ARRI X40/25

Last Updated 22 hours ago

ARRI X40/25 Overview

ARRI X40/25 daylight open-face fixture
ARRI X40/25 open-face broad light in Tree Digital Studio rental inventory
X40/25 rental headActual X series broad light. Do not confuse it with the AS 40/25 PAR or the X40/25 Theater body. Photo: Tree Digital Studio.
ARRI EB Universal 2.5/4 ballast
2.5/4 kW ballastExample ballast from the documented 2.5/4 kW family; verify cable and connectors against the actual head. Photo: BarnDoor Lighting.

The ARRI X40/25 is a single-ended HMI broad light that accepts either a 2.5 kW or a 4 kW lamp. Its silver reflector creates an approximately 128° fixed field for lighting large flat surfaces, bounces or diffusion.

It does not focus like a Fresnel. The dual wattage means a choice of lamp and matched ballast configuration, not a continuous 2.5–4 kW setting. The Theater version adds a different front accessory assembly.

Detail photo

  • Colour Temperature 6,000 K Nominal daylight lamp class; actual CCT depends on the lamp and its condition.
  • Weight 18 kg head (manual); 22 kg in period brochure
  • Beam Angle Approx. 128° fixed flood; silver/black reflector
  • IP Rating IP23 Check the actual head and complete connected system; not waterproof. Read the IP Rating Guide.
  • Power 2,500 or 4,000 W G38 HMI + matched ballast
  • Fixture Type Standard broad open-face HMI flood

Jump to Output Calculator ↓

X40/25 Specifications

SpecificationDetails
Lamp / base2,500 W/SE or 4,000 W/SE metal-halide / G38
Nominal lamp circuits115 V at 2,500 W; 200 V at 4,000 W
Nominal colour6,000 K daylight lamp class
OpticInterchangeable silver or black reflector
Published beamApproximately 128°
Head weight18 kg in the operating manual; older brochure lists 22 kg
Brochure dimensions635 × 590 × 290 mm
Mount28 mm junior spigot
Published ballastEB 2.5/4 kW family; confirm lamp setting and connector
Clearances4.0 m to illuminated surfaces; 1.0 m to flammable material
Thermal / tilt200°C maximum surface; 45°C ambient; ±90° tilt
StatusDiscontinued in 2017
ARRI operating manual, ARRI X brochure and ARRI lamp documentation.

The Lexicon row shows a 4,000 W lamp but the exact model is dual-wattage. Its listed 120 V arithmetic does not match the 4,000 W lamp circuit and cannot replace the ballast input specification.

X40/25 Output Calculator

Compare ARRI’s clear and frosted glass tests for the standard X40/25 (L1.82410.B) with the GE 4,000 W SE HR lamp. The ARRI IES/LDT photometry archive gives the on-axis intensity. Lux and foot-candles below are distance-based estimates, not measurements at those throws. The archive does not identify a 2,500 W, black reflector or Theater configuration.

At 5 m (16.4 ft), the on-axis estimate is 2,852 lx with the clear glass and 3,072 lx with the frosted glass. The reference table works without JavaScript.

Published intensity data and calculation method

Lux = candela ÷ distance in metres squared. Foot-candles = lux ÷ 10.7639. The camera estimate uses f-number = √(lux × ISO × shutter time ÷ meter reference). The small digit is tenths of a stop, not a T-stop.

This calculator starts at 5 m. The result is an inverse-square estimate along the optical axis, not the brightest point, an average over the field or a minimum safe placement. Follow the fixture manual and meter the practical setup. The higher on-axis figure with frost does not establish greater total output.

4,000 W test setupOn-axis intensityEstimate at 5 mEstimate at 10 m
Clear glass (127.0°)71,288 cd2,851.52 lx712.88 lx
Frosted glass (126.4°)76,798 cd3,071.92 lx767.98 lx

Strengths and Limitations

StrengthsLimitations
Dual 2.5/4 kW lamp support; very wide compensated field; interchangeable reflector character.The brochure table does not identify which lamp produced its photometry; heavy ballast and cable package; discontinued.
Working characteristics

Back to contents

Practical Uses

SetupWorking approach
Large backingUse the silver reflector for a broad, even wash where a narrower PAR would require multiple overlaps.
Large bounceFill the bounce rather than chasing centre intensity; select lamp wattage from the required field and distribution.
Hard direct effectFit the approved black reflector for the arc-light-style shadow character.
Lighting applications

The 2.5 kW and 4 kW configurations must be treated as separate approved systems. Do not change only the ballast setting while leaving an incompatible lamp installed.

Back to contents

Output and Colour

The ARRI X brochure prints 1,750 lux at 6 m, 984 lux at 8 m and 630 lux at 10 m for the X40/25 wide field. The table sits under a dual-wattage heading and does not state which lamp produced those readings.

DistancePublished centre illuminanceField note
6 m1,750 luxDual-wattage table; test lamp not identified
8 m984 luxDual-wattage table; test lamp not identified
10 m630 luxDual-wattage table; test lamp not identified
ARRI legacy brochure values. The source does not identify the 2,500 W or 4,000 W test lamp.

ARRI published a separate photometric archive that identifies the 4,000 W GE lamp and clear/frosted glass. The calculator uses only that archive. The figures in the table immediately above stay separate because the brochure does not identify its lamp or glass.

The three brochure readings follow inverse-square scaling, but that does not resolve the lamp or glass. Do not treat them as a comparison between 2.5 kW and 4 kW.

Back to contents

Power and Batteries

Use an approved 2.5/4 kW ballast, the correct selected wattage, an approved G38 lamp and the matching head cable. ARRI notes that switchable heads are wired as 4 kW heads when an older 2.5 kW choke-ballast adapter is involved.

The lamp voltages are not mains-input figures. The head has no direct battery input. Distribution must follow the actual ballast input plate and manual. Verify connector type, ballast generation, permitted cable run, protective earth and high-speed mode before the head is rigged.

Back to contents

Control, Cooling and Camera Operation

The X40/25 has an on/off switch, hour counter and safety switch. Its colour-coded adjustment wheel sets the head to the correct lamp length for the approved 2.5 or 4 kW lamp; it is not a beam-focus or colour-temperature control. See the head diagram and parts key.

Dimming and flicker behaviour depend on the ballast. After the lamp settles, test the planned frame rate and shutter on the assembled package. Check noise at the microphone position and leave the head and ballast ventilation paths open.

Back to contents

Modifiers, Rigging and the Working Package

ARRI gives 4.0 m to illuminated surfaces and 1.0 m around the head to flammable material. The required safety glass and reflector must be complete; the lamp enclosure interlock is not to be bypassed.

A head in the 18–22 kg documentation range plus barndoor and cable pull requires appropriate junior support and handling. Keep ventilation clear and inspect the yoke, brake, spigot, cable, glass and reflector before use.

Back to contents

Alternatives and Related Fixtures

Similar name, different optics: The ARRI AS 40/25 is the interchangeable-lens PAR, rather than the wide X-series open-face flood.

FixtureWhy compare it
ARRI M8A lensless MAX-reflector head for a more concentrated daylight beam.
ARRI True Blue D12A conventional daylight Fresnel when focusable beam control matters more than very wide flood coverage.
ARRI M18A 1.2/1.8 kW MAX head for greater throw without a spread-lens kit.
Related fixtures

Back to contents

What People Are Saying

Field Feedback at a Glance

These practical takeaways are based on ARRI’s original X brochure and the operating manual, not independent owner reviews.

What works

  • The head supports approved 2,500 W and 4,000 W single-ended lamps with the corresponding ballast setup, useful when the job has different power or coverage requirements.
  • The silver reflector’s broad field suits large flat backings. ARRI’s separate 4 kW file identifies the clear and frosted glass configurations for those comparisons.
  • ARRI lists a four-leaf door set, frosted safety glass and black reflector specific to the production head; check model numbers instead of assuming the Theatre front assembly is interchangeable.

Drawbacks to plan for

  • The brochure’s dual-wattage table does not name the lamp or glass. Its numbers cannot be used to compare 2.5 kW with 4 kW; the page’s archive-based calculation is 4 kW only.
  • ARRI specifies 4 m (13.1 ft) to illuminated areas and 1 m (3.3 ft) to flammables. The nominal lamp circuit is also different at the two wattages; it is not ballast mains input.
  • The manual lists an 18 kg head while the brochure lists 22 kg. Weigh the actual rental with its glass, doors and cable before sizing the support.

Back to contents

Videos and Operating Reference

The ARRI X-Series operating instructions describe the X40/25’s lamp-length adjustment, glass checks and approved operating setup. Use the production X40/25 instructions, not the Theatre, ARRISUN AS40/25 or M40 documentation.

Back to contents

Rental and Used-Fixture Checks

Record which lamp, ballast, connector and reflector are actually supplied. Inspect lamp contacts for heat damage, verify the selector and cable package, test stable operation at the chosen wattage, and do not accept an unlabeled dual-wattage combination on assumption.

Documentation and Specifications

Official discontinued-series page · ARRI X brochure · ARRI X operating manual · ARRI approved lamps · ARRI head cables.

Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.

Back to contents