FilmGear Daylight Par 400W Mini

Last Updated 21 hours ago

Overview

FilmGear Daylight Par 400W Mini lamphead
FilmGear 400 W/200 W electronic ballast
400 W/200 W ballastThis FilmGear ballast family serves compatible 200 W and 400 W heads. Confirm the keyed head cable. Photo: Film Gear USA.
OSRAM HMI 400 W/SE single-ended GZZ9.5 lamp
400 W GZZ9.5 lampExample 400 W GZZ9.5 single-ended HMI lamp, not the 200 W Mini’s GZY9.5 lamp. Photo: BulbAmerica.

The FilmGear Daylight Par 400W Mini (L00400DM) is a 400 W HMI head with interchangeable 130 mm lenses. It takes a GZZ9.5 single-ended lamp and weighs 3.0 kg bare.

Do not confuse the optics or lamp with those in the 200 W Mini. Match the external ballast, head cable and lens package to the model number.

Detail photo

  • Daylight HMI PAR Interchangeable-lens daylight PAR; Ø130 mm protective and PAR lens; Ø16 mm / 5/8 in socket.
  • 400 W lamp + external ballast GZZ9.5. Use the matched ballast. 70 V belongs to lamp circuit, not mains.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 3.0 kg lamphead; 3.3 kg with barndoor.
  • Beam Angle Spot 9°; Medium flood 10° × 20°; Wide flood 20° × 42°; Super wide flood 40°; Frosted super flood 34°.
  • IP RatingIP23 Lamphead; not waterproof; ballast/cable rating separate. Read the IP Rating.

Jump to Output Calculator ↓

Key specifications

SpecificationDetails
Identity numberL00400DM
Capacity400 W
Lamp circuit70 V
OpticØ130 mm protective and PAR lens
LampHMI 400W SE
Colour temperature5600 K
Lamp holderGZZ9.5
StirrupØ16 mm / 5/8 in socket
Class / IP ratingClass 1 / IP23
Maximum surface temperature170 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object3 m
Minimum distance to flammable object0.5 m
Operating range+45° to -45°
Lamphead weight3.0 kg
Weight with barndoor3.3 kg
FilmGear primary documentation.

The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.

Photometrics are not safety clearances. FilmGear specifies 3 m (9.8 ft) to illuminated objects and 0.5 m (1.6 ft) to flammable objects. L00400DM specifications.

Output Calculator

The calculator uses FilmGear’s 3–7 m readings and estimates between those distances only. FilmGear specifies a 3 m minimum distance to illuminated objects.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The 400 W Mini combines a 3 kg head with five 130 mm PAR optics. Allow for a separate ballast and the 3 m illuminated-object clearance when comparing its footprint to a panel.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the lens set to trade centre intensity for wider coverage.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

The 400W Mini’s 130 mm lens diameter alone does not establish parts interchange. Compare the medium and wide lens configurations at your working distance and orient the wider axis to suit the setup.

Output and Colour

FilmGear measured the centre of the beam for each configuration below.

Configuration3 m5 m7 m
Spot 9°50,182 lux18,059 lux9,214 lux
Medium flood 10° × 20°20,368 lux7,333 lux3,741 lux
Wide flood 20° × 42°5,710 lux2,056 lux1,049 lux
Super wide flood 40°4,363 lux1,571 lux802 lux
Frosted super flood 34°3,199 lux1,151 lux587 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

Use these centre-beam readings only with the stated lamp, optic and test configuration. They do not describe an average across the beam.

Power and Batteries

FilmGear lists 400W/200W or 400W/200W AC/DC electronic ballast options. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Control, Cooling and Camera Operation

Match the lens to the shot and check the orientation of the 20° × 42° wide asymmetric field on the subject. Test the fitted ballast’s warm-up and flicker at the actual camera settings; FilmGear lists 45°C maximum ambient and ±45° tilt.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Alternatives and Related Fixtures

The L00200DM 200 W Mini has 112 mm optics and a different lamp base. The L00400BX 400 W Boxer is a separate head; use the specific chart, accessories and clearance for the unit booked.

What People Are Saying

Practical takeaways from FilmGear’s exact L00400DM specifications, not independent owner reviews.

What worked

  • At 5 m the 9° spot gives 18,059 lux in a 0.79 m field, a useful reference for a small hard shaft.
  • The 10° × 20° medium flood covers 0.87 × 1.76 m at 5 m for a rectangular opening.
  • FilmGear’s documented kit includes five optics and 168 mm full/half scrims, so coverage changes need not depend on moving the head.

Drawbacks to plan for

  • The 130 mm protective and beam-shaping lenses share a listed diameter but do different jobs; retain the proper protective assembly.
  • Use the specified GZZ9.5 400 W/SE lamp package. The 70 V figure is the lamp circuit, not the ballast mains supply.
  • The 3 m illuminated clearance excludes closer placements, and the external ballast and cable are separate from the 3.3 kg head-with-doors figure.

Videos

Illustrated fixture reference: FilmGear’s L00400DM drawing and accessory sheet shows the head and its model-specific optical and ballast package.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Confirm head model L00400DM. Match it with HMI 400W SE, GZZ9.5, actual ballast model/input and keyed head cable. Check 16 mm / 5/8 in socket, 130 mm protective and PAR lens, safety glass, accessory retention, and then test stable output and flicker at your intended camera settings. Observe 3 m illuminated-object clearance and unit-specific manufacturer instructions.

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.