Last Updated 21 hours ago
Overview



The FilmGear Daylight Par 200W Mini (L00200DM) is a 1.4 kg HMI head with interchangeable 112 mm PAR optics. It takes a 200 W GZY9.5 single-ended lamp.
The full-size 200 W PAR uses 130 mm optics and takes different front accessories. Order lenses for the Mini, as well as the matching external ballast and head cable.
- Daylight HMI PAR Interchangeable-lens daylight PAR; Ø112 mm protective and PAR lens; Ø16 mm / 5/8 in socket.
- 200 W lamp + external ballast GZY9.5. Use the matched ballast. 70 V belongs to lamp circuit, not mains.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 1.4 kg lamphead; 1.7 kg with barndoor.
- Beam Angle Spot 9°; Medium flood 10° × 19°; Wide flood 20° × 38°; Super wide flood 36°; Frosted super flood 30°.
- IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.
Key specifications
| Specification | Details |
|---|---|
| Identity number | L00200DM |
| Capacity | 200 W |
| Lamp circuit | 70 V |
| Optic | Ø112 mm protective and PAR lens |
| Lamp | HMI 200W SE |
| Colour temperature | 5600 K |
| Lamp holder | GZY9.5 |
| Stirrup | Ø16 mm / 5/8 in socket |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 170 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 2 m |
| Minimum distance to flammable object | 0.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 1.4 kg |
| Weight with barndoor | 1.7 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Photometrics are not safety clearances. FilmGear specifies 2 m (6.6 ft) to illuminated objects and 0.5 m (1.6 ft) to flammable objects. L00200DM specifications.
Output Calculator
The calculator uses FilmGear’s 2–6 m readings and estimates between those distances only. FilmGear specifies a 2 m minimum distance to illuminated objects.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The 1.4 kg Mini head is especially useful as a lightweight daylight accent, but its 2 m operating clearance still rules out some close placements.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the lens set to trade centre intensity for wider coverage. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Use the 112 mm set on the Mini, not the standard 200W PAR’s 130 mm lenses. The 9° spot makes a narrow hit; choose a wider lens when you need coverage instead of using the spot value for the whole beam.
Output and Colour
FilmGear measured the centre of the beam for each configuration below.
| Configuration | 2 m | 4 m | 6 m |
|---|---|---|---|
| Spot 9° | 41,587 lux | 10,397 lux | 4,621 lux |
| Medium flood 10° × 19° | 17,882 lux | 4,471 lux | 1,987 lux |
| Wide flood 20° × 38° | 7,291 lux | 1,823 lux | 810 lux |
| Super wide flood 36° | 3,881 lux | 970 lux | 431 lux |
| Frosted super flood 30° | 3,105 lux | 776 lux | 345 lux |
Use these centre-beam readings only with the stated lamp, optic and test configuration. They do not describe an average across the beam.
Power and Batteries
FilmGear lists 400W/200W, 400W/200W AC/DC, 200W or 200W AC/DC electronic ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Match the lens to the shot and check the orientation of the 10° × 19° medium asymmetric field on the subject. Test the fitted ballast’s warm-up and flicker at the actual camera settings; FilmGear lists 45°C maximum ambient and ±45° tilt.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Check the last two letters of the nameplate. The L00200DP is the non-Mini 200 W PAR with different 130 mm optics and a different fitted weight. L00200DS Fresnel and L00200BX Boxer data also do not apply.
What People Are Saying
Practical takeaways from FilmGear’s exact L00200DM specifications, not independent owner reviews.
What worked
- At 2 m, the 9° spot gives 41,587 lux in a 0.31 m field, useful when a very small accent needs separation.
- The 36° super-wide field reaches 2.60 m across at 4 m, an option for wider coverage without moving the light farther back.
- At 1.7 kg with doors, the Mini is lighter to place than the separate 3.7 kg Daylight PAR 200W package.
Drawbacks to plan for
- Match the GZY9.5 200 W single-ended HMI, ballast and cable together. A shared 70 V lamp-circuit rating does not make the 400 W Mini lamp interchangeable.
- The 112 mm optics and 127 mm scrims are Mini hardware. Do not order the 130 mm optical set for the non-Mini L00200DP.
- Maintain the 2 m illuminated clearance and 0.5 m to flammables even when the fixture is acting as a small accent.
Videos
Illustrated fixture reference: FilmGear’s L00200DM drawing and accessory sheet shows the head and its model-specific optical and ballast package.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Confirm head model L00200DM. Match it with HMI 200W SE, GZY9.5, actual ballast model/input and keyed head cable. Check 16 mm / 5/8 in socket, 112 mm protective and PAR lens, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 2 m illuminated-object clearance and unit-specific manufacturer instructions.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.