FilmGear F1.8k Overview



The FilmGear Daylight Par Faceted F1.8k is a 1,800 W open-reflector HMI head with spot-to-flood focus behind a UV protective lens. It uses a separate electronic ballast and matching head cable.
The head uses a 1,800 W single-ended G38 lamp. FilmGear lists the separate V3 1.8 kW / 1.2 kW / 575 W ballast; its other wattage settings are not alternate lamp ratings for this head.
- Faceted HMI PAR Ø265 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
- 1,800 W lamp + external ballast G38. 140 V belongs to the lamp circuit, not mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 12.0 kg lamphead; 14.0 kg with barndoor.
- Beam Angle Spot 17.1°; Flood 73.7°.
- IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.
FilmGear F1.8k Specifications
| Specification | Details |
|---|---|
| Identity number | L01800FP (current family listing); L0180FPS on the 2023 sheet |
| Capacity | 1,800 W |
| Lamp circuit | 140 V |
| Optic | Ø265 mm UV protective lens; focusable faceted reflector |
| Lamp | HMI 1800W/SE |
| Colour temperature | 5600 K |
| Lamp holder | G38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 160 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 4.5 m |
| Minimum distance to flammable object | 1 m |
| Operating range | +45° to -45° |
| Lamphead weight | 12.0 kg |
| Weight with barndoor | 14.0 kg |
FilmGear’s current F-Series family page and an earlier localized sheet identify the head as L01800FP, while the linked 2023 individual sheet prints L0180FPS. The capacity, 140 V lamp circuit, HMI 1800W/SE lamp, G38 holder, optic and measurements agree. The identity suffix remains an explicit manufacturer-source discrepancy.
Output Calculator
The calculator uses FilmGear readings from 6 to 12 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 4.5 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The F1.8k gives a narrow, long-throw beam without a case of spread lenses. The glass is still essential: the 265 mm UV-protective front is part of the head, not a removable beam-shaping option. Allow for a 14 kg head with barndoor plus the separately carried ballast and cable.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 6 m | 9 m | 12 m |
|---|---|---|---|
| Spot 17.1° | 19,000 lux | 9,000 lux | 5,000 lux |
| Flood 73.7° | 5,000 lux | 2,600 lux | 1,500 lux |
FilmGear specifies a 4.5 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 6 to 12 m, with interpolation only inside that range. Both FilmGear sheets list these same six readings. The published clearance is a separate safety limit, not a calculator setting.
Power and Batteries
FilmGear lists 1.8kW/1.2kW/575W V3 electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use. Keep ventilation unobstructed and allow the head to cool before handling; FilmGear lists a maximum surface temperature of 160 °C.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Use the 1.8 kW/1.2 kW Daylight PAR (L01812DP) if the job needs that fixture’s interchangeable spread lenses. It is a different optical system, so do not use its chart or assume accessory fit. Compare the F800 in FilmGear’s Faceted PAR range when balancing throw, fixture weight and rigging space.
What People Are Saying
One rental house documents an exact F1.8k ballast package; the remaining points come from the model-specific FilmGear sheet, not from independent on-set testing.
- Beam spread without another lens case On the published sheet, spot gives a 2.57 m beam at 9 m; flood gives a 13.50 m beam at the same throw.
- Useful spill controls The individual sheet specifies a rotatable four-leaf barndoor and 330 mm scrims, including half scrims for local reduction.
- A high-speed rental option Southern Lighting Solutions documented fitting its own F1.8k rental kits with a 1,000 Hz electronic ballast. That does not identify every unit’s ballast or guarantee flicker-free capture.
- Clearance limits a close setup FilmGear specifies at least 4.5 m to the subject and 1 m to flammable objects, within its stated ±45° operating range.
- The suffix is not consistent The US sheet and family listing say L01800FP; the 2023 factory sheet prints L0180FPS. Verify the rental’s actual plate before selecting parts or a spare.
- Not a 1.2 kW head The V3 ballast includes 1,200 W and 575 W settings for other compatible heads. This F1.8k is specified for an HMI 1800W/SE G38 lamp.
Videos and Operating Reference
Read the FilmGear F1.8k operating reference. The FilmGear sheet shows the front and side dimensions, the included UV glass and barndoor, the head cable options, and the model’s safe operating limits. FilmGear’s F-Series video and overview cover the family’s focus and ballast controls, not a model-specific test.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.