Last Updated 21 hours ago
ARRI Compact 12000 Baby Overview



The ARRI Compact 12000 Baby is a 12 kW single-ended HMI Fresnel. ARRI’s reference lists a 500 mm lens and a 6°–51° focus range. The head alone is about 49 kg, without the ballast, cable or doors.
It takes an approved 12 kW lamp, a separate matched ballast and the correct head cable. The factory technical table gives a 15 m minimum to illuminated surfaces for this head, and gives conflicting flammable-object distances. For prep, apply the stricter 15 m heat/UV warning, not the shorter table entry.
- Fixture Type 500 mm HMI Fresnel
- Power 12,000 W G38 fast-lock plus matched ballast
- Colour Temperature 6,000 K nominal daylight class
- Weight 49 kg head; ballast and accessories separate
- Beam Angle 6°–51° published focus
- IP Rating IP23 Check the exact head and connected package. Read the IP Rating Guide.
Compact 12000 Baby Specifications
| Specification | Details |
|---|---|
| Model / ordering reference | L0.75790.B / head type L1.7579x.x |
| Lamp / base | HMI 12000 W/SE / G38 fast-lock |
| Nominal lamp circuit | 160 V; ballast mains input is separate |
| Nominal colour | 6,000 K daylight class in the period ARRI brochure |
| Optic | 500 mm Fresnel lens |
| Published focus range | 6° to 51° |
| Dimensions (H × W × L) | 768 × 884 × 813 mm |
| Head weight | 49 kg |
| Mount | 28 mm junior spigot |
| Documented ballast families | EB 12/18 kW, period EB 6/12 kW, or compatible 12 kW choke ballast as a complete documented package |
| Protection | Class I / IP23 |
| Safety distances / tilt | The manual’s technical table lists 2 m to flammable objects, 15 m to illuminated surfaces and ±75° tilt, but its following warning gives 15 m to flammable objects. See the clearance conflict below; the 2 m table entry is not a confirmed operating clearance. |
| Status | Discontinued |
The Lexicon divides lamp wattage by a convenient supply voltage. That is not the lamp circuit and does not establish ballast input current. Plan distribution from the actual ballast nameplate and manual.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
| Strengths | Limitations |
|---|---|
| Focusable, even daylight field; complete manufacturer spot, middle and flood data; conventional accessories and serviceable construction. | Separate ballast and high-voltage head cable; hot single-ended discharge lamp; dated connector variants; discontinued head and accessory system. |
Practical Uses
| Setup | Working approach |
|---|---|
| Hard daylight key | Select focus for the required pool, then meter the subject rather than relying on centre output alone. |
| Window or exterior fill | Use spot or middle when throw matters and control spill with the retained barndoor. |
| Bounce or diffusion | Use flood to cover the modifier evenly, then meter after transmission or reflection loss. |
The front and rear focus controls move the source through the Fresnel system. Do not use the lens door, accessory latch or cable as a handling point.
Output and Colour
The period ARRI Daylight Compact brochure publishes all nine measurements for this exact 12,000 W head. ARRI states that the data follow ESTA practice and are normalised to nominal lamp lumens.
| Distance | Spot 6° | Middle 30° | Flood 51° |
|---|---|---|---|
| 15 m | 39,333 lux / 1.6 m | 4,711 lux / 8 m | 2,373 lux / 14.3 m |
| 20 m | 22,125 lux / 2.1 m | 2,650 lux / 10.7 m | 1,335 lux / 19.1 m |
| 25 m | 14,160 lux / 2.6 m | 1,696 lux / 13.4 m | 854 lux / 23.8 m |
Distance Limits: the ARRI Compact 12000 operating manual supplied in its Baby archive specifies 15 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 15–25 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use.
The historical table retains all nine documented centre readings; the calculator uses only the readings within the distance limits above. Beam diameter is shown for coverage planning and does not change the exposure calculation.
Power and Batteries
This head uses EB 12/18 kW, period EB 6/12 kW, or compatible 12 kW choke ballast as a complete documented package. Confirm lamp wattage, lamp base, ballast setting, head connector and cable as one package. The 160 V figure describes the lamp circuit, not the supply outlet.
The HMI ballast and head-cable reference separates ARRI electronic and magnetic variants. Use the selected ballast input range, rated current, power factor, frequency mode and protective-device instructions for distribution.
Control, Cooling and Camera Operation
The head has mechanical front and rear focus knobs, an hour counter and a safety switch. The ballast, not the Fresnel head, sets any electronic dimming or frequency mode. ARRI ballast compatibility table lists the EB 12/18 family for this lamp class; match the exact ballast and head connector.
Check for flicker with the actual shutter and frame rate after the lamp stabilises. Listen for ballast and lamp noise from the intended microphone position, and leave the vents clear at the working tilt.
Modifiers, Rigging and the Working Package
The manual’s technical table lists 2 m to flammable objects, 15 m to illuminated surfaces and ±75° tilt, but its following warning gives 15 m to flammable objects. See the clearance conflict below; the 2 m table entry is not a confirmed operating clearance. Operate only with an intact Fresnel, reflector, wire guard or safety glass, lens-door latch and interlock. Keep ventilation open and cables away from the housing.
Manufacturer Clearance Conflict: The 16 June 2004 Compact 12000 manual for head type L1.7579x.x, technical table (PDF page 5) distinguishes 2 m to flammable objects from 15 m to illuminated areas. Its following heat/UV warning (PDF page 6) instead states 15 m to flammable objects; the eye/skin warning also differs between German (10 m) and English (15 m). These are conflicting statements in the same manufacturer document, not interchangeable distance ratings. Do not use the smaller figures to justify a closer setup. Keep at least the larger stated 15 m separation while obtaining the applicable instructions for the exact head and configuration, and follow any stricter requirement. The calculator’s 15–25 m interval is a photometric-data limit, not confirmation that a particular setup is safe.
Support the head, barndoor, filter frame, cable pull and modifier as one load. Use properly rated primary support and secondary retention. A cracked lens, dull reflector, brittle internal lamp lead, heat-damaged connector or unreliable latch removes the head from service.
Alternatives and Related Fixtures
| Fixture | Why compare it |
|---|---|
| ARRI True Blue D5 | A later 575 W daylight Fresnel with current family documentation. |
| ARRI M8 | A lensless 800 W MAX-reflector head for greater throw and a different beam character. |
| ARRI Compact family | Compare the surrounding wattages, lens sizes, support loads and ballast packages. |
What People Are Saying
Field Feedback at a Glance
These are setup findings from ARRI operating manual and ARRI ballast compatibility table, not independent owner reviews.
What works
- The 500 mm Fresnel gives the single-ended 12 kW head a focusable beam; use the front or rear knob depending on access. ARRI operating manual.
- A movable stirrup and adjustable centre of mass help balance approved front accessories on a large head. ARRI operating manual.
- The separate lamp support and locking lever retain the lamp mechanically in addition to its electrical contacts. ARRI operating manual.
Drawbacks to plan for
- The 49 kg bare head requires support and handling sized for the full package. It is not the Daylight 18/12 head even when their ballast family overlaps. ARRI operating manual; ARRI ballast compatibility table.
- ARRI’s manual gives conflicting flammable-object clearances. Follow the more restrictive warning pending confirmation for the exact head; do not plan from the 2 m entry alone. ARRI operating manual.
- The 160 V lamp circuit is not an input rating. A connector-matched ballast configured for the 12 kW lamp is essential. ARRI ballast compatibility table.
Videos and Operating Reference
Use the illustrated ARRI Compact 12000 Baby instructions to find the focus controls, lens-door release and safety attachment. For power and camera checks, follow the instructions for the actual ballast. Do not substitute a Daylight 18/12 or ARRIMAX setup guide.
Rental and Used-Fixture Checks
Read the nameplate before accepting the package. Record the exact head variant, lamp, ballast model, connector and cable. Inspect lamp contacts, lens, reflector, focus travel, interlock, yoke, mount and accessory retention, then test cold start, stable output, hot restrike and the intended camera mode.
Documentation and Specifications
Official ARRI Compact archive · ARRI Daylight Compact brochure · ARRI operating instructions · ARRI Compact certification.
Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.
Browse ARRI lights · HMI lights · all equipment.