catalog).
  • IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.

Jump to Output Calculator ↓

FilmGear Daylight Fresnel 575W SE Specifications

SpecificationDetails
Identity numberL00575DS
Capacity575 W
Lamp circuit95 V
OpticØ130 mm / 5-1/8 in Fresnel
LampHMI 575W/SE
Colour temperature5600 K
Lamp holderG22
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature160 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object5 m
Minimum distance to flammable object0.5 m
Operating range+45° to -45°
Lamphead weight6.4 kg
Weight with barndoor7.0 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Output Calculator

Calculator range: 5–8 m (16.4–26.2 ft). The tool estimates only between published measurements. Stay at least 5 m from the illuminated object, or farther if the unit’s instructions require it.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The L00575DS gives continuously adjustable hard daylight from a 130 mm Fresnel. It will take barn doors without a separate PAR lens set, but it still requires a ballast, interconnect and enough throw for FilmGear’s current 5 m subject clearance.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

The 130 mm manual-focus Fresnel is not the 575W PAR. Use spot for a defined opening and flood to fill a wider wall; do not substitute the PAR readings.

Output and Colour

These readings come from the 2010 catalogue for this exact Fresnel, not from a PAR using the same lamp or from a later catalogue edition. Use the beam angle as well as centre lux to plan coverage.

Optic2 m5 m8 m
Spot 6°68,806 lux11,009 lux4,300 lux
Flood 55°7,020 lux1,123 lux439 lux
Centre lux from the FilmGear 2010 factory catalogue, p. 04. The 2 m column is archival only; it is below the 5 m operating clearance used here.

Power and Batteries

FilmGear lists 1.8kW/1.2kW/575W, 1.2kW/575W, 800W/575W or 800W/575W AC/DC ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Control, Cooling and Camera Operation

Set the Fresnel focus at the head and check the cut with the barn doors in position. Ballast response and flicker depend on the exact operating mode, frame rate and shutter. Keep cooling paths open; FilmGear specifies a 160 °C maximum surface temperature and 45 °C maximum ambient temperature.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Alternatives and Related Fixtures

Compare the 575 W Daylight PAR (L00575DP) if you need an interchangeable lens set. The lamp wattage alone does not make that unit a valid photometric substitute for this Fresnel.

What People Are Saying

FilmGear’s 2010 exact-model chart and current Fresnel specifications support the working notes below. They are documented trade-offs, not independent crew reviews.

  • A useful change from spot to flood In FilmGear’s 2010 chart at 5 m, the 6° spot gives a 0.52 m beam and the 55° flood a 5.21 m beam, without a spread lens change.
  • A little more control than a bare reflector The Fresnel’s focus mechanism sets spread and the front barndoor trims spill. It is a distinct optical setup from the manufacturer’s 575 W PAR.
  • Several ballast packages were offered FilmGear lists multiple 575 W-capable ballast families, including an AC/DC variant. Confirm the match and supply configuration of the individual ballast.
  • The newer clearance overrides the legacy chart distance Current FilmGear information specifies 5 m minimum to the illuminated object and 0.5 m to flammables. Its 2010 table’s 2 m readings are archival only.
  • Flood trades centre intensity for size The same catalogue lists 11,009 lux spot and 1,123 lux flood at 5 m. The 575 W label alone says little about the working exposure.
  • Battery use is ballast-specific The HMI head has no built-in battery input. Use only a compatible AC/DC ballast and its approved power kit; the 95 V marking is the lamp circuit, not a supply rating.

Videos and Operating Reference

Read FilmGear’s current 575 W Fresnel specifications for placement and the approved lamp. AVisual’s FilmGear daylight Fresnel clip presents the 575, 1,200 and 2,500 W rental range; it is not a standalone L00575DS output test.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Confirm head model L00575DS. Match it with HMI 575W/SE, G22, actual ballast model/input and keyed head cable. Check 28 mm / 1-1/8 in spigot, 130 mm / 5-1/8 in Fresnel, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 5 m illuminated-object clearance and unit-specific manufacturer instructions.

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.