Last Updated 22 hours ago
Pocket PAR 125 Overview



The original 125 W Pocket PAR puts a focusable daylight source in a head small enough to position close to props and vehicle interiors. Its optical-tube and projector accessories are central to its usefulness.
The 125 uses the smaller 78 mm optics and its own lamp. Check the lens tray, head lead and ballast as a kit rather than assuming the 200 W versions interchange.
- Type Compact HMI PAR
- Power 125 W GZX9.5 lamp; separate matched ballast
- Colour Temperature Daylight HMI; depends on installed lamp and operating condition.
- Weight 1.1 kg / 2.5 lb head
- Beam Control 78 mm lens system; period chart 5° SuperSpot to 49° SuperFlood
- IP Rating IP20 Indoor dry use; the ARRI certificate identifies the 125 W models. Read the IP rating guide.
Pocket PAR 125 Specifications
| Specification | Details |
|---|---|
| Manufacturer and model | ARRI ARRILUX Pocket PAR 125 |
| Source or rated power | 125 W single-ended HMI PAR |
| Optics, colour or format | 78 mm lens system |
| Head or system detail | 1.1 kg / 2.5 lb head (ARRI dimensional drawing) |
| Lamp base and rating | GZX9.5, 125 W single-ended HMI |
| Four-leaf barn doors | Ø 92 mm front attachment, L2.73380.0 |
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
- The light guide can put daylight into a small cavity while the head remains outside.
- The guide, coupler and projector are specialist accessories that may be missing from a used kit.
Practical Uses
For an instrument panel, a light guide can deliver the light where the head will not fit. For a small shaft behind a subject, use the bare head and its matched spot optics.
Output and Colour
ARRI’s chart fixes the centre reading at 1,000 lux and gives the throw for each lens. These are optimum-focus settings from the April 2000 ARRI sheet, not the whole focusing range. The calculator uses the metric 1,000-lux chart only; the separate feet chart is at 100 fc (about 1,076 lux), not the same intensity. Each configuration has one published anchor, so all other distances are inverse-square estimates, not additional manufacturer measurements. Refocusing or adding modifiers changes output.
| Configuration | Distance | Lux | Foot-candles |
|---|---|---|---|
| Superspot 5° | 17 m | 1,000 | 92.9 |
| Narrow flood 8° | 13 m | 1,000 | 92.9 |
| Flood 21.5° | 6 m | 1,000 | 92.9 |
| Superflood 49° | 3 m | 1,000 | 92.9 |
| Frosted Fresnel 42° | 2.3 m | 1,000 | 92.9 |
Photometric source and test conditions.
Power and Batteries
The 125 W head uses the 7 m Binder cable L2.73382.0. ARRI’s original system brochure lists the L2.76012.0 mains ballast and the L2.76040.B 125/200 W battery ballast. The separate DC converter is an accessory for the battery setup.
Control, Cooling and Camera Operation
Use the rated 125 W lamp and the corresponding Pocket PAR ballast. Confirm the individual bayonet lens locks before planning a framing or beam change.
Modifiers, Rigging and the Working Package
The dedicated projector and liquid light guide give this head uses beyond conventional PAR work. A gel frame and spread lenses serve different purposes.
The original ARRI system brochure identifies the Narrow Flood converter L2.73402.0 (10–20°), Flood L2.73404.0 (20–45°), Super Wide L2.73462.0 (50–70°) and Frosted Fresnel L2.73464.0. These focusing ranges differ from the optimum-focus chart settings above.
For Liquid Light, ARRI lists an 8 mm collector L2.79188.0, 1.5 m tube L2.79189.0, 3 m tube L2.79197.0 and front optic L2.79198.0. The brochure gives the zoom-output example as 21,000 lux over a 185 mm circle to 15,000 lux over a 255 mm circle at 1 m; this accessory example is not a bare-PAR calculator configuration. It also lists the M-size gobo holder L2.79283.0 and four projector focal lengths: 75, 100, 150 and 200 mm.
Alternatives and Related Fixtures
For another small focusable discharge head, see Dedolight DLH200DT.
What People Are Saying
The model-specific points below come from ARRI’s documents, with handling or rental examples identified separately. They are not a survey of owner reviews.
Field Feedback at a Glance
What worked
- A small daylight head for a tight spot. The 1.1 kg head is easier to position in a confined set than a larger HMI. The LA Firm demonstrates the exact 125 W Pocket PAR, not a Pocket Lite. View exact-model reference.
- Lens choices change spread without changing the lamp. ARRI documents narrow, flood, super-wide and frosted options in the 78 mm system. ARRI Pocket PAR 125 documentation.
- Optional projection optics for a small target. The original 125 brochure lists dedicated gobo projectors. That makes it possible to choose a defined pattern or edge instead of simply widening the PAR beam. ARRI Pocket PAR 125 documentation.
Drawbacks to plan for
- The 80 V/1.6 A rating is for the head. It is not a mains or battery requirement. ARRI lists separate 125 W AC and compatible 125/200 W DC ballast options; confirm the exact kit. ARRI range certificate.
- The standard 125 is IP20. The ARRI certificate identifies the 125 W models as IP20, so don’t borrow an IP23 rating from some 200 W or 400 W versions. ARRI range certificate.
- Check the small head’s dedicated accessories. The 77–78 mm optics, Ø 92 mm barndoor mount and 125 W lamp are not the larger heads’ accessory and lamp system. Identify the ballast and any optical adapter before checkout. ARRI Pocket PAR 125 documentation.
Videos
The LA Firm’s Pocket PAR 125 walkthrough shows the original 125 W light rather than the 200 W or 400 W versions.
Rental and Used-Fixture Checks
Identify the 125 W head and the required adapter before ordering a light guide. Check whether the kit includes an AC ballast or the separate DC system.