Last Updated 21 hours ago
Daylight Faceted PAR F6k Overview



The FilmGear Daylight Par Faceted F6k is a 6,000 W open-reflector HMI head with spot-to-flood focus behind a Ø420 mm UV protective lens. It requires a separate electronic ballast and matching head cable.
The F6k uses the 6,000 W GX38 lamp and the corresponding setting on the listed ballast. The 9 kW rating on the dual-rated ballast does not change the F6k’s lamp rating.
- Faceted HMI PAR Ø420 mm UV protective lens; focusable faceted reflector; Ø28 mm / 1-1/8 in spigot.
- 6,000 W lamp + external ballast GX38. 125 V belongs to the lamp circuit, not mains input.
- Colour Temperature5,600 K Nominal daylight lamp rating.
- Weight 32.0 kg lamphead; 36.0 kg with barndoor.
- Beam Angle Spot 15°; Flood 54°.
- IP RatingIP23 Lamphead; not waterproof; ballast and cable ratings are separate. Read the IP Rating.
Daylight Faceted PAR F6k Specifications
| Specification | Details |
|---|---|
| Identity number | L06000FP |
| Capacity | 6,000 W |
| Lamp circuit | 125 V |
| Optic | Ø420 mm UV protective lens; focusable faceted reflector |
| Lamp | HMI 6000W/SE |
| Colour temperature | 5600 K |
| Lamp holder | GX38 |
| Stirrup | Ø28 mm / 1-1/8 in spigot |
| Class / IP rating | Class 1 / IP23 |
| Maximum surface temperature | 190 °C |
| Maximum ambient temperature | 45 °C |
| Minimum distance to illuminated object | 12 m |
| Minimum distance to flammable object | 1.5 m |
| Operating range | +45° to -45° |
| Lamphead weight | 32.0 kg |
| Weight with barndoor | 36.0 kg |
The FilmGear identity number, lamp type, lamp voltage, optic, mount, IP rating, clearances and weights are preserved exactly from the manufacturer material. Lamp voltage is kept separate from ballast input voltage.
Output Calculator
The calculator uses FilmGear readings from 20 to 30 m for the stated lamp and optic. Between published distances the result is an estimate; no result is given outside this range. The published minimum distance to the illuminated object is 12 m.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
The faceted reflector can change from a tight beam to a wide wash using the focus control. That flexibility does not remove the 12 m minimum throw or the need for a matched 6 kW lamp circuit and rigging.
Practical Uses
| Use | Working approach |
|---|---|
| Hard daylight punch | Use the spot optic for reach, then confirm beam diameter as well as centre level. |
| Beam shaping | Use the focus mechanism to move between the documented spot and flood limits. |
| Exterior or window work | Use the IP rating only with the complete, correctly closed head and protected ballast connections. |
A lamphead wattage is not an input-current specification. Ballast version, mains voltage, power factor and connector determine the supply load.
Output and Colour
FilmGear publishes a complete exact-model measurement table.
| Configuration | 10 m | 20 m | 30 m |
|---|---|---|---|
| Spot 15° | 31,069 lux | 8,630 lux | 3,835 lux |
| Flood 54° | 5,183 lux | 1,926 lux | 576 lux |
FilmGear specifies a 12 m minimum distance to the illuminated object. The calculator is restricted to published measurements from 20 to 30 m, with interpolation only inside that range. Any closer rows in the archival table are reference readings, not permitted working distances. The published readings do not follow a single inverse-square curve; values between them are interpolated estimates, not additional manufacturer measurements. No source reading has been corrected.
Power and Batteries
FilmGear lists 9kW/6kW or 6kW electronic ballast. The head also requires the matching lamphead-to-ballast cable and lamp.
The lamp voltage belongs to the controlled lamp circuit. It is not the mains supply voltage. Use the matched FilmGear ballast, head cable and connectors, then size distribution from the ballast nameplate for the local supply.
Control, Cooling and Camera Operation
Set focus with the head in its working position, then compare centre and edge illumination on the subject. Test warm-up, stable output and flicker with the ballast mode, shutter and frame rate you intend to use.
Modifiers, Rigging and the Working Package
Use the published stirrup mount with a rated stand or clamp and a separate safety cable. Fit only the correct-diameter FilmGear lens, barndoor, scrim or filter accessories.
Keep the published minimum illuminated-object and flammable-object clearances. Inspect the safety glass or lens, yoke, lamp holder, interconnect and accessory retention before energising the head.
Alternatives and Related Fixtures
Choose a separate-lens PAR if distinct lens patterns are important. This F6k uses the faceted reflector and focus mechanism with its specified UV lens; do not substitute output figures or hardware from the F9k or another 6 kW head.
What People Are Saying
Practical takeaways from FilmGear’s exact model documentation, not independent operator reviews.
Strengths
- The factory 15° Spot setting delivers 8,630 lux at 20 m, useful for a concentrated daylight effect from well outside frame.
- The 54° Flood setting provides a wider field without packing a different spread lens; the 420 mm UV protective lens stays in place.
- FilmGear specifies a family of 495 mm full and half scrims plus a spill ring, giving fixture-specific level and spill options.
Limitations
- At 20 m, Flood gives 1,926 lux versus 8,630 lux in Spot. Re-meter after changing focus or adding diffusion.
- The published 10 m row is closer than the 12 m illuminated-object minimum. Do not use it as an operating distance; the existing calculator starts at 20 m.
- The head is listed at 32 kg before doors and uses a 28 mm spigot. Confirm the rated support plus a matched 9/6 kW or 6 kW V3 ballast and head cable.
Videos
No model-specific operating video was verified. Use FilmGear’s F6k data sheet, front accessories and ballast list as a written reference, not footage.
Rental and Used-Fixture Checks
Confirm the identity number on the head, the exact lamp code and base, ballast model, mains input, head-cable connectors, optic set, barndoor and safety wire. Test cold start, warm-up stability, hot restrike and camera flicker behaviour before accepting the package.
Documentation and Specifications
FilmGear model documentation · FilmGear daylight family.
Browse FilmGear · HMI lights · all equipment.