Last Updated 21 hours ago
ARRI Compact 4000 Overview



The ARRI Compact 4000 is a single-ended 4 kW daylight HMI Fresnel with a 300 mm lens and a published 7°–65° focus range. The standard head weighs about 21.5 kg before the ballast and cabling.
The Compact 4000 is not the Compact 4000 Theater or a D40. Specify the G38 lamp, compatible 4 kW ballast and matched cable when arranging a kit; plan the mains supply from the ballast nameplate.
- Fixture Type 300 mm HMI Fresnel
- Power 4,000 W G38 plus matched ballast
- Colour Temperature 6,000 K nominal daylight class
- Weight 21.5 kg in 2013 instructions; 21.6 kg in earlier brochure
- Beam Angle 7°–65° published focus
- IP Rating IP23 Check the exact head and connected package. Read the IP Rating Guide.
Compact 4000 Specifications
| Specification | Details |
|---|---|
| Model / ordering reference | L0.74000.B manual / L0.74000.I pole-operated |
| Lamp / base | HMI 4000 W/SE / G38 |
| Nominal lamp circuit | 200 V; ballast mains input is separate |
| Nominal colour | 6,000 K daylight class in the period ARRI brochure |
| Optic | 300 mm Fresnel lens |
| Published focus range | 7° to 65° |
| Dimensions (H × W × L) | 543 × 577 × 456 mm |
| Head weight | 21.6 kg in the 2005 brochure; 21.5 kg in the 2013 instructions |
| Mount | 28 mm junior spigot |
| Documented ballast families | EB 2.5/4 kW or compatible period 4 kW conventional ballast at its documented input supply |
| Protection | Class I / IP23 |
| Safety distances / tilt | 1 m to flammable objects, 10 m to illuminated surfaces and ±90° tilt in the 2013 instructions. |
| Status | Discontinued |
The Lexicon divides lamp wattage by a convenient supply voltage. That is not the lamp circuit and does not establish ballast input current. Plan distribution from the actual ballast nameplate and manual.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
| Strengths | Limitations |
|---|---|
| Focusable, even daylight field; complete manufacturer spot, middle and flood data; conventional accessories and serviceable construction. | Separate ballast and high-voltage head cable; hot single-ended discharge lamp; dated connector variants; discontinued head and accessory system. |
Practical Uses
| Setup | Working approach |
|---|---|
| Hard daylight key | Select focus for the required pool, then meter the subject rather than relying on centre output alone. |
| Window or exterior fill | Use spot or middle when throw matters and control spill with the retained barndoor. |
| Bounce or diffusion | Use flood to cover the modifier evenly, then meter after transmission or reflection loss. |
The front and rear focus controls move the source through the Fresnel system. Do not use the lens door, accessory latch or cable as a handling point.
Output and Colour
The period ARRI Daylight Compact brochure publishes all nine measurements for this exact 4,000 W head. ARRI states that the data follow ESTA practice and are normalised to nominal lamp lumens.
| Distance | Spot 7° | Middle 30° | Flood 65° |
|---|---|---|---|
| 9 m | 22,963 lux / 1.1 m | 5,463 lux / 4.8 m | 2,127 lux / 11.5 m |
| 13.5 m | 10,206 lux / 1.7 m | 2,428 lux / 7.2 m | 975 lux / 17.2 m |
| 18 m | 5,741 lux / 2.2 m | 1,366 lux / 9.6 m | 532 lux / 22.9 m |
Distance Limits: ARRI’s November 2013 Compact operating instructions specifies 10 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 13.5–18 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use. The historical 9 m table reading is retained above for source reference only, not as an operating-distance recommendation, and excluded from the calculator.
The historical table retains all nine readings as printed; the calculator uses the six readings at the retained distances. The 4 kW flood value at 13.5 m is retained as ARRI printed it even though it is slightly above an inverse-square interpolation from the other two distances.
Power and Batteries
This head uses EB 2.5/4 kW or compatible period 4 kW conventional ballast at its documented input supply. Confirm lamp wattage, lamp base, ballast setting, head connector and cable as one package. The 200 V figure describes the lamp circuit, not the supply outlet.
The HMI ballast and head-cable reference separates ARRI electronic and magnetic variants. Use the selected ballast input range, rated current, power factor, frequency mode and protective-device instructions for distribution.
Control, Cooling and Camera Operation
The head has mechanical front and rear focus knobs. The ballast, not the Fresnel head, sets any electronic dimming or frequency mode. ARRI ballast compatibility table lists the EB 2.5/4 family for this lamp class; match the exact ballast and head connector.
Check for flicker with the actual shutter and frame rate after the lamp stabilises. Listen for ballast and lamp noise from the intended microphone position, and leave the vents clear at the working tilt.
Modifiers, Rigging and the Working Package
ARRI documents 1 m to flammable objects, 10 m to illuminated surfaces and ±90° tilt in the 2013 instructions. Operate only with an intact Fresnel, reflector, wire guard or safety glass, lens-door latch and interlock. Keep ventilation open and cables away from the housing.
Support the head, barndoor, filter frame, cable pull and modifier as one load. Use properly rated primary support and secondary retention. A cracked lens, dull reflector, brittle internal lamp lead, heat-damaged connector or unreliable latch removes the head from service.
Alternatives and Related Fixtures
| Fixture | Why compare it |
|---|---|
| ARRI True Blue D5 | A later 575 W daylight Fresnel with current family documentation. |
| ARRI M8 | A lensless 800 W MAX-reflector head for greater throw and a different beam character. |
| ARRI Compact family | Compare the surrounding wattages, lens sizes, support loads and ballast packages. |
What People Are Saying
Field Feedback at a Glance
These are setup findings from ARRI operating manual and ARRI ballast compatibility table, not independent owner reviews.
What works
- Front and rear focus controls let you adjust the Fresnel beam from the reachable side of the head. ARRI operating manual.
- The spring-loaded top latch lets crew fit approved front accessories without refocusing the lamp. ARRI operating manual.
- The Compact series provides a movable stirrup attachment for balancing accessory loads; set it for the package actually being rigged. ARRI operating manual.
Drawbacks to plan for
- The 2013 standard Compact instructions specify 10 m to illuminated surfaces and 1 m to flammables. The historical photometric row at 9 m is not an operating recommendation. ARRI operating manual.
- The 21.5 kg standard head weight does not include doors, ballast or heavy head cable. The 4000 Theater’s larger lens and different weight do not apply. ARRI operating manual.
- A 4 kW G38 lamp rating does not identify the supply or connector. Use a matched EB 2.5/4 or approved period package. ARRI ballast compatibility table.
Videos and Operating Reference
Use the illustrated ARRI Compact 4000 instructions to find the focus controls, lens-door release and safety attachment. For power and camera checks, follow the instructions for the actual ballast. Do not substitute a Compact Theater or True Blue setup guide.
Rental and Used-Fixture Checks
Read the nameplate before accepting the package. Record the exact head variant, lamp, ballast model, connector and cable. Inspect lamp contacts, lens, reflector, focus travel, interlock, yoke, mount and accessory retention, then test cold start, stable output, hot restrike and the intended camera mode.
Documentation and Specifications
Official ARRI Compact archive · ARRI Daylight Compact brochure · ARRI operating instructions · ARRI Compact certification.
Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.
Browse ARRI lights · HMI lights · all equipment.