FilmGear Daylight Par Faceted F1.8k

Last Updated 21 hours ago

FilmGear F1.8k Overview

FilmGear Daylight Par Faceted F1.8k lamphead
FilmGear product photograph reproduced in the Carbone source for model identification.
FilmGear V3 1.8 kW / 1.2 kW / 575 W ballast controls
1.8 kW / 1.2 kW / 575 W ballast controlsThe V3 300 Hz ballast variant is shown; verify the model and connections supplied in the kit. Photo: FilmGear.
Photograph of an OSRAM 1,800 W single-ended G38 HMI lamp
1,800 W G38 lamp class1,800 W / 140 V G38 example shown for base and electrical class, not identified as FilmGear’s photometric test lamp. Verify the required lamp code and arc geometry for the head. Photo: Prophot.

The FilmGear Daylight Par Faceted F1.8k is a 1,800 W open-reflector HMI head with spot-to-flood focus behind a UV protective lens. It uses a separate electronic ballast and matching head cable.

The head uses a 1,800 W single-ended G38 lamp. FilmGear lists the separate V3 1.8 kW / 1.2 kW / 575 W ballast; its other wattage settings are not alternate lamp ratings for this head.

Detail photo

  • Faceted HMI PAR Ø265 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
  • 1,800 W lamp + external ballast G38. 140 V belongs to the lamp circuit, not mains input.
  • Colour Temperature5,600 K Nominal daylight lamp rating.
  • Weight 12.0 kg lamphead; 14.0 kg with barndoor.
  • Beam Angle Spot 17.1°; Flood 73.7°.
  • IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.

Jump to Output Calculator ↓

FilmGear F1.8k Specifications

SpecificationDetails
Identity numberL01800FP (current family listing); L0180FPS on the 2023 sheet
Capacity1,800 W
Lamp circuit140 V
OpticØ265 mm UV protective lens; focusable faceted reflector
LampHMI 1800W/SE
Colour temperature5600 K
Lamp holderG38
StirrupØ28 mm / 1-1/8 in spigot
Class / IP ratingClass 1 / IP23
Maximum surface temperature160 °C
Maximum ambient temperature45 °C
Minimum distance to illuminated object4.5 m
Minimum distance to flammable object1 m
Operating range+45° to -45°
Lamphead weight12.0 kg
Weight with barndoor14.0 kg
FilmGear primary documentation.

FilmGear’s current F-Series family page and an earlier localized sheet identify the head as L01800FP, while the linked 2023 individual sheet prints L0180FPS. The capacity, 140 V lamp circuit, HMI 1800W/SE lamp, G38 holder, optic and measurements agree. The identity suffix remains an explicit manufacturer-source discrepancy.

Output Calculator

The calculator uses FilmGear readings from 6 to 12 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 4.5 m.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

The F1.8k gives a narrow, long-throw beam without a case of spread lenses. The glass is still essential: the 265 mm UV-protective front is part of the head, not a removable beam-shaping option. Allow for a 14 kg head with barndoor plus the separately carried ballast and cable.

Practical Uses

UseWorking approach
Hard daylight punchUse the spot optic for reach, then confirm beam diameter as well as centre level.
Beam shapingUse the focus mechanism to move between the documented spot and flood limits.
Exterior or window workUse the IP rating only with the complete, correctly closed head and protected ballast connections.
Practical applications and limits.

A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.

Back to contents

Output and Colour

FilmGear publishes a complete exact-model measurement table.

Configuration6 m9 m12 m
Spot 17.1°19,000 lux9,000 lux5,000 lux
Flood 73.7°5,000 lux2,600 lux1,500 lux
Complete FilmGear table. Values are centre lux at the stated distance; beam diameters remain in the manufacturer specification.

FilmGear specifies a 4.5 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 6 to 12 m, with interpolation only inside that range. Both FilmGear sheets list these same six readings. The published clearance is a separate safety limit, not a calculator setting.

Back to contents

Power and Batteries

FilmGear lists 1.8kW/1.2kW/575W V3 electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.

The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.

Back to contents

Control, Cooling and Camera Operation

Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use. Keep ventilation unobstructed and allow the head to cool before handling; FilmGear lists a maximum surface temperature of 160 °C.

Modifiers, Rigging and the Working Package

Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.

Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.

Back to contents

Alternatives and Related Fixtures

Use the 1.8 kW/1.2 kW Daylight PAR (L01812DP) if the job needs that fixture’s interchangeable spread lenses. It is a different optical system, so do not use its chart or assume accessory fit. Compare the F800 in FilmGear’s Faceted PAR range when balancing throw, fixture weight and rigging space.

What People Are Saying

One rental house documents an exact F1.8k ballast package; the remaining points come from the model-specific FilmGear sheet, not from independent on-set testing.

  • Beam spread without another lens case On the published sheet, spot gives a 2.57 m beam at 9 m; flood gives a 13.50 m beam at the same throw.
  • Useful spill controls The individual sheet specifies a rotatable four-leaf barndoor and 330 mm scrims, including half scrims for local reduction.
  • A high-speed rental option Southern Lighting Solutions documented fitting its own F1.8k rental kits with a 1,000 Hz electronic ballast. That does not identify every unit’s ballast or guarantee flicker-free capture.
  • Clearance limits a close setup FilmGear specifies at least 4.5 m to the subject and 1 m to flammable objects, within its stated ±45° operating range.
  • The suffix is not consistent The US sheet and family listing say L01800FP; the 2023 factory sheet prints L0180FPS. Verify the rental’s actual plate before selecting parts or a spare.
  • Not a 1.2 kW head The V3 ballast includes 1,200 W and 575 W settings for other compatible heads. This F1.8k is specified for an HMI 1800W/SE G38 lamp.

Videos and Operating Reference

Read the FilmGear F1.8k operating reference. The FilmGear sheet shows the front and side dimensions, the included UV glass and barndoor, the head cable options, and the model’s safe operating limits. FilmGear’s F-Series video and overview cover the family’s focus and ballast controls, not a model-specific test.

Rental and Used-Fixture Checks

Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.

Back to contents

Documentation and Specifications

FilmGear model documentation · FilmGear daylight family.