ARRI Compact 575

Last Updated 21 hours ago

Compact 575 Overview

ARRI Compact 575 daylight Fresnel fixture
Used ARRI Compact 575 kit with head, ballast and accessories
Used kitA Compact 575 with a ballast and front accessories. Used packages vary; verify what is included.
ARRI EB 575/1200 electronic ballast
EB 575/1200 ballastOne period ballast family ARRI documented for the Compact 575. Photo: Light Equip.

The ARRI Compact 575 is a 575 W daylight HMI Fresnel with a 130 mm lens and a published 7°–50° focus range. It uses a G22 single-ended lamp.

The head weighs roughly 7.5 kg before doors, cable or ballast. It is not the ARRISUN 5 PAR or the ARRI D5. Order an approved 575 W ballast and the cable that fits the particular generation of head.

Detail photo

  • Fixture Type Compact daylight Fresnel
  • Power 575 W G22 HMI + compatible ballast
  • Colour Temperature 6,000 K Nominal daylight lamp class; actual CCT depends on the lamp and its condition.
  • Weight 7.5 kg in 2013 instructions; 7.25 kg in 2005 brochure
  • Beam Angle 7° to 50° published focus; 130 mm Fresnel
  • IP Rating IP23 Check the actual head and complete connected system; not waterproof. Read the IP Rating Guide.

Jump to Output Calculator ↓

Compact 575 Specifications

SpecificationDetails
Model / ordering referenceL0.73770.SB / L0.73775.B manual versions
Lamp / baseHMI 575 W/SE / G22
Nominal lamp circuit95 V; ballast mains input is separate
Nominal colour6,000 K daylight class in the period ARRI brochure
Optic130 mm Fresnel lens
Published focus range7° to 50°
Dimensions (H × W × L)314 × 290 × 272 mm
Head weight7.25 kg in the 2005 brochure; 7.5 kg in the 2013 instructions
Mount28 mm junior spigot
Documented ballast familiesEB 400/575, EB 575/1200, EBB 575/1200 battery, or compatible period choke ballast
ProtectionClass I / IP23
Safety distances / tilt0.5 m to flammable objects, 5 m to illuminated surfaces and ±90° tilt in the 2013 instructions.
StatusDiscontinued
ARRI Daylight Compact brochure, 02/2005 · ARRI operating instructions · ARRI Compact certification.

The Lexicon divides lamp wattage by a convenient supply voltage. That is not the lamp circuit and does not establish ballast input current. Plan distribution from the actual ballast nameplate and manual.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

StrengthsLimitations
Focusable, even daylight field; complete manufacturer spot, middle and flood data; conventional accessories and serviceable construction.Separate ballast and high-voltage head cable; hot single-ended discharge lamp; dated connector variants; discontinued head and accessory system.
Working characteristics

Back to contents

Practical Uses

SetupWorking approach
Hard daylight keySelect focus for the required pool, then meter the subject rather than relying on centre output alone.
Window or exterior fillUse spot or middle when throw matters and control spill with the retained barndoor.
Bounce or diffusionUse flood to cover the modifier evenly, then meter after transmission or reflection loss.
Lighting applications

The front and rear focus controls move the source through the Fresnel system. Do not use the lens door, accessory latch or cable as a handling point.

Back to contents

Output and Colour

The period ARRI Daylight Compact brochure publishes all nine measurements for this exact 575 W head. ARRI states that the data follow ESTA practice and are normalised to nominal lamp lumens.

DistanceSpot 7°Middle 30°Flood 50°
4 m17,031 lux / 0.5 m3,125 lux / 2.1 m1,734 lux / 3.7 m
5 m10,900 lux / 0.6 m2,000 lux / 2.7 m1,110 lux / 4.7 m
6 m7,569 lux / 0.7 m1,389 lux / 3.2 m771 lux / 5.6 m
Complete ARRI table. Each cell is centre illuminance / published beam diameter.

Distance Limits: ARRI’s November 2013 Compact operating instructions specifies 5 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 5–6 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use. The historical 4 m table reading is retained above for source reference only, not as an operating-distance recommendation, and excluded from the calculator.

The historical table retains all nine documented centre readings; the calculator uses only the readings within the distance limits above. Beam diameter is shown for coverage planning and does not change the exposure calculation.

Back to contents

Power and Batteries

This head uses EB 400/575, EB 575/1200, EBB 575/1200 battery, or compatible period choke ballast. Confirm lamp wattage, lamp base, ballast setting, head connector and cable as one package. The 95 V figure describes the lamp circuit, not the supply outlet.

The HMI ballast and head-cable reference separates ARRI electronic and magnetic variants. Use the selected ballast input range, rated current, power factor, frequency mode and protective-device instructions for distribution.

Back to contents

Control, Cooling and Camera Operation

The head has manual focus knobs at front and rear. Keep ventilation clear and use the ballast’s documented camera mode if it has one. Check exposure at the actual frame rate and shutter; no head-only specification guarantees flicker-free operation. Observe ARRI’s minimum clearances and let the unit cool before handling the lamp or lens assembly.

Modifiers, Rigging and the Working Package

ARRI documents 0.5 m to flammable objects, 5 m to illuminated surfaces and ±90° tilt in the 2013 instructions. Operate only with an intact Fresnel, reflector, wire guard or safety glass, lens-door latch and interlock. Keep ventilation open and cables away from the housing.

Support the head, barndoor, filter frame, cable pull and modifier as one load. Use properly rated primary support and secondary retention. A cracked lens, dull reflector, brittle internal lamp lead, heat-damaged connector or unreliable latch removes the head from service.

Back to contents

Alternatives and Related Fixtures

FixtureWhy compare it
ARRI True Blue D5A later 575 W daylight Fresnel with current family documentation.
ARRI M8A lensless 800 W MAX-reflector head for greater throw and a different beam character.
ARRI Compact familyCompare the surrounding wattages, lens sizes, support loads and ballast packages.
Related fixtures

Back to contents

What People Are Saying

Videos

The ARRI Compact operating instructions show the manual-focus controls, front retainer and safety features and include a separate 575 W specifications row. For the standard non-Theater head, use the matching Daylight Compact brochure table. The common manual does not make Theater-model photos or photometry interchangeable.

Rental and Used-Fixture Checks

Read the nameplate before accepting the package. Record the exact head variant, lamp, ballast model, connector and cable. Inspect lamp contacts, lens, reflector, focus travel, interlock, yoke, mount and accessory retention, then test cold start, stable output, hot restrike and the intended camera mode.

Documentation and Specifications

Official ARRI Compact archive · ARRI Daylight Compact brochure · ARRI operating instructions · ARRI Compact certification.

Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.

Back to contents