When ordering an HMI package, give the rental house the head model, installed lamp wattage, ballast model including its suffix, and the head feeder you need. Power Gems offers different output sockets on the same ballast model. The EB1812P Gen 2, for example, comes with either two ARRI sockets or one ARRI 18K and one CMC 18K socket. Power Gems permits only one head to be connected at a time, even on a dual-socket ballast.
Safety: This guide identifies equipment; it does not approve a connection or size a circuit. Before use, have the rental house or a qualified lighting electrician confirm the exact head and installed lamp, ballast model and revision, fitted output, approved head cable and total cable length, mains voltage and frequency, and protective earth. Matching wattage, pin count, keying or physical fit does not prove compatibility. Switch off and isolate the ballast from its supply before handling head or power connections. Do not test an unknown combination by plugging it in, modify a cable, bypass a safety interlock or use damaged equipment. ARRI EB MAX 1.8 operating instructions, section 2.
How to Identify an HMI Package
Start with the head if you’re ordering the whole kit. If you’re replacing one part, start with the part number on the original unit. In either case, hand the rental house the IDs below before it substitutes a ballast or feeder.
- Head and lamp: Record the manufacturer, head model and part or Type number. Record the exact lamp code and installed wattage, especially on a dual-wattage head. The ballast’s full wattage range does not add new lamp choices to the head.
- Ballast and outlet: Record the complete part number, revision, input nameplate and fitted lamp-output socket label. Photograph the outside labels with the equipment isolated. If there are two output sockets, identify which one the supplier specifies, not just which one the cable fits.
- Head feeder: Record the manufacturer’s cable part number, both connector ends and the total run needed. A catalogue cable length is what’s sold or included, not necessarily the maximum supported run. The ballast’s mains lead is a different part.
- Confirm the set and the supply separately: Look for an exact OEM kit list, head-to-ballast compatibility table or operating manual. Have the supplier or qualified lighting electrician verify the supplied components and available mains. If labels disagree, parts are modified, or a cross-brand combination is not documented, set it aside until the manufacturer or rental house identifies the exact package. Never plug it in to see whether it works.
A manufacturer’s kit list documents the components sold together. A connector catalogue identifies a shell or insert, not its wiring or an approved lamphead. A lamp data sheet’s control-gear list addresses that specific lamp, not an entire head, cable and ballast package. Historical listings are useful for identification, but a disputed voltage or current stays unresolved until the exact unit and applicable manual are checked.
ARRI HMI Head and Ballast Lookup
Start here if you know the ARRI head. The pairings below are documented factory sets for International (VEAM) heads, not a list of all historical versions or substitutions. Use the ARRI Americas catalogue (2024) and ARRI EMEAI catalogue (2025) to match the regional head and ballast part numbers. The Americas catalogue also covers specified legacy heads, such as Compact 1200 with EB MAX 1.8, in its electronic ballast section.
| Lamphead | Documented ballast choices | VEAM head feeder examples |
|---|---|---|
| M8 | EB MAX 1.8; EB 575/800 HS | L2.75600.0, 7 m |
| M18 | EB MAX 1.8; EB 1200/1800 Basic | L2.75600.0, 7 m |
| M40 | EB MAX 2.5/4; EB 2.5/4 Basic | L2.75620.0, 7 m |
| M90 | EB MAX 6/9; EB 6/9 Basic | L2.77940.A, 15 m |
| ARRIMAX 18/12 | EB MAX 12/18; EB 12/18 Basic | L2.82294.0, 15 m |
| True Blue D5 | EB 575/800 HS; EB 575/1200 Basic | L2.75600.0, 7 m |
| True Blue D12 | EB MAX 1.8; EB 575/1200 Basic | L2.75600.0, 7 m |
| True Blue D25 | EB MAX 2.5/4; EB 2500 Baby; EB 2.5/4 Basic | L2.75620.0, 7 m |
| True Blue D40 | EB MAX 2.5/4; EB 2.5/4 Basic | L2.75620.0, 7 m |
| ARRI Daylight 18/12 | EB 12/18 Basic | L2.82294.0, 15 m |
Don’t buy by connector name alone. For example, ARRI’s Americas M18 cable list includes L2.0005060 (50 ft, rated for 575/800/1200/1800 W) and L2.0005058 (100 ft, rated for 575/1200/1800 W). The M8 list does not identify that 100 ft cable. For regional and legacy versions, check the exact head and ballast in the ARRI discontinued-ballast document library or the regional catalogue rather than treating the VEAM set list as universal.
Power Gems Ballast Ratings
Each model links to its manufacturer specifications. The current column gives the published draw at the named supply voltage. Confirm the fitted output socket and supported lamp power for the individual head. The wattage list describes the ballast family, not every socket. The output label and applicable manual identify which lamp powers the wiring supports. The large-ballast operating guide permits only one connected lamp at a time.
| Ballast and specification | Lamp power options | Input supply | Published input current |
|---|---|---|---|
| EB57P | 200, 400, 575 W | 95–265 V AC | 5.2 A at 120 V |
| EB180P | 575, 800, 1200, 1800 W | 95–265 V AC | 16.7 A at 120 V |
| EB180PD | AC: 200, 400, 575, 800, 1200, 1800 W. Battery: 200–575 W; up to 800 W only under manufacturer-qualified conditions. | 95–265 V AC or 48–60 V DC | 16.7 A at 120 V AC |
| EB425P | 1.2, 1.8, 2.5, 4 kW | 95–265 V AC | 37.5 A at 120 V |
| EB960P | 2.5, 4, 6, 9 kW | 190–265 V AC | 42 A at 230 V |
| EB1812P Gen 2, dual ARRI | 6, 9, 12, 18 kW | 195–265 V AC | 81.7 A at 230 V |
| EB1812P Gen 2, ARRI and CMC | 6, 9, 12, 18 kW | 195–265 V AC | 81.7 A at 230 V |
| EB241812P | 12, 18, 24 kW | 195–265 V AC | 112 A at 230 V |
For a 200 W or 400 W head, check the full ballast model and fitted output. The current EB180PD specification lists those powers, while the current EB180P product table starts at 575 W. Power Gems also described a dual-output EB180P capable of driving six fixture types in 2014, without listing six distinct wattages. A six-item description alone therefore does not identify an older unit as EB180PD.
The EB180PD manufacturer sheet limits battery operation to 200–575 W, with 800 W possible only in some circumstances. AC mains operation supports the higher ratings through 1800 W. Do not interpret the combined output list as an 1800 W battery rating.
The EB85P / EB125P / EB180P Rev D operating guide specifies 100–265 V AC for EB180P, whereas its current product table lists 95–265 V AC. Match the individual nameplate and applicable manual. The guide permits only one connected lamp at a time and states that supported lamp powers depend on the fitted socket wiring.
ARRI Head-to-Ballast Feeder Cables
These are selected ARRI International (VEAM) cable part numbers and supplied lengths, not maximum total cable runs. Check the specified total length for the head, ballast revision and available supply. ARRI separately lists Schaltbau EVENT 1200/1800 W cables L2.75600.F (7 m) and L2.75600.E (15 m). They are not alternatives for an International (VEAM) connection.
| ARRI cable | Length | Listed head examples |
|---|---|---|
| L2.75600.0 | 7 m | M8, M18, True Blue D5 and D12 |
| L2.75620.0 | 7 m | M40, True Blue D25 and D40 |
| L2.77940.0 | 7 m | M90 |
| L2.82294.0 | 15 m | ARRIMAX 18/12 and ARRI Daylight 18/12 |
ARRI cable ordering table · Power Gems output socket options
For example, ARRI specifies cable-loss compensation on suitable heads with the EB MAX 1.8 up to 50 m at 120 V for US model L2.0014189, up to 80 m at 120 V for L2.0014190, and up to 100 m at 230 V. These are model- and supply-specific compensation limits, not a general allowance to extend any HMI head cable. ARRI EB MAX 1.8 technical sheet.
Identifying a Head Connector
Read the insert arrangement, key position and connector manufacturer before ordering a feeder. Two seven-contact connectors can have different key positions. Link’s LKH catalogue lists 24-2W for the ARRI 575 W and 1200 W heads, and 24-2 for ARRI 2.5 and 4 kW. At 6 kW it lists 28-22 for ARRI. At 12 and 18 kW it lists 28A-9 for ARRI and 28-10 for Sunray. These identify connector arrangements only, not wiring, ignition, interlock compatibility or approved pairings. Confirm the head, ballast and feeder with the manufacturer or rental house.
Illustrated LKH insert arrangements and manufacturer cross-reference
ARRI Electronic Ballasts
Use the part number on the ballast to select the rating. For example, the Basic 12/18 and MAX 12/18 both run 12 kW and 18 kW lamps, but ARRI gives them different maximum line power. Volt-amperes (VA) describe apparent power drawn from the supply. Lamp power is given in watts.
Basic and Lightweight Ballasts
| Ballast and part | Lamp power | Supply | Maximum line power | Head examples |
|---|---|---|---|---|
| EB 575/1200 (Basic) L2.76425.0 | 575 / 1,200 W | 90–130 or 180–250 V | 1,350 VA | True Blue D5 and D12 |
| EB 1200/1800 (Basic) L2.76625.0 | 1,200 / 1,800 W | 90–130 or 180–250 V | 2,600 VA | M18 and True Blue D12 |
| EB 2500 Baby (Basic) L2.76695.0 | 2,500 W | 180–250 V | 2,800 VA | True Blue D25 and Compact 2500/Theater |
| EB 2.5/4 (Basic) L2.76640.0 | 2,500 / 4,000 W | 230 V nominal | 4,650 VA | M40 and True Blue D25/D40 |
| EB 6/9 (Basic) L2.76180.0 | 6,000 / 9,000 W | 180–250 V | 11,200 VA | M90 and ARRI Daylight 6000 |
| EB 12/18 (Basic) L2.76290.0 | 12 / 18 kW | 190–250 V | 19,400 VA | ARRIMAX 18/12 and ARRI Daylight 18/12 |
| EB 125/200 L2.76013.A / .B | 125 / 200 W | 90–130 or 180–250 V | 240 VA | Pocket PAR 125 or 200, matched to the head cable |
| EB 400/575 L2.76260.0 / L2.76262.0 | 400 / 575 W | 90–130 or 180–250 V | 667 VA | Pocket PAR 400 or a 575 W ARRI head with the correct connector |
| EB 575/800 High Speed L2.0001687 | 575 / 800 W | 90–130 or 180–250 V | 1,160 VA | M8 and True Blue D5 |
ARRI lists a second EB 575/1200, the ETL L2.0000355, at 1,390 VA. Its 2.5/4 family also includes a Schaltbau version, L2.76677.0. The Basic 1200/1800 has 1,200 and 1,800 W output settings. For the 800 W M8, ARRI documents the EB 575/800 High Speed and the EB MAX 1.8.
EB MAX Ballasts

| Ballast and part | Lamp power | Supply | Maximum line power | Head examples |
|---|---|---|---|---|
| EB MAX 1.8 L2.0014189 (USA) | 575 / 800 / 1,200 / 1,800 W | 90–130 or 180–250 V | 2,600 VA | M8, M18 and True Blue D5/D12 |
| EB MAX 2.5/4 L2.0019423 (USA) | 2,500 / 4,000 W | 100–130 or 180–250 V | 5,400 VA | M40 and True Blue D25/D40 |
| EB MAX 6/9 L2.0019425 (USA) | 6,000 / 9,000 W | 180–250 V | 11,200 VA | M90 and ARRI Compact 6000 |
| EB MAX 12/18 L2.0019426 (USA) | 12 / 18 kW | 190–250 V | 19,600 VA | ARRIMAX 18/12 and ARRI Daylight 18/12 |
The EB MAX 6/9 requires 180–250 V at the mains. Its 6 kW and 9 kW settings select lamp power. ARRI EB MAX 6/9 operator manual
ARRI Magnetic Ballasts
These specifications belong to the North American catalogue numbers shown. The frequency rating changes with the model. Check the nameplate when identifying an older rental unit.
| Lamp | Catalogue no. | Input voltage and frequency | Nominal input current | Weight |
|---|---|---|---|---|
| 575 W | 505805 | 108–132 V, 60 Hz | 7.5 A at 120 V | 32 lb |
| 1,200 W | 512805 | 108–132 V, 60 Hz | 14 A at 120 V | 48 lb |
| 2,500 W | 525805 | 108–132 V, 60 Hz | 25 A at 120 V | 80 lb |
| 4,000 W | 540805 | 108–132 or 198–240 V, 60 Hz | 42 A at 120 V or 22 A at 220 V | 144 lb |
| 6,000 W | 560805 | 198–242 V, 50/60 Hz | 34 A at 220 V | 132 lb |
| 12,000 W | 562805 | 200–250 V, 60 Hz | 62 A at 240 V | 199 lb |
ARRI historical lighting catalogue, magnetic ballasts (printed pages 20–21)
Identifying Historical ARRI Connector Variants
ARRI’s March 2007 spare-parts sheets distinguish the Compact and BCA/BU ballast families below. The sheets do not cross-reference the six-digit North American catalogue numbers in the preceding table. Use these part numbers to identify a matching family and connector variant, not to assume that every ballast of the same wattage has the same socket.
| Ballast Family | Connector Listed by ARRI | Part Number |
|---|---|---|
| Compact 575 W | Schaltbau / VEAM alternatives | L4.75950.E / L4.75952.E |
| Compact 1200 W | Schaltbau / VEAM alternatives | L4.75970.E / L4.75960.E |
| Compact 2500 W | Schaltbau / VEAM alternatives | L4.75951.E / L4.75953.E |
| BCA 4000-3 / A / E | Female output connector | L4.75746.E |
| BCA 6000 | Female output connector | L4.75748.E |
| BU12 AR / HR | Female output connector | L4.75786.E |
The Compact sheet separately lists thermal cut-outs for 575 W (L4.75758.E), 1200 W (L4.75763.E) and 2500 W (L4.75768.E). It distinguishes European timer fuse cover L4.75769.E from USA cover L4.75770.E; the timing-module spare fuse L4.75772.E is expressly labeled European version, without a current rating. These are distinct components, not one universal mains-fuse specification.
The BCA/BU sheet lists 2 AT spare fuses (L4.75732.E) and 6.3 AT spare fuses (L4.75733.E) for BCA 4000/6000, as well as separate magnetothermal protection devices. It distinguishes BCA 4000-3 at 380 V, BCA 4000 A at 110/220 V and BCA 4000 E at 220/240 V. These service-part listings do not establish which fuse position or connector is fitted to a particular North American catalogue number. Match the exact unit and applicable service documentation before selecting replacement parts.
ARRI Compact 575/1200/2500 spare-parts sheet, L5.75750.0, March 2007 · ARRI BCA 4000/6000 and BU12 spare-parts sheet, L5.75720.0, March 2007 · ARRI spare-parts document directory
Mole-Richardson Electronic Ballasts
Match the Type number, lamp setting and fitted connectors on the individual ballast. The figures below are historical entries from Mole-Richardson’s 2008 ballast catalogue (archived PDF; may be unavailable). The manufacturer’s kit brochure confirms some original package combinations, not the electrical or physical specifications in the table. Use the table to identify equipment. For operating limits and power distribution, a qualified lighting electrician should verify the actual nameplate and applicable manual.
| Type | Lamp Setting | Manufacturer Specifications | Connector or Package Evidence | Source Differences and Limits |
|---|---|---|---|---|
| 82833 | 200 W AC square-wave | Operating input range not confirmed; see source differences. Published figures: 50/60 Hz; 5 A maximum; 5 A fuse; ON/OFF rocker; 5 ft attached input cable; 5 lb. | Exact Mole Type 8483 kit records identify Type 82833 as the AC ballast. | Mole’s historical catalogue and DigiMole 8281 sheet give 90–230 V AC; the AV-iQ Type 82833 listing gives 90–260 V AC. Do not use either range to select a supply. Match the individual unit’s nameplate and applicable manufacturer documentation before use. Do not substitute the DC Type 82850 supply rating. |
| 82850 | 200 W DC square-wave | 24–32 V DC; 11 A maximum; internal 15 A fuse; inline ON/OFF rocker; 4 ft attached input cable; 3 lb. | DC input model. Do not substitute the AC Type 82833 record. | This is the DC model, not a 90–260 V AC ballast. |
| 82926 | 400 W AC square-wave | 90–260 V AC, 50/60 Hz; 7.5 A maximum; 10 A fuse; 5 ft attached input cable; 8 lb. | Exact Mole Type 84921 kit records pair the ballast with the 400 W head. | The catalogue specifies the full 90–260 V AC range; connector matching still depends on the actual package. |
| 64970 | 575 W AC | 90–260 V AC, 50/60 Hz; 8.2 A maximum; 10 A fuse; 5 ft attached input cable; 4 lb. Mole’s Type 662101 kit record identifies a 120/240 V package. | Paired with Type 6621 in the documented kit. | The standalone catalogue specifies 90–260 V AC; the kit’s 120/240 V description is not the complete input range. |
| 68220 | 800 W AC | Catalogue text: 90–220 V AC, 50/60 Hz; 9.1 A maximum; 15 A fuse; 5 ft attached input cable; 6 lb. | Exact Type 682101 kit record identifies a 120/240 V package. | The same manufacturer page shows a front-panel label reading 90–130 V AC / 190–260 V AC, AUTO SENSE, rather than the body text’s 90–220 V range. Check the individual ballast nameplate. |
| 63765 | 575 / 1,200 W AC | Catalogue text: 90–230 V AC, 50/60 Hz; 15 A maximum; double-pole breaker and red indicator; 6 ft attached input cable; 17 lb. | Exact-model Mole data verifies the two lamp settings. | The same manufacturer page pictures a 95–260 V AC, 15 A maximum front-panel label, differing from its 90–230 V body text. A surviving 1.2/1.8K kit listing does not establish an 1,800 W setting for this 575/1,200 W model. Check the actual nameplate. |
| 638185 | 2,500 / 4,000 W AC | 95–260 V AC, 50/60 Hz; 33.6 A maximum; double-pole breaker and red indicator; attached input cable; 31 lb. | Documented for Mole 2.5K/4K HMI heads with the matching connector. | The manufacturer range starts at 95 V, not 90 V. Cable length is printed as “X ft.” and is not specified numerically. |
| 66569 | 4,000 / 6,000 W AC | 195–260 V AC, 50/60 Hz; 65 A maximum; circuit breaker; 5 ft detachable Veam-type input cable with customer-specified connector; 95 lb. | Exact Mole package evidence identifies a 195–260 V 6K kit using a Power Gems 4/6K ballast. | The catalogue specifies 195–260 V, not 90–260 V. Its cable designation “665XX” is a placeholder, not an established orderable part number. The separate exact-model record describes a double-pole breaker and red indicator; this catalogue says only “circuit breaker.” |
| 66065 | 12 / 18 kW AC | 208–240 V AC, 50/60 Hz; setting-specific mains current not established here; double-pole breaker and red indicator; Type 66066 5 ft detachable input cable with Veam-type/customer-specified connector; 140 lb. Mole’s Type 6791 sheet also identifies this 12K/18K ballast. | Type 680192 is the documented 50 ft head cable for Type 6791. | The historical catalogue prints 80 A maximum without a voltage- and lamp-setting-specific current table. Do not use that figure to plan supply. Type 66066 is the input cable, distinct from the Type 680192 head cable. |
| 680229 | 12 / 18 / 24 kW AC | 208–240 V AC, 50/60 Hz; setting-specific mains current not established here; double-pole breaker and red indicator; Type 66066 5 ft detachable input cable with Veam-type/customer-specified connector; cart; 140 lb. | Mole’s Type 6861 sheet verifies this ballast with the 24K Fresnel and Type 680192 head cable. | The historical catalogue prints 80 A maximum even though it lists 24 kW capability. It does not establish setting-specific mains current and must not be used to size the supply. The shared 680192 cable part number does not establish interchangeability with the other ballast or head. Check the actual unit’s nameplate and applicable manual; Type 66066 is the input cable, not the Type 680192 head cable. |
Mole’s Type 6801 Daylite Fresnel sheet also identifies 680192 as its 50 ft head cable. That confirms a cable reference for 6801, not the ballast for every 6801 package. Mole names specific ballasts for the Type 6791 PAR and Type 6861 24K Fresnel in the linked factory sheets above.
Catalogue Dimensions
| Type | Listed Size |
|---|---|
| 82833 | 10 × 6.25 × 3 |
| 82850 | 7 × 4.25 × 3 |
| 82926 | 11 × 7.5 × 6.25 |
| 64970 | 8.25 × 4.25 × 7.5 |
| 68220 | 9 × 8.5 × 5 |
| 63765 | 11.5 × 9 × 7 |
| 638185 | 15 × 10.5 × 9.5 |
| 66569 | 22 × 20.5 × 27; 48.5 high with handle raised |
| 66065 | 30 × 20.5 × 27; 48.5 high with handle raised |
| 680229 | 30 × 20.5 × 27; 48.5 high with handle raised |
The catalogue does not label the three dimension axes; their printed order is retained. Large HMI distribution must be planned from the individual ballast nameplate and applicable manual. Lamphead voltage and current belong to the lamp circuit after the ballast, not the mains input.
K5600 HMI Ballasts and Mixed-System Power Supplies
The Lexicon groups five K5600 boxes under HMI ballasts, but the 300 W and 1200 W rows also name K5600 LED product families. Those two rows remain PSU identifications until an exact part number and nameplate establish the output type. Do not connect a lamphead from a nominal wattage alone.
| Source row | Verified function | Input evidence | Compatibility and Identification Limits |
|---|---|---|---|
| 300 W PSU | Mixed-system power supply, not verified as an HMI ballast | Lexicon prints 120 V AC only. | K5600’s product catalogue classifies Joker 300 and Alpha 300 as LED and lists Slice 300 LED. Exact PSU part number, output voltage and connector are required before any compatibility claim. |
| 400 W HMI ballast | Electronic flicker-free 400 W Joker ballast | K5600’s system catalogue specifies 90–265 V AC for its dedicated electronic ballasts and identifies a 400 W ballast in the Joker-Bug 400 kit. | Use with the matching Joker 400 generation, head cable and connector. The Lexicon’s 120 V statement is an operating example, not the full input range. |
| 800 W HMI ballast | Electronic square-wave Joker² 800 ballast, B0800E2 on the Joker² kit | 90–265 V AC, 50/60 Hz; 7.5 A at 120 V; 1000 Hz high-speed mode and wireless DMX on the manufacturer product listing. | Joker² specifications do not automatically describe every original Joker-Bug 800 ballast. Confirm the actual generation and nameplate. |
| 1200 W “ballast” | Mixed-system power supply, not verified as an HMI ballast | Lexicon prints 120 V AC only. | K5600’s product catalogue lists Slice 1200 as LED and no 1200 W Joker or Alpha HMI lamp class. Exact PSU part number, output and connector remain unresolved. |
| 1600 W HMI ballast | Electronic square-wave ballast for Joker 1600 and Alpha 1600 | Alpha 1600 kit documentation: 90–265 V AC, 50/60 Hz, 15 A at 120 V, 1000 Hz high speed. Legacy catalogue: 16 A at 110 V or 7.4 A at 230 V. | The HMI package is verified. Any claimed use with Slice LED still requires the exact supply part and output connector. |
K5600 lists U0800B2 with B0800E2 in the Joker² 800 kit, along with a 25 ft C0900U head extension. The original Joker-Bug 800 factory page instead describes its own 25 ft shielded extension without identifying the Joker² part number. Its separate Alpha 1600 kit lists UALPHA1600 with B1600E and the 25 ft C1600U extension. These records identify the factory packages, not a maximum head cable run. They don’t establish backward compatibility with an original Joker-Bug or show that an LED supply can drive an HMI head.
K5600 Joker² 800 specifications · K5600 Alpha 1600 specifications · K5600 legacy system catalogue · K5600 lamp-family directory
Altman IREM Magnetic Ballasts
IREM confirms that its magnetic ballast and hot-restrike ignitor range covers metal-halide lamps from 200 W through 18,000 W, including film and television lighting. The historical Altman rows below do not include an exact IREM model number or nameplate photograph. Their printed input values are therefore preserved as source claims, not as distribution instructions.
| Source row | Lexicon claim | Primary-source finding | Identification Limits |
|---|---|---|---|
| 200 W magnetic | 120 V AC, 5 A maximum; fuse; 7.5 lb | IREM confirms a 200 W lower end for its metal-halide ballast range. | Exact Altman/IREM model, input frequency, fuse and weight still need an original plate or factory sheet. |
| 575 W magnetic | 120 V AC, 7 A maximum; fuse; 32 lb; 208 V version noted | IREM’s current primary material does not identify the historical Altman model or corroborate its printed input ratings. | Open until the exact model number, frequency, connector and nameplate are recovered. |
| 1,200 W Magnetic / Altman 1200MB | Lexicon: 120 V AC, 13.5 A maximum; fuse; 47 lb; 208 V version noted. | Altman’s ©2003 1200SE sheet identifies 1200MB and specifies 120 V / 60 Hz at 14 A maximum, or 220 V / 50 Hz and 240 V / 50 Hz at 7 A maximum. It describes a recessed bipolar main breaker, VEAM head connection and 6 ft 14/3 SJT power cord, with an Edison plug on the standard 120 V / 60 Hz version. The magnetic ballast adds approximately 47 lb. | The factory sheet’s 14 A and breaker description differ from the Lexicon’s 13.5 A and fuse. Its stated 50 Hz alternatives do not verify the separate 208 V variant. The underlying IREM model is not identified; match the actual Altman unit’s nameplate rather than transferring these specifications to every 1,200 W ballast. |
| 575 / 1,200 W magnetic | 120 V AC, 13.5 A maximum; fuse; 47 lb | A dual setting requires the exact switchgear, ignitor and connector record. Nominal wattages alone do not establish compatibility. | Open pending exact Altman and IREM model numbers. |
| 2,500 W magnetic | 120 V AC, 25 A maximum; fuse; 79 lb; 208 V version noted | IREM’s BC family covers this lamp class. The printed input claim is not corroborated by an exact factory sheet. | Open pending model, frequency, fuse, connector and nameplate. |
| 4,000 W magnetic | 120 V AC, 40 A maximum; fuse; 132 lb; 208 V version noted | OSRAM’s HMI 4000 W/SE factory sheet names IREM BC-4000 as compatible control gear. | The OSRAM lamp-to-control-gear listing is verified; it does not identify or approve the complete Altman package. The Altman enclosure’s exact line input, fuse, weight and connector remain open. |
| 2,500 / 4,000 W magnetic | 120 V AC, 40 A maximum; fuse; 132 lb | A dual-wattage claim needs an exact selector and ignitor record. IREM’s current overview does not identify this historical Altman box. | Open. Verify both supported lamp settings from the plate before connection. |
| 6,000 W magnetic | 120 V AC, 40 A maximum; fuse; 132 lb | 120 V × 40 A is 4.8 kVA before ballast losses, below a 6 kW lamp load. | The printed 120 V / 40 A combination is rejected as a usable mains specification. Exact model and higher-voltage input evidence are required. |
| 18,000 W magnetic | 120 V AC, 92 A maximum; fuse; 330 lb | IREM confirms the BC-18K model family. However, 120 V × 92 A is 11.04 kVA before losses, below an 18 kW lamp load. | BC-18K existence is verified; the Lexicon’s 120 V / 92 A combination is rejected. Use the exact factory sheet and nameplate. |
IREM metal-halide ballast and ignitor range · IREM BC-18K overview · OSRAM HMI 4000 W/SE control-gear list
For every historical magnetic ballast, record the input voltage and frequency, lamp setting, protection, output connector, ignitor, permitted head cable and protective-earth condition from the individual unit. A source-row wattage label is not a compatibility test.
LTM Legacy HMI Ballasts
LTM’s archived manufacturer range separates battery-powered electronic, mains electronic and magnetic ballasts. The references below are the factory numbers shown in those original pages, recovered from the manufacturer’s archived website. They must not be substituted for an older dealer part number solely because the wattage is similar.
| Factory Reference | Lamp Settings and Type | Published Input Supply | Published Weight |
|---|---|---|---|
| 597001 | 125 / 200 W electronic DC | 24–35 V DC | 2.2 lb |
| 594002A | 125 / 200 W electronic AC | 90–130 or 190–260 V AC, 50/60 Hz | 4.41 lb |
| 597003 | 200 / 400 / 575 W electronic PFC | 90–260 V AC, 50/60 Hz | 6.61 lb |
| 594004 | 575 / 1,200 W electronic PFC | 90–260 V AC, 50/60 Hz | 19.84 lb |
| 598007 | 2.5 / 4 kW electronic PFC | 190–260 V AC, 50/60 Hz | 41.89 lb |
| 598009 | 4 / 6 kW electronic PFC | 190–260 V AC, 50/60 Hz | 66.14 lb |
| 598010C | 6 / 12 kW electronic PFC, with cart | 190–260 V AC, 50/60 Hz | 110.23 lb |
| 598020C | 6 / 12 / 18 kW electronic PFC, with cart | 190–260 V AC, 50/60 Hz | 110.23 lb |
| A 821 | 200 W magnetic | 120 V, 60 Hz | 19.84 lb |
| A 124 | 575 W magnetic | 120 V, 60 Hz | 37.48 lb |
| A 608 | 1,200 W magnetic | 120 V, 60 Hz | 59.52 lb |
| A 323 | 2,500 W magnetic | 120 V, 60 Hz | 88.18 lb |
| A 429 | 4,000 W magnetic | 120 V, 60 Hz | 187.39 lb |
| A 435 | 6,000 W magnetic | 205 / 215 / 230 / 245 V, 60 Hz | 198.42 lb |
| A 807 | 200 W magnetic | 230 V, 50 Hz | 15.43 lb |
| A 345 | 575 W magnetic | 230 V, 50 Hz | 22.05 lb |
| A 893 | 1,200 W magnetic | 230 V, 50 Hz | 39.68 lb |
| A 320 | 2,500 W magnetic | 230 V, 50 Hz | 88.18 lb |
| A 428 | 4,000 W magnetic | 230 V, 50 Hz | 187.39 lb |
| A 442 | 6,000 W magnetic | 230 V, 50 Hz | 198.42 lb |
| 592020 | 12 / 18 kW magnetic | 240 V, 50 Hz | 302.03 lb |
Combination Settings and Model Generations
Factory reference 597003 explicitly supports 200, 400 and 575 W. Factory reference 598020C explicitly supports 6, 12 and 18 kW. These combinations are documented LTM products. The older B&H SourceBook’s HB593003, HB593009 and HB593010 listings describe differently numbered products, so their narrower settings do not disprove the later factory combinations. The recovered factory range does not establish a three-wattage 200/400/575 W magnetic model.
For the small battery system, the factory identifies 597001 as 24–35 V DC and 594002A as a separate mains AC unit. The older dealer catalogue instead lists HB593000 and HB593002A. Their equivalence is not established here; the older HA7004FC battery package is not automatically a match for the later factory reference.
Where Historical Listings Differ
The B&H SourceBook LTM listings and the archived factory pages give different values for several similarly named magnetic ballasts. For example, the factory A 608 page gives 16 A at 120 V and 59.52 lb, while the dealer’s HBA6081200 entry gives 12.5 A and 55 lb. The factory A 323 page gives 24 A at 120 V and 88.18 lb, compared with 26 A and 122 lb in the dealer’s HBA3232500 entry. These are source and edition differences, not proof that every surviving unit has the newer rating.
The factory A 429 page identifies a 120 V, 60 Hz magnetic ballast, with 43 A at 120 V and a published weight of 187.39 lb. The dealer HBA429 entry mixes a different input range and frequency with 42 A at 120 V and 202 lb. Those mixed dealer fields should not be used to specify the factory A 429. The factory A 435 is a multi-tap 60 Hz model with 32 A stated at 230 V, rather than the dealer’s 50 A at 220 V; these are different test voltages as well as different records.
598020C Input Ratings and Documented Head Pairing
The 598020C factory page lists input current at 230 V as 27.5 A at 6 kW, 57 A at 12 kW and 87 A at 18 kW. Its 100 A circuit breaker is a separate protection rating, not the operating draw. Published dimensions are 22⅞ in wide × 20½ in high × 11⅞ in deep; the page does not specify whether those dimensions include the cart.
The 287V Luxarc 12/18 kW Superlight head page links directly to 598020C and the 592020 magnetic ballast. This establishes those factory-listed pairings for 287V, not interchangeability with other similarly named heads. The head supports 12 kW or 18 kW lamps; the ballast’s separate 6 kW capability does not add a 6 kW configuration to this head.
Using the Factory Records
Read the actual ballast nameplate and match the head, lamp setting, feeder and connector before planning a package. The table identifies documented models; it is not a cross-manufacturer compatibility list or a substitute for the individual unit’s electrical ratings. A circuit-breaker rating is not an operating-current specification.
Even the factory pages contain inconsistencies: the DC 597001 record includes an inapplicable 50/60 Hz field, and the 592020 magnetic record gives an 18 kW input-current figure that leaves no allowance for ballast losses. Those fields are not adopted here. Weight conditions are stated explicitly only where the factory title identifies the cart.