Quasar Science Rainbow 2 Q25R2

Last Updated 5 hours ago

Overview

Q25R2 product views

The Q25R2 is the two-foot Rainbow 2. Its ten pixels give moving colour and highlights in a head short enough to conceal beside a window, inside scenery or along a small product table.

The nominal two-foot body is 23 inches long. It takes external DC or AC power, so leave room for the cable when hiding it in the set.

  • Fixture TypeQ25R2 · nominal 2 ft Rainbow 2 with 10 pixels in one row
  • Power25 W maximum; AC or external DC
  • Colour Temperature1,750–10,000 K RGBX Spectral Science
  • Weight and Mount0.8 kg fixture; Ossium rail
  • Beam Control180° diffused stock lens
  • IP RatingIP40 No rated water protection; keep dry · IP Ratings Guide

Jump to Output Calculator ↓

Key specifications

SpecificationDetails
Manufacturer and ModelQuasar Science Rainbow 2 Q25R2
Maximum Rated Power25 W
Pixels10, single row
Dimensions23 × 1.75 in. / 584.2 × 44.45 mm
Weight1.76 lb / 0.8 kg
CCT Range1,750–10,000 K
AC Current0.25 A at 120 V; 0.13 A at 240 V
DC Current2.50 A at 12 V; 1.30 A at 24 V
DataBuilt-in Ethernet node; wired DMX, sACN and Art-Net; wireless CRMX, W-DMX, Bluetooth, sACN and Art-Net as listed in the series brochure
MountingOssium rail, slider and baby pin

Photometric Output Calculator

Estimate centre-beam illumination and the corresponding camera aperture from this fixture’s published measurements.

Estimated output

Illuminance—lux
Foot-candles—fc
Estimated f-stop—Full stop + tenths of a stop

Select a configuration to calculate.

Manufacturer readings are for the stated optic, colour setting and full output, measured at the beam centre. Values between measured distances are interpolated. Point-source values outside those distances are approximate inverse-square estimates; large sources cannot be reliably extrapolated and are limited to their measured range. Exposure uses frame rate, shutter angle, ISO and the selected incident-meter calibration. Only the optics and diffusion explicitly listed in the measurement are included; additional modifiers, bounce, beam edges, ambient light, ND filters and camera exposure-index differences are not accounted for. Confirm critical exposures on set with a meter.

Strengths and limitations

  • Ten pixels are enough for a short travelling reflection in a small practical.
  • The short emitting length may reveal pixel steps in very close reflections.

Working with the Rainbow 2 Q25R2

Run a slow chase along the tube beside a reflective object. Test the pixel resolution in the reflection, where individual segments can be much more obvious than on a matte wall.

Output and photometrics

Quasar Science publishes seven CCT readings for this model in its 3 m chart, including the separately labeled 6,279 K point. The chart identifies incident illuminance and distance, but does not state dimmer setting, spectral-control setting, accessory configuration or test power supply. These readings do not establish output for other settings.

CCTDistanceFactory LuxCalculated Foot-Candles
1,750 K3 m28.12.61
2,000 K3 m30.22.81
3,200 K3 m34.73.22
4,300 K3 m37.73.50
5,600 K3 m40.73.78
6,279 K3 m423.90
10,000 K3 m38.33.56

Original manufacturer 3 m photometric chart. The control retains the published 3 m distance only; no distance curve or intermediate CCT reading is inferred from this single-distance chart.

CCTFactory DistanceFactory Foot-Candles
1,750 K10 ft2.7
2,000 K10 ft2.89
3,200 K10 ft3.32
4,300 K10 ft3.62
5,600 K10 ft3.9
6,279 K10 ft4.03
10,000 K10 ft3.67
Separate manufacturer 10 ft chart. These are the source’s printed readings, not conversions of its 3 m values. The two charts use different distances and are not combined into a distance curve.

On-set check

Compare the 3 m chart only with readings taken under a matching setup. For a reflection or close practical, bring the tube to the real working distance and meter there; the calculator deliberately does not infer a curve from a single distance.

Power and controls

The two-foot head accepts direct AC and has both 12 V and 24 V DC figures in the data sheet. Choose the console mode according to the number of pixels needed.

Control on set

Use a grouped mode for one smooth chase or a single-colour cue; reserve the full 10-pixel mode for separate zones. The Quasar firmware guide documents 1, 2, 5 and 10 groups for the Q25R2 on firmware 0.8B; match the console profile to the actual rental firmware.

Optics and mounting

Ossium mounting hardware provides an alternative to gripping the emitting tube. Check the visible end and data direction before programming a chase.

Fit and setup

Turn the fixture through its full intended swivel with the actual cables connected. If the tube will show in frame, decide which end can stay hidden before locking the mount.

Comparable fixture

For the four-foot, 24-pixel tube, see Quasar Science Rainbow 2 Q50R2.

For a two-foot tube with a built-in battery, compare the amaran PT2c. Its mounts and power system are different.

What People Are Saying

Field Feedback at a Glance

What worked

Drawbacks to plan for

  • There’s no internal battery. That can slow down quick repositioning compared with a cordless tube. Graham Sheldon, CineD.
  • Sheldon found the Double Rainbow’s controls easier to work with than the Rainbow 2’s smaller interface. Graham Sheldon, CineD.
  • White balance can vary from the display setting. Naso’s two-foot sample read 8,781 K when set to 10,000 K. Erik Naso, Newsshooter.

Erik Naso, Newsshooter

Naso tested the two-foot Rainbow 2, measuring 309 lux at 3,200 K and 366 lux at 5,600 K at 1 m. He found the Ossium rail made mounting less dependent on improvised tube clamps.

CineD, Rainbow 2 hands-on tests

CineD measured 5,478 K with the two-foot tube set to 5,600 K at full output and measured from 3 ft with no accessory. The reading describes that test setup, not a correction to the manufacturer data.

Field coverage and further reading

Video

Quasar Science Rainbow 2 Review: Pushing LED technology forward!

Rental and used-fixture checks

Verify the R2 suffix and the console pixel mode. The manufacturer lists direct AC plus 12 V and 24 V DC operation for this size.

Before you book

Check for the R2 suffix, Ossium hardware and the correct AC or external DC cables. Before the tube goes out of reach, test which end maps to the first pixel in your console profile.

Documentation

Quasar’s individual 2 ft Rainbow 2 stock-lens and enclosure specifications.

Back to contents · Browse all lighting equipment