ARRI X60

Last Updated 22 hours ago

ARRI X60 Overview

ARRI X60 daylight open-face fixture
ARRI X60 open face HMI head from Electric Sun rental
X60 lampheadOpen-face X60 in a specialist film-lighting inventory. Photo: Electric Sun.
ARRI X60 kit with external ballast and head cable
Lamp and ballast kitARRI’s X60 HMI kit with its separate electronic ballast and support accessories. Photo: B&H.

The ARRI X60 is a 6 kW single-ended HMI broad light. Its silver reflector has an approximately 128° compensated field for lighting large scenic surfaces, bounces or diffusion frames from a relatively short throw.

It is an open-face broad light, not a focusable Fresnel or a PAR. Order the correct separate 6 kW ballast and matched head cable; the kit can also include barndoors and a frosted diffuser.

Detail photo

  • Colour Temperature 6,000 K Nominal daylight lamp class; actual CCT depends on the lamp and its condition.
  • Weight 32 kg head (manual); 35.2 kg in period brochure
  • Beam Angle Approx. 128° fixed flood; silver/black reflector
  • IP Rating IP23 Check the actual head and complete connected system; not waterproof. Read the IP Rating Guide.
  • Power 6,000 W G38 HMI + matched ballast
  • Fixture Type Broad open-face HMI flood

Jump to Output Calculator ↓

X60 Specifications

SpecificationDetails
Lamp / base6,000 W single-ended metal-halide / G38
Nominal lamp circuit123 V; ballast input is separate
Nominal colour6,000 K daylight lamp class
OpticInterchangeable silver or black reflector
Published beamApproximately 128°
Head weight32 kg in the operating manual; older brochure lists 35.2 kg
Brochure dimensions840 × 810 × 400 mm
Mount28 mm junior spigot
Published ballasts6 kW or 6/12 kW period systems; connector-specific
Clearances4.0 m to illuminated surfaces; 1.5 m to flammable material
Thermal / tilt180°C maximum surface; 45°C ambient; ±90° tilt
StatusDiscontinued in 2017
ARRI operating manual and ARRI X brochure.

The Lexicon identifies the 6 kW head but calculates from a 208 V supply. That arithmetic does not describe the 123 V lamp circuit or the actual ballast input.

Output Calculator

Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.

Camera Settings

If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.

F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.

How the exposure estimate works

N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.

Distance estimates and comparisons

Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.

Strengths and Limitations

StrengthsLimitations
Large, broad and even 6 kW daylight field; useful for scenic coverage and large modifiers; reflector character can be changed.Large hot head, heavy cable and ballast package; no focus range; long safety distances; discontinued.
Working characteristics

Back to contents

Practical Uses

SetupWorking approach
Large scenic backingUse the silver reflector to cover a wide surface with fewer overlaps than a narrow source.
Large bounceFill the bounce evenly and meter its useful area after spill control.
Diffusion frameSet the head far enough back for coverage while respecting the four-metre illuminated-surface minimum.
Lighting applications

The wide source can reduce hot spots on modifiers, but the direct head still casts hard shadows. Apparent softness depends on the illuminated modifier or surface.

Back to contents

Output and Colour

The ARRI X brochure publishes the complete three-distance table for the single 6,000 W X60 configuration.

DistanceCentre illuminancePublished field diameter
5 m4,248 lux20.5 m
10 m1,062 lux41 m
15 m472 lux61.5 m
ARRI 6,000 W silver-reflector data, normalised to nominal lamp lumens.

Distance Limits: ARRI’s January 2007 X-series operating manual specifies 4 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 5–15 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use.

All three manufacturer readings are retained within the restricted calculator range. Use this control only for the identified silver reflector and a serviceable 6 kW package.

Back to contents

Power and Batteries

The X60 requires an approved 6 kW or 6/12 kW ballast and the connector-matched heavy head cable. The 6,000 W lamp rating and 123 V lamp circuit are not the ballast mains-input specification. The X60 has no direct battery input.

Use the actual ballast line-power and input-voltage range for distribution. Confirm phase arrangement where applicable, protective earth, connector condition, cable length and camera mode. A generic 208 V division is not enough.

Back to contents

Control, Cooling and Camera Operation

The X60 provides a head switch, hour counter and safety switch. Current control, dimming and any low-noise or flicker-related mode live on the selected ballast. ARRI lists both EB 6000 and EB 6/12 options; the ARRI ballast archive distinguishes their model numbers and manuals.

Test the assembled package with the lamp at stable output at the intended camera frame rate and shutter setting. For a quiet scene, check audible lamp and ballast noise from the actual mic position. Keep cooling paths open.

Back to contents

Modifiers, Rigging and the Working Package

ARRI gives 4.0 m to illuminated surfaces and 1.5 m around the head to flammable objects. Keep both safety-glass layers and the reflector installed, and do not bypass the interlock.

The head alone is 32 kg in the operating manual, before barndoor, cable pull and modifier forces. Use appropriate handling, heavy support and secondary retention. Keep ventilation and cable clearance from the hot housing.

Back to contents

Alternatives and Related Fixtures

FixtureWhy compare it
ARRI X40/25A smaller dual-wattage member of the same wide-reflector family.
ARRI Compact 6000 PlusA 6 kW focusable daylight Fresnel rather than a 128° broad light.
ARRI M90A 6/9 kW lensless MAX head for greater throw.
Related fixtures

Back to contents

What People Are Saying

Field Feedback at a Glance

These practical takeaways are based on ARRI’s original X brochure and the operating manual, not independent owner reviews.

What works

  • The silver reflector’s wide field is designed for covering large scenery or backing; ARRI publishes 4,248 lux at 5 m across a 20.5 m field in the stated 6 kW configuration.
  • At 10 m the brochure still lists 1,062 lux at centre, useful for estimating whether a more distant large backing can be reached before modifier losses.
  • ARRI specifies X60 four-leaf doors and an optional black reflector; the silver and black treatments give distinct use cases without implying identical output.

Drawbacks to plan for

  • The manual requires 4 m (13.1 ft) to illuminated areas and 1.5 m (4.9 ft) to flammables. This is not a short-clearance light despite the broad optics.
  • The head weighs 32 kg in the manual and 35.2 kg in the brochure before resolving actual package hardware. Plan the complete suspended or stand load and use correctly rated support.
  • The approved lamp is a 6 kW single-ended G38, not one of the X40/25 lamps. Verify the 6 kW-rated ballast and matching cable/connectors; the lamp-circuit voltage is not the mains input.

Back to contents

Videos and Operating Reference

Use the illustrated ARRI X-Series operating manual to locate the secondary safety attachment, glass frame, safety switch and hours counter. The illustration covers the family; use the X60 row in the manual for model-specific clearances and operating limits.

Back to contents

Rental and Used-Fixture Checks

Confirm the X60, silver or black reflector, ballast model, connector and cable package. Inspect both safety glasses, reflector finish, lamp holder, interlock, yoke, spigot and high-current contacts. Test cold start, stable running and camera settings.

Documentation and Specifications

Official discontinued-series page · ARRI X brochure · ARRI X operating manual · ARRI approved lamps · ARRI head cables.

Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.

Back to contents