Last Updated 22 hours ago
ARRI X60 Overview



The ARRI X60 is a 6 kW single-ended HMI broad light. Its silver reflector has an approximately 128° compensated field for lighting large scenic surfaces, bounces or diffusion frames from a relatively short throw.
It is an open-face broad light, not a focusable Fresnel or a PAR. Order the correct separate 6 kW ballast and matched head cable; the kit can also include barndoors and a frosted diffuser.
- Colour Temperature 6,000 K Nominal daylight lamp class; actual CCT depends on the lamp and its condition.
- Weight 32 kg head (manual); 35.2 kg in period brochure
- Beam Angle Approx. 128° fixed flood; silver/black reflector
- IP Rating IP23 Check the actual head and complete connected system; not waterproof. Read the IP Rating Guide.
- Power 6,000 W G38 HMI + matched ballast
- Fixture Type Broad open-face HMI flood
X60 Specifications
| Specification | Details |
|---|---|
| Lamp / base | 6,000 W single-ended metal-halide / G38 |
| Nominal lamp circuit | 123 V; ballast input is separate |
| Nominal colour | 6,000 K daylight lamp class |
| Optic | Interchangeable silver or black reflector |
| Published beam | Approximately 128° |
| Head weight | 32 kg in the operating manual; older brochure lists 35.2 kg |
| Brochure dimensions | 840 × 810 × 400 mm |
| Mount | 28 mm junior spigot |
| Published ballasts | 6 kW or 6/12 kW period systems; connector-specific |
| Clearances | 4.0 m to illuminated surfaces; 1.5 m to flammable material |
| Thermal / tilt | 180°C maximum surface; 45°C ambient; ±90° tilt |
| Status | Discontinued in 2017 |
The Lexicon identifies the 6 kW head but calculates from a 208 V supply. That arithmetic does not describe the 123 V lamp circuit or the actual ballast input.
Output Calculator
Select the published setup and a manufacturer distance, or enter a custom throw where supported. The results describe centre-beam output, not the brightness across the whole beam.
Camera Settings
If the calculator does not load, use the published photometric table or source on this page. JavaScript is required.
F-stop is a planning estimate, not a meter reading. It uses direct, on-axis illuminance and includes only the optics and diffusion named in the selected setup. Meter on set to account for lens transmission, filters, added diffusion, bounce, dimming and ambient light.
How the exposure estimate works
N = √(E × ISO × t / C), where E is illuminance in lux and t = shutter angle ÷ (360 × fps). The default C = 340 is a dome reference; C = 250 is a flat reference. These are calibration constants, not a measured T-stop. A small nonzero digit is tenths of a stop above the displayed full stop.
Distance estimates and comparisons
Published points are used as given. Between published points the calculator fits a curve through the two nearest readings. Outside those points it uses the inverse-square law only when the fixture’s dataset permits it. Distances outside a configuration’s supported range are reported separately. Comparisons use one shared distance and camera setup; equal lux does not imply equal coverage.
View published readings for the selected configuration
Strengths and Limitations
| Strengths | Limitations |
|---|---|
| Large, broad and even 6 kW daylight field; useful for scenic coverage and large modifiers; reflector character can be changed. | Large hot head, heavy cable and ballast package; no focus range; long safety distances; discontinued. |
Practical Uses
| Setup | Working approach |
|---|---|
| Large scenic backing | Use the silver reflector to cover a wide surface with fewer overlaps than a narrow source. |
| Large bounce | Fill the bounce evenly and meter its useful area after spill control. |
| Diffusion frame | Set the head far enough back for coverage while respecting the four-metre illuminated-surface minimum. |
The wide source can reduce hot spots on modifiers, but the direct head still casts hard shadows. Apparent softness depends on the illuminated modifier or surface.
Output and Colour
The ARRI X brochure publishes the complete three-distance table for the single 6,000 W X60 configuration.
| Distance | Centre illuminance | Published field diameter |
|---|---|---|
| 5 m | 4,248 lux | 20.5 m |
| 10 m | 1,062 lux | 41 m |
| 15 m | 472 lux | 61.5 m |
Distance Limits: ARRI’s January 2007 X-series operating manual specifies 4 m minimum to illuminated surfaces. This control is conservatively restricted to the retained published distances, 5–15 m; values between those distances are interpolations, not additional manufacturer measurements. No output is extrapolated outside that interval. Follow the instructions and nameplate for the exact head in use.
All three manufacturer readings are retained within the restricted calculator range. Use this control only for the identified silver reflector and a serviceable 6 kW package.
Power and Batteries
The X60 requires an approved 6 kW or 6/12 kW ballast and the connector-matched heavy head cable. The 6,000 W lamp rating and 123 V lamp circuit are not the ballast mains-input specification. The X60 has no direct battery input.
Use the actual ballast line-power and input-voltage range for distribution. Confirm phase arrangement where applicable, protective earth, connector condition, cable length and camera mode. A generic 208 V division is not enough.
Control, Cooling and Camera Operation
The X60 provides a head switch, hour counter and safety switch. Current control, dimming and any low-noise or flicker-related mode live on the selected ballast. ARRI lists both EB 6000 and EB 6/12 options; the ARRI ballast archive distinguishes their model numbers and manuals.
Test the assembled package with the lamp at stable output at the intended camera frame rate and shutter setting. For a quiet scene, check audible lamp and ballast noise from the actual mic position. Keep cooling paths open.
Modifiers, Rigging and the Working Package
ARRI gives 4.0 m to illuminated surfaces and 1.5 m around the head to flammable objects. Keep both safety-glass layers and the reflector installed, and do not bypass the interlock.
The head alone is 32 kg in the operating manual, before barndoor, cable pull and modifier forces. Use appropriate handling, heavy support and secondary retention. Keep ventilation and cable clearance from the hot housing.
Alternatives and Related Fixtures
| Fixture | Why compare it |
|---|---|
| ARRI X40/25 | A smaller dual-wattage member of the same wide-reflector family. |
| ARRI Compact 6000 Plus | A 6 kW focusable daylight Fresnel rather than a 128° broad light. |
| ARRI M90 | A 6/9 kW lensless MAX head for greater throw. |
What People Are Saying
Field Feedback at a Glance
These practical takeaways are based on ARRI’s original X brochure and the operating manual, not independent owner reviews.
What works
- The silver reflector’s wide field is designed for covering large scenery or backing; ARRI publishes 4,248 lux at 5 m across a 20.5 m field in the stated 6 kW configuration.
- At 10 m the brochure still lists 1,062 lux at centre, useful for estimating whether a more distant large backing can be reached before modifier losses.
- ARRI specifies X60 four-leaf doors and an optional black reflector; the silver and black treatments give distinct use cases without implying identical output.
Drawbacks to plan for
- The manual requires 4 m (13.1 ft) to illuminated areas and 1.5 m (4.9 ft) to flammables. This is not a short-clearance light despite the broad optics.
- The head weighs 32 kg in the manual and 35.2 kg in the brochure before resolving actual package hardware. Plan the complete suspended or stand load and use correctly rated support.
- The approved lamp is a 6 kW single-ended G38, not one of the X40/25 lamps. Verify the 6 kW-rated ballast and matching cable/connectors; the lamp-circuit voltage is not the mains input.
Videos and Operating Reference
Use the illustrated ARRI X-Series operating manual to locate the secondary safety attachment, glass frame, safety switch and hours counter. The illustration covers the family; use the X60 row in the manual for model-specific clearances and operating limits.
Rental and Used-Fixture Checks
Confirm the X60, silver or black reflector, ballast model, connector and cable package. Inspect both safety glasses, reflector finish, lamp holder, interlock, yoke, spigot and high-current contacts. Test cold start, stable running and camera settings.
Documentation and Specifications
Official discontinued-series page · ARRI X brochure · ARRI X operating manual · ARRI approved lamps · ARRI head cables.
Product photograph: ARRI product photograph reproduced in the Lexicon Carbone source document for model identification.
Browse ARRI lights · HMI lights · all equipment.