Last Updated 21 hours ago
FilmGear F12k Overview



The FilmGear Daylight Par Faceted F12k is a 12,000 W open-reflector HMI head with spot-to-flood focus behind a Ø500 mm UV protective lens. It requires a separate electronic ballast and matching head cable.
Confirm the F12k head, the 12 kW single-ended GX38 lamp and the appropriate setting on the matching electronic ballast. The ballast nameplate, not lamp voltage, determines mains input.
- Faceted HMI PAR Ø500 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
- 12,000 W lamp + external ballast Lamp circuit: 160 V. This is not the ballast mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 38.0 kg lamphead; 43.0 kg with barndoor.
- Beam Angle Spot 15°; Flood 50°.
- IP RatingIP23 Lamphead; ballast and cable ratings are separate. Read the IP Rating.
FilmGear F12k Specifications
| Specification | Details |
|---|---|
| Identity number | L12000FP |
| Capacity | 12,000 W |
| Lamp circuit | 160 V |
| Optic | Ø500 mm UV protective lens; focusable faceted reflector |
| Lamp | HMI 12000W/SE |
| Colour temperature | 5600 K |
| Lamp holder | GX38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 220 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 15 m |
| Minimum distance to flammable object | 2 m |
| Operating range | +45° to -45° |
| Lamphead weight | 38.0 kg |
| Weight with barndoor | 43.0 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 15 to 30 m for the listed setups. Between published points the result is an estimate; the calculator does not extrapolate. FilmGear specifies a minimum illuminated-object distance of 15 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The F12k is a dedicated 12 kW hard light with a 500 mm UV-protective front. On a distant window or exterior set, it can move from narrow punch to a broader field without a spread-lens case. The head weighs 43 kg with barndoor before adding support, cable and ballast.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 15 m | 20 m | 30 m |
|---|---|---|---|
| Spot 15° | 33,745 lux | 21,660 lux | 9,626 lux |
| Flood 50° | 6,317 lux | 2,243 lux | 996 lux |
FilmGear specifies a 15 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 15 to 30 m, with interpolation only inside that range. The published readings do not follow a single inverse-square curve; values between them are interpolated estimates, not additional manufacturer measurements. No source reading has been corrected.
Power and Batteries
FilmGear lists 18kW/12kW or 12kW/6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set focus in the working position and compare centre and edge illumination on the subject. Check stable output and flicker with the ballast mode, shutter and frame rate you intend to use. The head’s rated maximum surface temperature is 220 °C; do not obstruct ventilation and allow the assembly to cool before moving or handling it.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Compare the dedicated F9k and F18k when choosing a truck package. The F9k has different clearances and a different beam chart. The F18k’s ballast options overlap, but its reflector and readings are not F12k data.
What People Are Saying
The checks below are from the exact FilmGear specification. FilmGear documented a Cine Gear showcase with gaffer Mazi Mitchell, but that is not an independent on-set review.
- A dedicated 12 kW reflector FilmGear’s design note explains why the F12k was split from the F18k: the reflector was optimized for the 12 kW lamp. It is not simply an F18k running at a lower setting.
- Wide adjustment at the head The factory chart gives 5.3 m spot and 18.7 m flood diameters at 20 m, without exchanging spread lenses.
- Two supported ballast families FilmGear’s sheet lists the V3 18/12 kW and 12/6 kW ballasts. Confirm which ballast and head cable are actually in the package.
- Clearance limits indoor positioning FilmGear specifies 15 m to the illuminated object and 2 m to flammables. Those limits apply regardless of whether the chart gives a useful exposure.
- A heavy lift without the ballast FilmGear specifies 38 kg bare and 43 kg with barndoor. Plan the move and support from the working weight, not the bare head.
- Do not project output beyond the chart The three published spot and flood points are not a single exact inverse-square series. The calculator only estimates between 15, 20 and 30 m.
Videos and Operating Reference
Read the FilmGear F12k operating reference. Check the head drawing, spigot, front assembly, clearance and lamp/ballast configuration. FilmGear’s Cine Gear coverage shows the actual F12k with gaffer Mazi Mitchell; the recap covers the show, not a measured F12k walkthrough.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.