Last Updated 5 days ago
Prolight 1200W Overview



The LTM Prolight 1200 is a 1,200 W daylight Fresnel with a focusing lens and a separate ballast. Its spot-to-flood adjustment suits a controlled hard key, window light or a source directed into bounce or diffusion. It is a different fixture from the Luxarc 1200.
The 2004 B&H catalogue describes a double-ended lamp; LTM’s 2008 2115K page specifies single-ended MSR 1200. This specification table follows the factory version. Inspect the actual lampholder before ordering lamps, accessories or a case.
- TypeSingle-ended HMI Fresnel · Prolight 2115K
- Power1,200 W MSR lamp; separate matched ballast
- Colour Temperature5,600 K nominal
- Weight18.7 lb (8.5 kg) head per LTM drawing
- Beam6–60° with 200 mm Fresnel
- IP RatingNo exact numerical IP rating confirmed. IP rating guide.
Prolight 1200W Specifications
| Manufacturer reference | 2115K |
|---|---|
| Lamp | 1,200 W single-ended MSR; G38; LTM 809025 |
| Optic | 200 mm Fresnel; published focus range 6–60° |
| Control gear | 1,200 W magnetic or 575/1200 W electronic PFC |
| Head Weight | 18.7 lb, as labelled on LTM’s drawing |
| Head Dimensions | 9⅜ in wide × 12¹³⁄₁₆ in high × 9¹³⁄₁₆ in deep; drawing dimensions, not full kit dimensions |
| Head cable | A662, 10 m |
Original LTM PDF with dimensioned head drawing and factory readings
Prolight 1200W Output Calculator
Compare full spot and full flood for the single-ended LTM Prolight 1200W (2115K). Select an LTM distance (10, 20, 30 or 40 ft) or enter a distance from 10 ft to 100 m. Other distances are estimates.
Camera Settings
F-stop is a planning estimate, not a meter reading. It uses the selected published illuminance at the target for a direct, on-axis setup. No added diffusion, bounce, filters, dimming or ambient light is included. Meter the actual setup; lens transmission, camera response and meter calibration can change the working stop.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps) in seconds. The default incident-meter calibration constant is C = 340 (Sekonic Lumisphere reference); C = 250 is available as a flat Lumidisc reference. These are calibration assumptions applied to the selected lux value, not a simulation of a dome’s angular response or a guarantee that every meter will agree. The result is a calculated f-number, not a measured T-stop or an exposure recommendation for every subject. No ND or lens-transmission compensation is applied. The display uses a full-stop mark plus tenths of an exposure stop. For example, f/5.6 followed by a smaller 3 means three tenths of a stop above f/5.6. The display runs from f/0.5 to f/64; a lens may cover a much narrower range. This is still a planning estimate, not a measured T-stop.
The source records foot-candles, converted here at 1 fc = 10.7639 lux. The 2007 LTM data apply to the single-ended 2115K. They are not a prediction for a different head, lamp, intermediate focus, ballast mode or diffusion.
Distance estimates and comparisons
At 10, 20, 30 and 40 ft the values come from the LTM reference. Between those distances an interpolated estimate follows a curve through the nearest reference points. Beyond 40 ft it estimates inverse-square falloff. It does not estimate below 10 ft. Meter the assembled fixture for an actual exposure.
View LTM’s published readings
| Focus | 10 ft | 20 ft | 30 ft | 40 ft |
|---|---|---|---|---|
| Full spot | 13,151 | 3,288 | 1,461 | 822 |
| Full flood | 722 | 180 | 80 | 45 |
Optics and Beam Control
The Fresnel provides a variable spot-to-flood beam without the separate spread-lens set used by a Cinepar. Use barndoors for spill and the matched wire scrims for light reduction. Soft light requires a separate diffusion or bounce setup, with its own output loss.
Strengths and Limitations
The 2115K gives a compact Fresnel field, but the working kit is still a head, ballast, header and lamp.
Practical Uses
| Setup | Working Approach |
|---|---|
| Hard Key or Window Light | Set the Fresnel focus for the required coverage and control spill with the correct barndoors. |
| Bounce or Diffusion | Allow for modifier loss and meter after the bounce or diffusion, not at the bare head. |
Output and Colour
The 2004 B&H catalogue describes a double-ended-lamp version; LTM’s later 2115K page specifies single-ended MSR 1200. Their output tables must not be treated as one version. The French factory table also repeats spot intensities in its flood rows despite different beam dimensions. Use the correctly identified head and meter the assembled setup.
The following readings are from LTM’s original English Prolight 1200W PDF, Ref. 2115K (©2007). They retain the factory distances, beam dimensions and foot-candle units for the single-ended-lamp model.
Spot Reference Readings
| Distance | Beam (ft) | Illuminance (fc) |
|---|---|---|
| 10 ft | 1.0 | 13,151 |
| 20 ft | 1.9 | 3,288 |
| 30 ft | 2.9 | 1,461 |
| 40 ft | 3.9 | 822 |
Flood Reference Readings
| Distance | Beam (ft) | Illuminance (fc) |
|---|---|---|
| 10 ft | 11.5 | 722 |
| 20 ft | 23.1 | 180 |
| 30 ft | 34.6 | 80 |
| 40 ft | 46.2 | 45 |
These are published reference measurements, not a guarantee for every lamp or ballast. Lamp age, operating conditions, focus and modifiers affect the actual result. No readings are inferred between the listed distances.
Power and Batteries
The original LTM 2115K Prolight 1200 page links directly to these factory ballast references: 594004, A893. Match the exact ballast, lamp setting, head feeder and connectors; similarly numbered dealer products are not established equivalents. The linked magnetic A893 is a 230 V, 50 Hz model, not the separate 120 V A608. Use the 1200 W lamp setting and the documented A662 10 m head cable.
Lamp wattage is not mains input power. Confirm the installed ballast’s supply voltage, frequency and current rating, the approved head cable and connector pinout. Do not connect the lamphead directly to the mains or infer compatibility from connector appearance.
Control, Cooling and Camera Operation
Use the head’s focus control to move the short-focus Fresnel from spot to flood; strike it on the matched ballast. The original LTM 2115K documentation specifies the 1200 W setup. Do not follow the dealer page’s stray reference to a 125/200 W selector. Original LTM model and ballast references.
Keep the head and ballast ventilation clear and let the assembly cool before opening it. For critical or high-speed shots, warm up the complete head, lamp and ballast and inspect a recording at your working frame rate and shutter setting; do not assume the electronic and magnetic ballasts behave alike.
Modifiers, Rigging and the Working Package
| Reference | Documented Detail |
|---|---|
| Chimera Speed Ring | 245 mm; Quartz/Daylite 9205 (listed as Pro 1200) |
| Robert Juliat Shutter Adaptation | JAL2/206 P, FPAOA20057; 206 mm beam aperture |
Speed-ring dimensions, wire-scrim sizes and shutter apertures refer to different accessory interfaces; they are not interchangeable lens diameters. Match the actual holder and head version before selecting parts.
Plan support for the full assembled head, lamp, yoke, modifier and cable load. Verify the support fitting and accessory retention on the actual unit. Keep protective glass, lens retention and interlocks intact; have damaged legacy equipment inspected before use.
The manufacturer’s 2115K accessory list identifies these parts. References apply to that documented head; check the actual version before ordering.
| Accessory | LTM Reference | Documented Detail |
|---|---|---|
| Lamp | 809025 | MSR 1200W, G38 |
| Four-Leaf Barndoor / Gel Frame | A 39 / A 90 | Listed for the 2115K head |
| Full Single / Full Double Scrim | M435204 / M435205 | Manufacturer references |
| Half Single / Half Double Scrim | M435206 / M435207 | Manufacturer references |
| Head Cable | A 662 | 10 m |
Alternatives and Related Fixtures
Choose the Prolight 1200W when you need continuous Fresnel focus. Compare the LTM Cinepar 1200W only if you want a PAR and its lens-set workflow; neither its lens readings nor its accessory sizes apply to the Prolight. On a used listing marked Luxarc or 1200W Fresnel, confirm the plate and lamp configuration before treating it as the 2115K single-ended model covered here.
What People Are Saying
B&H’s 2115K product description documents the kit or the fixture’s working characteristics. The points below are practical takeaways from the named equipment sources, not unattributed customer quotes.
Field Feedback at a Glance
- Liked: The short-focus Fresnel changes from spot to flood without a case of separate lenses.
- Liked: Full spot gives substantially greater centre illuminance than full flood at the same distance.
- Liked: The Fresnel takes matching barndoors and wire scrims for practical spill and intensity control.
- Watch for: An older double-ended catalogue description conflicts with later single-ended documentation; match the lamp and socket to the actual head.
- Watch for: The head listing excludes the ballast, lamp and cable. Confirm the complete package when renting or buying.
- Watch for: The fixture’s colour temperature is fixed by the installed lamp; use a suitable CTO or CTB gel for correction when needed and allow for the filter’s light loss.
Videos
No video could be verified for the exact Prolight 1200W 2115K. The original LTM Prolight 1200W technical sheet is a written reference for this head and its optical settings, not footage or a general guide to other LTM fixtures.
Rental and Used-Fixture Checks
| Check | What to Confirm |
|---|---|
| Identity | Match the head model and version, lamp type and selected wattage. Do not substitute a similarly named Luxarc, Cinepar or Prolight. |
| Package | Confirm the correct ballast, head cable, mains cable, barndoors, scrims and any spread lenses or modifier adapters. |
| Condition | Inspect the reflector, protective glass, lens, lamp holder, cable insulation, connectors, yoke and accessory retainers. |
| Camera Test | With qualified crew, test the complete warmed-up system at the intended frame rate and shutter setting. Meter the actual beam and modifiers. |
Documentation and Specifications
LTM original manufacturer model page · French manufacturer edition
B&H Continuous Lighting Catalog · Printed p. 512
Chimera 2013–14 Catalog, pp. 42–43 · Robert Juliat Price List, p. 35
B&H HH-2115K Product Archive · Later Single-Ended Description
Browse LTM Equipment · HMI Lights · All Equipment.