Last Updated 21 hours ago
Compact 575 Overview



The ARRI Compact 575 is a 575 W daylight HMI Fresnel with a 130 mm lens and a published 7°–50° focus range. It uses a G22 single-ended lamp.
The head weighs roughly 7.5 kg before doors, cable or ballast. It is not the ARRISUN 5 PAR or the ARRI D5. Order an approved 575 W ballast and the cable that fits the particular generation of head.
- Fixture Type Compact daylight Fresnel
- Power 575 W G22 HMI + compatible ballast
- Colour Temperature 6,000 K Nominal daylight lamp class; actual CCT depends on the lamp and its condition.
- Weight 7.5 kg in 2013 instructions; 7.25 kg in 2005 brochure
- Beam Angle 7° to 50° published focus; 130 mm Fresnel
- IP Rating IP23 Check the actual head and complete connected system; not waterproof. Read the IP Rating Guide.
Compact 575 Specifications
| Specification | Details |
|---|---|
| Model / ordering reference | L0.73770.SB / L0.73775.B manual versions |
| Lamp / base | HMI 575 W/SE / G22 |
| Nominal lamp circuit | 95 V; ballast mains input is separate |
| Nominal colour | 6,000 K daylight class in the period ARRI brochure |
| Optic | 130 mm Fresnel lens |
| Published focus range | 7° to 50° |
| Dimensions (H × W × L) | 314 × 290 × 272 mm |
| Head weight | 7.25 kg in the 2005 brochure; 7.5 kg in the 2013 instructions |
| Mount | 28 mm junior spigot |
| Documented ballast families | EB 400/575, EB 575/1200, EBB 575/1200 battery, or compatible period choke ballast |
| Protection | Class I / IP23 |
| Safety distances / tilt | 0.5 m to flammable objects, 5 m to illuminated surfaces and ±90° tilt in the 2013 instructions. |
| Status | Discontinued |
The Lexicon divides lamp wattage by a convenient supply voltage. That is not the lamp circuit and does not establish ballast input current. Plan distribution from the actual ballast nameplate and manual.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
| Strengths | Limitations |
|---|---|
| Focusable, even daylight field; complete manufacturer spot, middle and flood data; conventional accessories and serviceable construction. | Separate ballast and high-voltage head cable; hot single-ended discharge lamp; dated connector variants; discontinued head and accessory system. |
Practical Uses
| Setup | Working approach |
|---|---|
| Hard daylight key | Select focus for the required pool, then meter the subject rather than relying on centre output alone. |
| Window or exterior fill | Use spot or middle when throw matters and control spill with the retained barndoor. |
| Bounce or diffusion | Use flood to cover the modifier evenly, then meter after transmission or reflection loss. |
The front and rear focus controls move the source through the Fresnel system. Do not use the lens door, accessory latch or cable as a handling point.
Output and Colour
The period ARRI Daylight Compact brochure publishes all nine measurements for this exact 575 W head. ARRI states that the data follow ESTA practice and are normalised to nominal lamp lumens.
| Distance | Spot 7° | Middle 30° | Flood 50° |
|---|---|---|---|
| 4 m | 17,031 lux / 0.5 m | 3,125 lux / 2.1 m | 1,734 lux / 3.7 m |
| 5 m | 10,900 lux / 0.6 m | 2,000 lux / 2.7 m | 1,110 lux / 4.7 m |
| 6 m | 7,569 lux / 0.7 m | 1,389 lux / 3.2 m | 771 lux / 5.6 m |
Distance Limits: ARRI’s November 2013 Compact operating instructions specifies 5 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 5–6 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use. The historical 4 m table reading is retained above for source reference only, not as an operating-distance recommendation, and excluded from the calculator.
The historical table retains all nine documented centre readings; the calculator uses only the readings within the distance limits above. Beam diameter is shown for coverage planning and does not change the exposure calculation.
Power and Batteries
This head uses EB 400/575, EB 575/1200, EBB 575/1200 battery, or compatible period choke ballast. Confirm lamp wattage, lamp base, ballast setting, head connector and cable as one package. The 95 V figure describes the lamp circuit, not the supply outlet.
The HMI ballast and head-cable reference separates ARRI electronic and magnetic variants. Use the selected ballast input range, rated current, power factor, frequency mode and protective-device instructions for distribution.
Control, Cooling and Camera Operation
The head has manual focus knobs at front and rear. Keep ventilation clear and use the ballast’s documented camera mode if it has one. Check exposure at the actual frame rate and shutter; no head-only specification guarantees flicker-free operation. Observe ARRI’s minimum clearances and let the unit cool before handling the lamp or lens assembly.
Modifiers, Rigging and the Working Package
ARRI documents 0.5 m to flammable objects, 5 m to illuminated surfaces and ±90° tilt in the 2013 instructions. Operate only with an intact Fresnel, reflector, wire guard or safety glass, lens-door latch and interlock. Keep ventilation open and cables away from the housing.
Support the head, barndoor, filter frame, cable pull and modifier as one load. Use properly rated primary support and secondary retention. A cracked lens, dull reflector, brittle internal lamp lead, heat-damaged connector or unreliable latch removes the head from service.
Alternatives and Related Fixtures
| Fixture | Why compare it |
|---|---|
| ARRI True Blue D5 | A later 575 W daylight Fresnel with current family documentation. |
| ARRI M8 | A lensless 800 W MAX-reflector head for greater throw and a different beam character. |
| ARRI Compact family | Compare the surrounding wattages, lens sizes, support loads and ballast packages. |
What People Are Saying
Field Feedback at a Glance
The 2005 ARRI brochure and 2013 ARRI operating instructions document the original Compact 575 head. The points here are model-specific working characteristics and limits, not independently reported owner reactions.
What worked
- Useful hard-daylight focus range: ARRI records 10,900 lux at 7° spot and a 4.7 m beam diameter in 50° flood at 5 m.
- Front and rear manual focus let you adjust the beam from either side of the housing without disturbing the mounted front accessory.
- A period battery option is documented: the ARRI EBB 575/1200 is a separate matching ballast, not an onboard battery input.
Drawbacks to plan for
- Keep the 4 m brochure figures out of operating estimates: the 2013 head instructions require at least 5 m to illuminated surfaces.
- The 95 V lamp circuit is not a source or battery specification. Verify the head lead, ballast and actual ballast input.
- Inspect the lens door, guard and interlock on a used head. ARRI requires complete enclosure and intact optics because the lamp emits heat and UV.
Videos
The ARRI Compact operating instructions show the manual-focus controls, front retainer and safety features and include a separate 575 W specifications row. For the standard non-Theater head, use the matching Daylight Compact brochure table. The common manual does not make Theater-model photos or photometry interchangeable.
Rental and Used-Fixture Checks
Read the nameplate before accepting the package. Record the exact head variant, lamp, ballast model, connector and cable. Inspect lamp contacts, lens, reflector, focus travel, interlock, yoke, mount and accessory retention, then test cold start, stable output, hot restrike and the intended camera mode.
Documentation and Specifications
Official ARRI Compact archive · ARRI Daylight Compact brochure · ARRI operating instructions · ARRI Compact certification.
Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.
Browse ARRI lights · HMI lights · all equipment.